Generic build for other GE sites: no WJ data, one shopfloor type, Windows USB builder

Everything West Jefferson specific moved out to a separate repo
(pxe-site-wj): NTLARS/UDC/heat-treat backups keyed by WJ machine numbers,
CMM and Wax/Trace bay lists, WJ OpenText profiles, site-config.json, the
WJ preinstall list, and the WJ shopfloor PC types (Collections,
NoCollections, Common, Keyence, CMM, Genspect, HeatTreat, Wax/Trace,
Display, PartMarker) with GE-Enforce, machine numbers and the desktop
layout. The part-marker bench tools moved to their own repo. Dead
scripts removed: build-proxmox-iso, deploy-bios, sync_hardware_models,
mirror-from-gold, pull-bios, startnet-template.cmd.

Shopfloor is one generic type, gea-shopfloor-standard, with today's
timing:
- PPKG at first logon (unattend Order 10, unchanged).
- Install-AppList.ps1 runs C:\PreInstall\preinstall.json during setup.
- A new SYSTEM task, GE Shopfloor Post-PPKG, runs postppkg.json once
  after the post-PPKG reboot. It also clears AutoLogonCount after the
  ShopFloor handover (the Users-level monitor can be denied that HKLM
  write) and removes the Intune Sync task when done.
- Both lists ship empty. A site adds entries and installers.
- WinPE choice 3 goes straight to the PPKG menu. Staging, fetch and heal
  carry only the generic payload. The webapp's shopfloor sub-menu editor
  is gone, and the imaging tiles name the new stages.
- The playbook deploys the empty lists only if missing. It now deploys
  the PowerShell 7 MSI the shopfloor unattend installs, which it never
  did before.

Blancco site settings move into the webapp (Updates > Blancco releases):
business location, licensing Wi-Fi SSID and password. They are rendered
into the served preferences.xml and applied to every staged release, and
are seeded from site-vars (site_name, blancco_wifi_ssid,
blancco_wifi_password) only while none exist. The repo XML carries no
site values; the plaintext Wi-Fi password is gone from it.

New site_name and site_timezone settings: report and evidence-pack site
name, server clock and webapp time zone. No more West Jefferson defaults
in webapp/config.py or the dashboard title. Sync-BPRT.ps1 gets the
server address filled in at download instead of WJ's GE address.

USB on Windows:
- scripts/Build-PxeUsb.ps1 runs the same checks as build-usb.sh. It
  writes one FAT32 CIDATA partition (ISO files plus patched grub.cfg plus
  payload) with diskpart and reads every file back by SHA-256.
- Tested with Windows PowerShell 5.1 in the win11 VM, and the layout
  installs and first-boots in the pxetest VM.
- scripts/stage-usb-share.sh stages the build folder on a share.
- site-content/ is optional for both builders.

KB docs/kb/How_To_Deploy_PXE_Server_New_Site.html: new-site deployment,
Windows only, with a site-vars.yml guide.

Checks: webapp tests pass (5 suites); the unattend lint and playbook
syntax checks pass; every .ps1 parses; there are no WJ hosts, IPs, names
or PC types in playbook/, webapp/, scripts/ or autoinstall/.
This commit is contained in:
cproudlock
2026-10-16 20:37:22 -04:00
parent b11e678297
commit 04db6d6605
710 changed files with 3113 additions and 82414 deletions

View File

@@ -1,23 +0,0 @@
@echo off
REM Install-AcroReader.cmd - Install Adobe Acrobat Reader DC + DC update patch
REM
REM Two-step install: base MSI with enterprise transform, then DC update patch.
REM Same version as the GEA-Engineering image (specialize pass Orders 22-23).
REM Files staged by startnet.cmd from enrollment share to C:\PreInstall\installers\adobe\.
echo Installing Adobe Acrobat Reader DC...
msiexec /i "%~dp0AcroRead.msi" TRANSFORMS="%~dp0AcroRead.mst" /quiet /norestart
if %errorlevel% neq 0 if %errorlevel% neq 3010 (
echo Acrobat Reader MSI failed with exit code %errorlevel%
exit /b %errorlevel%
)
echo Applying Adobe Reader DC update patch...
msiexec /p "%~dp0AcroRdrDCUpd2500120531.msp" /quiet /norestart
if %errorlevel% neq 0 if %errorlevel% neq 3010 (
echo Acrobat Reader patch failed with exit code %errorlevel%
exit /b %errorlevel%
)
echo Adobe Acrobat Reader DC installed successfully.
exit /b 0

View File

@@ -1,43 +0,0 @@
@echo off
REM Install-KioskApp.cmd - Install Lobby Display or Dashboard kiosk app
REM
REM Reads C:\Enrollment\display-type.txt to determine which app to install.
REM Only runs on Display PCs (PCTypes filter in preinstall.json).
REM Both installers live alongside this script in the staged display\ subtree.
set "TYPEFILE=C:\Enrollment\display-type.txt"
if not exist "%TYPEFILE%" (
echo No display-type.txt found - skipping kiosk app install.
exit /b 0
)
set /p DISPLAYTYPE=<"%TYPEFILE%"
if /i "%DISPLAYTYPE%"=="Lobby" (
set "INSTALLER=%~dp0GEAerospaceLobbyDisplaySetup.exe"
set "APPNAME=Lobby Display"
) else if /i "%DISPLAYTYPE%"=="Dashboard" (
set "INSTALLER=%~dp0GEAerospaceDashboardSetup.exe"
set "APPNAME=Dashboard"
) else (
echo Unknown display type: %DISPLAYTYPE%
exit /b 1
)
if not exist "%INSTALLER%" (
echo %APPNAME% installer not found: %INSTALLER%
exit /b 1
)
echo Installing %APPNAME%...
"%INSTALLER%" /VERYSILENT /SUPPRESSMSGBOXES /NORESTART /LOG="C:\Logs\PreInstall\%APPNAME%-install.log"
set EXITCODE=%errorlevel%
if %EXITCODE% equ 0 (
echo %APPNAME% installed successfully.
) else (
echo %APPNAME% exited with code %EXITCODE%.
)
exit /b %EXITCODE%

View File

@@ -1,46 +0,0 @@
@echo off
REM Install-Drivers.cmd - Adds bundled INF driver packages to the Windows driver store
REM via pnputil. Runs from C:\PreInstall\installers\drivers\ where each vendor
REM subdir (prolific\, startech\) sits alongside this script. /subdirs walks into
REM them so one call covers every bundled driver.
REM
REM Writes C:\ProgramData\PXEDrivers\drivers-installed.marker on success so the
REM preinstall runner's File DetectionMethod can skip re-runs.
setlocal
set LOGDIR=C:\Logs\PreInstall
set LOG=%LOGDIR%\Install-Drivers.log
set MARKER_DIR=C:\ProgramData\PXEDrivers
set MARKER=%MARKER_DIR%\drivers-installed.marker
if not exist "%LOGDIR%" mkdir "%LOGDIR%"
if not exist "%MARKER_DIR%" mkdir "%MARKER_DIR%"
echo ================================================================ >> "%LOG%"
echo [%date% %time%] Install-Drivers session start >> "%LOG%"
echo Source dir: %~dp0 >> "%LOG%"
echo ================================================================ >> "%LOG%"
REM pnputil /add-driver with /subdirs recurses into vendor subdirs. /install
REM binds the driver to any matching hardware present now; drivers without a
REM matching device still land in the driver store and bind on plug-in later.
pnputil.exe /add-driver "%~dp0*.inf" /subdirs /install >> "%LOG%" 2>&1
set RC=%ERRORLEVEL%
echo [%date% %time%] pnputil exit code: %RC% >> "%LOG%"
REM pnputil exit codes:
REM 0 success
REM 259 ERROR_NO_MORE_ITEMS - no INFs matched (treat as failure)
REM 3010 at least one driver installed, reboot recommended (treat as success)
if "%RC%"=="0" goto :ok
if "%RC%"=="3010" goto :ok
echo [%date% %time%] FAILED (exit %RC%) >> "%LOG%"
exit /b %RC%
:ok
echo [%date% %time%] SUCCESS >> "%LOG%"
echo installed %date% %time% > "%MARKER%"
exit /b 0

View File

@@ -1,38 +0,0 @@
# OpenText HostExplorer ShopFloor - install scripts
These three files are git-tracked snapshots of what lives at runtime
in `/home/camp/pxe-images/main/dependencies/opentext/`. The full
runtime tree also contains the bundled installer binaries (~106 MB
total) which are intentionally NOT in git:
```
OpenTextHostExplorer15x64.msi ~16 MB
OpenTextHostExplorer15x64.cab ~86 MB
OpenTextHostExplorer15x64_ServicePack1.msp ~4.4 MB
ShopFloorx64.mst ~20 KB
Profile/ 5 .hep connection profiles
Accessories/EB/ 6 .ebs/.ebx macros
HostExplorer/Keymap/ 2 .kmv keymaps
HostExplorer/Menu/ 2 .hmv menu layouts
W10shortcuts/ 4 .lnk public-desktop shortcuts
```
The canonical source for everything (scripts AND binaries) is
`/home/camp/pxe-images/main/dependencies/opentext/`. The files in
this dir are mirrors that exist so changes to the install logic and
the version stamp end up in git history. When editing:
1. Edit `/home/camp/pxe-images/main/dependencies/opentext/Setup-OpenText.ps1`
(or `.cmd` / `version.txt`)
2. Re-run `bash playbook/sync-preinstall.sh` to push the runtime tree
to the live PXE server
3. `cp` the changed file(s) into `playbook/preinstall/opentext/` here
so git picks up the change
4. Re-upload the changed file(s) to Azure Blob at
`prod/main/dependencies/opentext/<filename>`
To bump OpenText version: edit `version.txt` only - the value flows
through to Setup-OpenText.ps1 (which reads it at runtime), to
Install-OpenText.ps1 (the DSC wrapper, which downloads version.txt
first as a cheap detection check), and to the registry marker at
`HKLM:\SOFTWARE\GE\OpenText\Installed`.

View File

@@ -1,11 +0,0 @@
@echo off
REM Setup-OpenText.cmd - tiny launcher for Setup-OpenText.ps1
REM
REM The PXE PreInstall runner only invokes Type:MSI or Type:EXE entries from
REM preinstall.json. This .cmd lives next to Setup-OpenText.ps1 in the staged
REM opentext\ subtree and just hands off to PowerShell with bypass policy.
REM Both files end up at C:\PreInstall\installers\opentext\ via xcopy /E from
REM the WinPE staging step in startnet.cmd.
powershell -NoProfile -ExecutionPolicy Bypass -File "%~dp0Setup-OpenText.ps1"
exit /b %errorlevel%

View File

@@ -1,361 +0,0 @@
#!/usr/bin/env pwsh
# Setup-OpenText.ps1 - OpenText HostExplorer 15 SP1 ShopFloor installer + profile
# deployment, callable from both PXE PreInstall and Intune DSC paths.
#
# WHY THIS EXISTS:
# The vendor-supplied OpenText.exe (Inno Setup wrapper built by WJDT) bundles
# the install steps but its [Files] section deploys per-user content to
# {userappdata} - which resolves to SYSTEM's profile under DSC and to a single
# user under PreInstall. As a result the operator (logging in via Azure AD)
# never sees the profiles, keymaps, menus, or macros - only the installed
# binaries. This script replaces OpenText.exe entirely, doing the same install
# steps via direct msiexec calls AND fanning the per-user content out to:
# - %ProgramData%\Hummingbird\Connectivity\15.00\Shared\
# - C:\Users\Default\AppData\Roaming\Hummingbird\Connectivity\15.00\
# - Each existing user profile under C:\Users\
#
# INVOKED BY:
# - PreInstall: Setup-OpenText.cmd wrapper (because the runner only knows MSI/EXE)
# - DSC: Install-OpenText.ps1 downloads the bundled tree from blob, then
# invokes this script with -SourceDir <temp dir>
#
# DETECTION:
# Skips if HKLM:\SOFTWARE\GE\OpenText\Installed = $expectedVersion. Marker is
# written at the end of a successful run, so the runner / DSC wrapper can
# no-op on subsequent invocations.
[CmdletBinding()]
param(
# Override when invoked from a temp dir (DSC path) where the bundled files were
# just downloaded. Defaults to $PSScriptRoot, but resolved INSIDE the script body
# below - PowerShell evaluates `param([string]$X = $PSScriptRoot)` at parameter-
# binding time, when $PSScriptRoot may not yet be populated, so the default winds
# up as an empty string. Setting it in the body works because $PSScriptRoot is
# reliably populated by then.
[string]$SourceDir
)
$ErrorActionPreference = 'Stop'
if (-not $SourceDir) {
$SourceDir = $PSScriptRoot
}
# Normalize $SourceDir to a canonical absolute path. The CMD shim passes
# "%~dp0..\apps\opentext" which embeds a literal "..". msiexec / the Windows
# Installer service fail to open the package with that unresolved segment
# (exit 1619, ERROR_INSTALL_PACKAGE_OPEN_FAILED), even though every other
# .NET / PowerShell API resolves it fine. Resolve-Path collapses ".." into
# a clean drive-rooted path before any msiexec invocation.
if (Test-Path -LiteralPath $SourceDir) {
try { $SourceDir = (Resolve-Path -LiteralPath $SourceDir).ProviderPath } catch {}
}
# --- Inline site-config reader (this script runs from C:\PreInstall\installers\opentext\,
# NOT from C:\Enrollment\shopfloor-setup\, so it can't dot-source Get-PCProfile.ps1) ---
function Get-SiteConfig {
$configPath = 'C:\Enrollment\site-config.json'
if (-not (Test-Path $configPath)) { return $null }
try {
return Get-Content $configPath -Raw | ConvertFrom-Json
} catch {
return $null
}
}
# --- Logging (set up FIRST so any startup error - missing version.txt, broken
# bundled file, etc. - lands in the log file instead of disappearing into the
# runner's stdout void) ---
$logDir = 'C:\Logs\PreInstall'
$logFile = Join-Path $logDir 'Setup-OpenText.log'
$msiLog = Join-Path $logDir 'Setup-OpenText-msi.log'
$mspLog = Join-Path $logDir 'Setup-OpenText-msp.log'
if (-not (Test-Path $logDir)) {
New-Item -Path $logDir -ItemType Directory -Force | Out-Null
}
function Write-SetupLog {
param([string]$Message)
$line = "[$(Get-Date -Format 'yyyy-MM-dd HH:mm:ss')] $Message"
Add-Content -Path $logFile -Value $line -ErrorAction SilentlyContinue
Write-Host $line
}
Write-SetupLog "================================================================"
Write-SetupLog "=== Setup-OpenText.ps1 starting ==="
Write-SetupLog "================================================================"
Write-SetupLog "SourceDir: $SourceDir"
Write-SetupLog "PSScriptRoot: $PSScriptRoot"
Write-SetupLog "Running as: $([System.Security.Principal.WindowsIdentity]::GetCurrent().Name)"
# --- Config ---
# Version is read from version.txt next to this script. ONE source of truth: bumping
# version.txt is the only edit needed when shipping a new OpenText build. Setup-
# OpenText.ps1 itself, Install-OpenText.ps1 (DSC wrapper), and the registry marker
# all derive their notion of "expected version" from this file.
$versionFile = Join-Path $SourceDir 'version.txt'
Write-SetupLog "Looking for version.txt at: $versionFile"
if (-not (Test-Path $versionFile)) {
Write-SetupLog "ERROR: version.txt not found in $SourceDir - cannot determine expected version."
Write-SetupLog "Directory listing of $SourceDir :"
if (Test-Path $SourceDir) {
Get-ChildItem $SourceDir -ErrorAction SilentlyContinue | ForEach-Object {
Write-SetupLog " $($_.Name) $($_.Length) bytes"
}
} else {
Write-SetupLog " (SourceDir does not exist)"
}
exit 1
}
$expectedVersion = (Get-Content -Path $versionFile -Raw -ErrorAction Stop).Trim()
if (-not $expectedVersion) {
Write-SetupLog "ERROR: version.txt at $versionFile is empty."
exit 1
}
Write-SetupLog "Expected version (from version.txt): $expectedVersion"
# --- Detection: skip if already deployed at expected version ---
$markerKey = 'HKLM:\SOFTWARE\GE\OpenText'
$markerVal = 'Installed'
if (Test-Path $markerKey) {
$installed = (Get-ItemProperty -Path $markerKey -Name $markerVal -ErrorAction SilentlyContinue).$markerVal
if ($installed -eq $expectedVersion) {
Write-SetupLog "OpenText $expectedVersion already deployed (marker present) - skipping."
exit 0
}
Write-SetupLog "OpenText marker mismatch (found '$installed', expected '$expectedVersion') - re-deploying."
}
else {
Write-SetupLog "OpenText marker not present - first install."
}
# --- Verify bundled files are where we expect ---
$msiPath = Join-Path $SourceDir 'OpenTextHostExplorer15x64.msi'
$cabPath = Join-Path $SourceDir 'OpenTextHostExplorer15x64.cab'
$mspPath = Join-Path $SourceDir 'OpenTextHostExplorer15x64_ServicePack1.msp'
$mstPath = Join-Path $SourceDir 'ShopFloorx64.mst'
foreach ($f in @($msiPath, $cabPath, $mspPath, $mstPath)) {
if (-not (Test-Path $f)) {
Write-SetupLog "ERROR: required file not found: $f"
exit 1
}
}
# --- Step 1: Install the base MSI with the ShopFloor transform ---
# NOTE: We deliberately do NOT pass REBOOT=ReallySuppress here even though we do
# for the VC++ MSIs. OpenText HostExplorer installs shell extensions that hook
# explorer.exe, and the MSI uses Restart Manager to ask explorer to close so the
# in-use shell DLLs can be replaced. With REBOOT=ReallySuppress, RM closes
# explorer.exe but interprets "restart explorer" as a reboot action and refuses
# to relaunch it - leaving the user without a desktop. /norestart on its own
# prevents the actual Windows reboot but lets RM cleanly close-and-relaunch
# explorer mid-install. msiexec still returns 3010 ("reboot would be needed"),
# which we treat as success below.
Write-SetupLog ""
Write-SetupLog "Step 1: Installing OpenTextHostExplorer15x64.msi with ShopFloorx64.mst..."
if (Test-Path $msiLog) { Remove-Item $msiLog -Force -ErrorAction SilentlyContinue }
$msiArgs = "/i `"$msiPath`" TRANSFORMS=`"$mstPath`" /qn /norestart /L*v `"$msiLog`""
Write-SetupLog " msiexec.exe $msiArgs"
$psi = New-Object System.Diagnostics.ProcessStartInfo
$psi.FileName = 'msiexec.exe'
$psi.Arguments = $msiArgs
$psi.UseShellExecute = $false
$psi.CreateNoWindow = $true
$proc = [System.Diagnostics.Process]::Start($psi)
$proc.WaitForExit()
$msiExit = $proc.ExitCode
Write-SetupLog " msiexec exit code: $msiExit"
if ($msiExit -ne 0 -and $msiExit -ne 3010) {
Write-SetupLog "ERROR: base MSI install failed (exit $msiExit). See $msiLog"
exit 1
}
if ($msiExit -eq 3010) {
Write-SetupLog " (3010 = reboot needed but suppressed)"
}
# --- Step 2: Apply Service Pack 1 patch ---
# Same Restart Manager rationale as Step 1 - skip REBOOT=ReallySuppress so RM
# can relaunch explorer.exe after replacing the patched shell extension DLLs.
Write-SetupLog ""
Write-SetupLog "Step 2: Applying SP1 patch..."
if (Test-Path $mspLog) { Remove-Item $mspLog -Force -ErrorAction SilentlyContinue }
$mspArgs = "/p `"$mspPath`" /qn /norestart /L*v `"$mspLog`""
Write-SetupLog " msiexec.exe $mspArgs"
$psi.Arguments = $mspArgs
$proc = [System.Diagnostics.Process]::Start($psi)
$proc.WaitForExit()
$mspExit = $proc.ExitCode
Write-SetupLog " msiexec exit code: $mspExit"
if ($mspExit -ne 0 -and $mspExit -ne 3010) {
Write-SetupLog "ERROR: SP1 patch failed (exit $mspExit). See $mspLog"
exit 1
}
# --- Step 3: Deploy profiles, keymaps, menus, accessories ---
# Source layout (bundled with this script):
# $SourceDir\Profile\*.hep
# $SourceDir\Accessories\EB\*.eb*
# $SourceDir\HostExplorer\Keymap\*.kmv
# $SourceDir\HostExplorer\Menu\*.hmv
#
# Target layouts (Hummingbird-canonical):
# %ProgramData%\Hummingbird\Connectivity\15.00\Shared\Profile\
# %ProgramData%\Hummingbird\Connectivity\15.00\Shared\Accessories\EB\
# %ProgramData%\Hummingbird\Connectivity\15.00\Shared\HostExplorer\Keymap\
# %ProgramData%\Hummingbird\Connectivity\15.00\Shared\HostExplorer\Menu\
# <user>\AppData\Roaming\Hummingbird\Connectivity\15.00\Profile\
# <user>\AppData\Roaming\Hummingbird\Connectivity\15.00\Accessories\EB\
# <user>\AppData\Roaming\Hummingbird\Connectivity\15.00\HostExplorer\Keymap\
# <user>\AppData\Roaming\Hummingbird\Connectivity\15.00\HostExplorer\Menu\
#
# We deploy to ProgramData\Shared (system-wide fallback), Default User (template
# inherited by every NEW user profile), and every existing user profile (so
# already-created accounts like SupportUser get them immediately).
Write-SetupLog ""
Write-SetupLog "Step 3: Deploying profiles/keymaps/menus/macros..."
# --- Resolve exclude lists from site-config.json (falls back to West Jefferson defaults) ---
$siteConfig = Get-SiteConfig
$profileExcludes = if ($siteConfig -and $siteConfig.opentext -and $siteConfig.opentext.excludeProfiles) {
@($siteConfig.opentext.excludeProfiles)
} else {
@('WJ_Office.hep', 'IBM_qks.hep', 'mmcs.hep') # West Jefferson defaults
}
$shortcutExcludes = if ($siteConfig -and $siteConfig.opentext -and $siteConfig.opentext.excludeShortcuts) {
@($siteConfig.opentext.excludeShortcuts)
} else {
@('WJ_Office.lnk', 'IBM_qks.lnk', 'mmcs.lnk')
}
if ($siteConfig) {
Write-SetupLog "Site config loaded - profile excludes: $($profileExcludes -join ', ')"
Write-SetupLog "Site config loaded - shortcut excludes: $($shortcutExcludes -join ', ')"
} else {
Write-SetupLog "No site-config.json found - using West Jefferson defaults for excludes"
}
# Map of source subdir -> destination subdir relative to the Hummingbird root.
# Optional Exclude list drops specific filenames from both the source-to-dest
# copy AND from the destination if they were left over from a prior install.
$contentMap = @(
@{
Src = 'Profile'
Dst = 'Profile'
Exclude = $profileExcludes
}
@{ Src = 'Accessories\EB'; Dst = 'Accessories\EB' }
@{ Src = 'HostExplorer\Keymap'; Dst = 'HostExplorer\Keymap' }
@{ Src = 'HostExplorer\Menu'; Dst = 'HostExplorer\Menu' }
)
function Copy-HummingbirdContent {
param(
[string]$RootDst, # Hummingbird root, e.g. C:\ProgramData\Hummingbird\Connectivity\15.00\Shared
[string]$Label
)
foreach ($entry in $contentMap) {
$srcPath = Join-Path $SourceDir $entry.Src
if (-not (Test-Path $srcPath)) { continue }
$dstPath = Join-Path $RootDst $entry.Dst
New-Item -Path $dstPath -ItemType Directory -Force | Out-Null
# Remove any previously-deployed excluded files from the destination
# - handles the case where a PC got them from an older install.
if ($entry.Exclude) {
foreach ($name in $entry.Exclude) {
$stale = Join-Path $dstPath $name
if (Test-Path -LiteralPath $stale) {
try {
Remove-Item -LiteralPath $stale -Force -ErrorAction Stop
Write-SetupLog " $Label : removed stale $name"
} catch {
Write-SetupLog " $Label : failed to remove $stale : $_"
}
}
}
}
$files = Get-ChildItem -Path $srcPath -File -ErrorAction SilentlyContinue
if ($entry.Exclude) {
$files = @($files | Where-Object { $entry.Exclude -notcontains $_.Name })
}
foreach ($f in $files) {
Copy-Item -Path $f.FullName -Destination $dstPath -Force
}
Write-SetupLog " $Label : $($entry.Src) -> $dstPath ($($files.Count) files)"
}
}
# 3a. ProgramData Shared
$sharedRoot = Join-Path $env:ProgramData 'Hummingbird\Connectivity\15.00\Shared'
Copy-HummingbirdContent -RootDst $sharedRoot -Label 'Shared'
# 3b. Default User (template for new user profiles)
$defaultUserRoot = 'C:\Users\Default\AppData\Roaming\Hummingbird\Connectivity\15.00'
Copy-HummingbirdContent -RootDst $defaultUserRoot -Label 'Default User'
# 3c. Every existing user profile under C:\Users\
$skipNames = @('Default', 'Default User', 'Public', 'defaultuser0', 'All Users', 'WDAGUtilityAccount')
$userDirs = Get-ChildItem 'C:\Users' -Directory -ErrorAction SilentlyContinue |
Where-Object { $skipNames -notcontains $_.Name -and (Test-Path "$($_.FullName)\AppData\Roaming") }
foreach ($u in $userDirs) {
$userRoot = Join-Path $u.FullName 'AppData\Roaming\Hummingbird\Connectivity\15.00'
Copy-HummingbirdContent -RootDst $userRoot -Label $u.Name
}
# --- Step 4: Public Desktop shortcuts ---
# Uses $shortcutExcludes (resolved from site-config.json above) to skip
# deploying unwanted .lnk files AND remove any a prior install left behind.
Write-SetupLog ""
Write-SetupLog "Step 4: Deploying public desktop shortcuts..."
$shortcutSrc = Join-Path $SourceDir 'W10shortcuts'
$publicDesktop = 'C:\Users\Public\Desktop'
# Clean up stale copies from prior installs first
foreach ($name in $shortcutExcludes) {
$stale = Join-Path $publicDesktop $name
if (Test-Path -LiteralPath $stale) {
try {
Remove-Item -LiteralPath $stale -Force -ErrorAction Stop
Write-SetupLog " removed stale desktop shortcut: $name"
} catch {
Write-SetupLog " failed to remove stale $stale : $_"
}
}
}
if (Test-Path $shortcutSrc) {
$lnkFiles = Get-ChildItem -Path $shortcutSrc -Filter '*.lnk' -File -ErrorAction SilentlyContinue
foreach ($l in $lnkFiles) {
if ($shortcutExcludes -contains $l.Name) {
Write-SetupLog " skip (excluded): $($l.Name)"
continue
}
Copy-Item -Path $l.FullName -Destination $publicDesktop -Force
Write-SetupLog " $($l.Name) -> $publicDesktop"
}
}
# --- Step 5: Write registry marker ---
Write-SetupLog ""
Write-SetupLog "Step 5: Writing registry marker..."
if (-not (Test-Path $markerKey)) {
New-Item -Path $markerKey -Force | Out-Null
}
Set-ItemProperty -Path $markerKey -Name $markerVal -Value $expectedVersion -Force
Set-ItemProperty -Path $markerKey -Name 'InstalledAt' -Value (Get-Date -Format 'o') -Force
Write-SetupLog ""
Write-SetupLog "================================================================"
Write-SetupLog "=== OpenText HostExplorer ShopFloor $expectedVersion deployed ==="
Write-SetupLog "================================================================"
exit 0

View File

@@ -1 +0,0 @@
15.0.SP1.2

View File

@@ -1,113 +0,0 @@
@echo off
REM Install-Oracle11r2.cmd
REM Expands the GE Oracle Client 11.2 Administrator zip to a temp dir and
REM runs Oracle Universal Installer silently with the GE-customized
REM response file.
REM
REM Accepted zip locations (first hit wins):
REM %~dp0Oracle_OracleDatabase_11r2_V03.zip (preinstall flat)
REM %~dp0..\apps\Oracle_OracleDatabase_11r2_V03.zip (SFLD share, enforcer)
REM
REM Called by:
REM - preinstall runner (Type=EXE, image build time)
REM - Install-FromManifest.ps1 (Type=CMD, runtime enforcer)
REM
REM Oracle 11.2 OUI exit codes worth knowing:
REM 0 = success
REM 3 = success but with warnings
REM 1 = general failure
REM 6 = silent install requested but missing / bad response file
setlocal enabledelayedexpansion
set "LOG=C:\Logs\OracleClient\install.log"
if not exist "C:\Logs\OracleClient" mkdir "C:\Logs\OracleClient"
REM Emit a datestamp
for /f "tokens=2 delims==" %%I in ('wmic os get localdatetime /value 2^>nul ^| find "="') do set LDT=%%I
set "STAMP=!LDT:~0,14!"
echo [%STAMP%] Install-Oracle11r2.cmd starting >> "%LOG%"
set "SRC_ZIP=%~dp0Oracle_OracleDatabase_11r2_V03.zip"
if not exist "%SRC_ZIP%" set "SRC_ZIP=%~dp0..\apps\Oracle_OracleDatabase_11r2_V03.zip"
set "STAGING=%TEMP%\oracle-11r2-install"
set "CLIENT_DIR=%STAGING%\Oracle_OracleDatabase_11r2_V03\client"
set "RSP=%CLIENT_DIR%\response\ge_client_install.rsp"
if not exist "%SRC_ZIP%" (
echo [%STAMP%] ERROR: zip not found at %SRC_ZIP% >> "%LOG%"
echo ERROR: zip not found at %SRC_ZIP%
exit /b 2
)
echo [%STAMP%] Expanding %SRC_ZIP% to %STAGING% >> "%LOG%"
if exist "%STAGING%" rmdir /s /q "%STAGING%" >nul 2>&1
mkdir "%STAGING%"
powershell.exe -NoProfile -ExecutionPolicy Bypass -Command ^
"try { Expand-Archive -Path '%SRC_ZIP%' -DestinationPath '%STAGING%' -Force -ErrorAction Stop; exit 0 } catch { Write-Error $_; exit 1 }" ^
>> "%LOG%" 2>&1
if not exist "%CLIENT_DIR%\setup.exe" (
echo [%STAMP%] ERROR: expanded setup.exe not found at %CLIENT_DIR%\setup.exe >> "%LOG%"
exit /b 3
)
if not exist "%RSP%" (
echo [%STAMP%] ERROR: response file missing at %RSP% >> "%LOG%"
exit /b 4
)
echo [%STAMP%] Running OUI silent install (this takes 2-8 minutes) >> "%LOG%"
"%CLIENT_DIR%\setup.exe" -silent -waitforcompletion -nowait ^
-ignoreSysPrereqs ^
-responseFile "%RSP%" >> "%LOG%" 2>&1
set RC=%ERRORLEVEL%
echo [%STAMP%] OUI exit code: %RC% >> "%LOG%"
REM --- Drop GE-customized tnsnames.ora / sqlnet.ora / ldap.ora into ORACLE_HOME.
REM The zip ships these in client\ora\ but Oracle's setup.exe does not consume
REM them - that copy is the GE Wise wrapper's job, which we bypass. Without
REM these, every Oracle-dependent app (eDNC/UDC/NTLARS/CMM tooling) fails with
REM ORA-12154 "TNS could not resolve the connect identifier specified".
REM
REM Per-file override: if %~dp0<name>.ora exists (deployed alongside this
REM wrapper on the PXE server / SFLD share), use it instead of the bundled
REM copy. Lets us push an updated tnsnames.ora without repackaging the zip.
REM
REM Only run when OUI succeeded (RC 0 or 3). On failure ORACLE_HOME may not
REM be fully populated and the copy targets may not exist.
if %RC%==0 goto :do_ora_copy
if %RC%==3 goto :do_ora_copy
goto :skip_ora_copy
:do_ora_copy
set "ORA_DST=C:\Apps\product\11.2.0\client_1\network\admin"
if not exist "%ORA_DST%" (
echo [%STAMP%] WARN: %ORA_DST% does not exist after OUI - skipping .ora copy >> "%LOG%"
goto :skip_ora_copy
)
for %%F in (tnsnames.ora sqlnet.ora ldap.ora) do (
set "ORA_SRC=%~dp0%%F"
if not exist "!ORA_SRC!" set "ORA_SRC=%CLIENT_DIR%\ora\%%F"
if exist "!ORA_SRC!" (
echo [%STAMP%] Copying %%F from !ORA_SRC! to %ORA_DST%\%%F >> "%LOG%"
copy /Y "!ORA_SRC!" "%ORA_DST%\%%F" >> "%LOG%" 2>&1
) else (
echo [%STAMP%] WARN: %%F not found in either %~dp0 or %CLIENT_DIR%\ora >> "%LOG%"
)
)
:skip_ora_copy
REM Cleanup staging dir to reclaim ~1.5 GB - OUI copies everything to ORACLE_HOME
echo [%STAMP%] Cleaning up staging dir >> "%LOG%"
rmdir /s /q "%STAGING%" >nul 2>&1
REM OUI returns 0 for success, 3 for success-with-warnings. Treat both as OK.
if %RC%==3 (
echo [%STAMP%] OUI reported warnings but install succeeded - returning 0 >> "%LOG%"
exit /b 0
)
exit /b %RC%

File diff suppressed because it is too large Load Diff

View File

@@ -0,0 +1,13 @@
{
"Version": "1.0",
"_comment": "Site app list, installed after the post-PPKG reboot (once, as SYSTEM). Empty by default. Add one object per app to Applications and put its installer under pre-install/installers/<folder>/ on the PXE server (enrollment share). See docs/kb/How_To_Deploy_PXE_Server_New_Site.html, 'Adding shopfloor apps'.",
"_example": {
"Name": "Example App 1.2",
"Installer": "exampleapp\\ExampleApp.msi",
"Type": "MSI",
"InstallArgs": "/qn /norestart",
"DetectionMethod": "Registry",
"DetectionPath": "HKLM:\\SOFTWARE\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\{00000000-0000-0000-0000-000000000000}"
},
"Applications": []
}

View File

@@ -1,245 +1,13 @@
{
"Version": "1.0",
"Site": "West Jefferson",
"Applications": [
{
"_comment": "PowerShell 7.5.4 - installed BEFORE PPKG via FlatUnattendW10-shopfloor.xml FirstLogonCommand Order 6 (race fix: Intune SetupCredentials Win32App install command starts with pwsh.exe; if PS7 not yet installed when that Win32App fires, it errors with FILE_NOT_FOUND 0x80070002 and IME's GRS retry never re-fires under V3Processor). This entry is a backstop - no-op via ProductCode detection if unattend Order 6 already installed it. PreEnrollment flag is informational; runner does not currently filter on it.",
"Name": "PowerShell 7.5.4",
"Installer": "powershell7\\PowerShell-7.5.4-win-x64.msi",
"Type": "MSI",
"InstallArgs": "/qn /norestart ADD_PATH=1 USE_MU=0 ENABLE_MU=0 DISABLE_TELEMETRY=1",
"DetectionMethod": "Registry",
"DetectionPath": "HKLM:\\SOFTWARE\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\{E8159677-ACF8-4D64-9D36-5C36B8BBEA39}",
"PreEnrollment": true,
"PCTypes": ["*"]
},
{
"_comment": "Oracle Client 11.2 Administrator - installed first because downstream apps (eDNC/NTLARS/UDC and CMM tooling) link against the Oracle home and fail cold if it's missing. Installer is a .cmd wrapper (Type=EXE is the preinstall runner's shim for non-MSI launchers, same pattern as OpenText Setup-OpenText.cmd). The wrapper expects Oracle_OracleDatabase_11r2_V03.zip (686 MB) staged next to it, unpacks to %TEMP%, runs Oracle Universal Installer silently with ge_client_install.rsp, then cleans up the staging dir. OUI exit 3 is treated as success (warnings-but-ok). Detection via the registered home key; downstream upgrades or version pins are handled by the runtime enforcer's Oracle Client 11.2 manifest entry in common/manifest.json. Scoped to the DNC-bearing PC types (collections, nocollections, partmarker, heattreat) plus CMM, whose metrology tooling links the Oracle home; non-DNC types (Genspect, Keyence, WaxAndTrace, Display, Timeclock, Lab) do not get it.",
"Name": "Oracle Client 11.2",
"Installer": "oracle\\Install-Oracle11r2.cmd",
"Type": "EXE",
"InstallArgs": "",
"LogFile": "C:\\Logs\\OracleClient\\install.log",
"DetectionMethod": "Registry",
"DetectionPath": "HKLM:\\SOFTWARE\\WOW6432Node\\Oracle\\KEY_OraClient11g_home1",
"DetectionName": "ORACLE_HOME_NAME",
"DetectionValue": "OraClient11g_home1",
"PCTypes": ["gea-shopfloor-collections", "gea-shopfloor-nocollections", "gea-shopfloor-partmarker", "gea-shopfloor-heattreat", "gea-shopfloor-cmm"]
},
{
"_comment": "VC++ 2008 SP1 x86 - the bootstrapper (vcredist2008_x86.exe) ignores /norestart and triggers an immediate Windows reboot when files are in use (per Aaron Stebner's MSDN docs). Fix: install the extracted vc_red.msi directly with REBOOT=ReallySuppress, which IS hard-honored by Windows Installer. msiexec may return 3010 (would-have-rebooted-but-suppressed) but won't actually reboot. cab name 'vc_red.cab' is hardcoded in the MSI's Media table - do not rename.",
"Name": "VC++ Redistributable 2008 x86",
"Installer": "vcredist/2008/installer.msi",
"Type": "MSI",
"InstallArgs": "/qn /norestart REBOOT=ReallySuppress NOVSUI=1 USING_EXUIH_SILENT=1",
"DetectionMethod": "Registry",
"DetectionPath": "HKLM:\\SOFTWARE\\WOW6432Node\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\{9BE518E6-ECC6-35A9-88E4-87755C07200F}",
"PCTypes": ["gea-shopfloor-collections", "gea-shopfloor-nocollections", "gea-shopfloor-common", "gea-shopfloor-cmm", "gea-shopfloor-genspect", "gea-shopfloor-heattreat", "gea-shopfloor-keyence", "gea-shopfloor-partmarker", "gea-shopfloor-waxtrace"]
},
{
"_comment": "VC++ 2010 x86 - same fix as 2008. Bootstrapper ignores /norestart; extracted MSI with REBOOT=ReallySuppress does not.",
"Name": "VC++ Redistributable 2010 x86",
"Installer": "vcredist/2010/installer.msi",
"Type": "MSI",
"InstallArgs": "/qn /norestart REBOOT=ReallySuppress NOVSUI=1 USING_EXUIH_SILENT=1",
"DetectionMethod": "Registry",
"DetectionPath": "HKLM:\\SOFTWARE\\WOW6432Node\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\{F0C3E5D1-1ADE-321E-8167-68EF0DE699A5}",
"PCTypes": ["gea-shopfloor-collections", "gea-shopfloor-nocollections", "gea-shopfloor-common", "gea-shopfloor-cmm", "gea-shopfloor-genspect", "gea-shopfloor-heattreat", "gea-shopfloor-keyence", "gea-shopfloor-partmarker", "gea-shopfloor-waxtrace"]
},
{
"_comment": "VC++ 2012 x86 Minimum Runtime - extracted from vcredist2012_x86.exe Burn bundle. Same REBOOT=ReallySuppress fix.",
"Name": "VC++ Redistributable 2012 x86 (Minimum)",
"Installer": "vcredist/2012-min/installer.msi",
"Type": "MSI",
"InstallArgs": "/qn /norestart REBOOT=ReallySuppress NOVSUI=1 USING_EXUIH_SILENT=1",
"DetectionMethod": "Registry",
"DetectionPath": "HKLM:\\SOFTWARE\\WOW6432Node\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\{BD95A8CD-1D9F-35AD-981A-3E7925026EBB}",
"PCTypes": ["gea-shopfloor-collections", "gea-shopfloor-nocollections", "gea-shopfloor-common", "gea-shopfloor-cmm", "gea-shopfloor-genspect", "gea-shopfloor-heattreat", "gea-shopfloor-keyence", "gea-shopfloor-partmarker", "gea-shopfloor-waxtrace"]
},
{
"Name": "VC++ Redistributable 2012 x86 (Additional)",
"Installer": "vcredist/2012-add/installer.msi",
"Type": "MSI",
"InstallArgs": "/qn /norestart REBOOT=ReallySuppress NOVSUI=1 USING_EXUIH_SILENT=1",
"DetectionMethod": "Registry",
"DetectionPath": "HKLM:\\SOFTWARE\\WOW6432Node\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\{B175520C-86A2-35A7-8619-86DC379688B9}",
"PCTypes": ["gea-shopfloor-collections", "gea-shopfloor-nocollections", "gea-shopfloor-common", "gea-shopfloor-cmm", "gea-shopfloor-genspect", "gea-shopfloor-heattreat", "gea-shopfloor-keyence", "gea-shopfloor-partmarker", "gea-shopfloor-waxtrace"]
},
{
"_comment": "VC++ 2013 x86 Minimum Runtime - extracted from vcredist2013_x86.exe Burn bundle.",
"Name": "VC++ Redistributable 2013 x86 (Minimum)",
"Installer": "vcredist/2013-min/installer.msi",
"Type": "MSI",
"InstallArgs": "/qn /norestart REBOOT=ReallySuppress NOVSUI=1 USING_EXUIH_SILENT=1",
"DetectionMethod": "Registry",
"DetectionPath": "HKLM:\\SOFTWARE\\WOW6432Node\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\{13A4EE12-23EA-3371-91EE-EFB36DDFFF3E}",
"PCTypes": ["gea-shopfloor-collections", "gea-shopfloor-nocollections", "gea-shopfloor-common", "gea-shopfloor-cmm", "gea-shopfloor-genspect", "gea-shopfloor-heattreat", "gea-shopfloor-keyence", "gea-shopfloor-partmarker", "gea-shopfloor-waxtrace"]
},
{
"Name": "VC++ Redistributable 2013 x86 (Additional)",
"Installer": "vcredist/2013-add/installer.msi",
"Type": "MSI",
"InstallArgs": "/qn /norestart REBOOT=ReallySuppress NOVSUI=1 USING_EXUIH_SILENT=1",
"DetectionMethod": "Registry",
"DetectionPath": "HKLM:\\SOFTWARE\\WOW6432Node\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\{F8CFEB22-A2E7-3971-9EDA-4B11EDEFC185}",
"PCTypes": ["gea-shopfloor-collections", "gea-shopfloor-nocollections", "gea-shopfloor-common", "gea-shopfloor-cmm", "gea-shopfloor-genspect", "gea-shopfloor-heattreat", "gea-shopfloor-keyence", "gea-shopfloor-partmarker", "gea-shopfloor-waxtrace"]
},
{
"_comment": "VC++ 2013 x64 Minimum Runtime - required by Keyence VR-6000 Series Software. Extracted from the Keyence installer's Windows Installer cache. Same REBOOT=ReallySuppress pattern as the x86 variants.",
"Name": "VC++ Redistributable 2013 x64 (Minimum)",
"Installer": "vcredist/2013-x64-min/installer.msi",
"Type": "MSI",
"InstallArgs": "/qn /norestart REBOOT=ReallySuppress NOVSUI=1 USING_EXUIH_SILENT=1",
"DetectionMethod": "Registry",
"DetectionPath": "HKLM:\\SOFTWARE\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\{A749D8E6-B613-3BE3-8F5F-045C84EBA29B}",
"PCTypes": ["gea-shopfloor-collections", "gea-shopfloor-nocollections", "gea-shopfloor-common", "gea-shopfloor-cmm", "gea-shopfloor-genspect", "gea-shopfloor-heattreat", "gea-shopfloor-keyence", "gea-shopfloor-partmarker", "gea-shopfloor-waxtrace"]
},
{
"_comment": "VC++ 2013 x64 Additional Runtime - required by Keyence VR-6000 Series Software. Pairs with the Minimum Runtime above.",
"Name": "VC++ Redistributable 2013 x64 (Additional)",
"Installer": "vcredist/2013-x64-add/installer.msi",
"Type": "MSI",
"InstallArgs": "/qn /norestart REBOOT=ReallySuppress NOVSUI=1 USING_EXUIH_SILENT=1",
"DetectionMethod": "Registry",
"DetectionPath": "HKLM:\\SOFTWARE\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\{929FBD26-9020-399B-9A7A-751D61F0B942}",
"PCTypes": ["gea-shopfloor-collections", "gea-shopfloor-nocollections", "gea-shopfloor-common", "gea-shopfloor-cmm", "gea-shopfloor-genspect", "gea-shopfloor-heattreat", "gea-shopfloor-keyence", "gea-shopfloor-partmarker", "gea-shopfloor-waxtrace"]
},
{
"_comment": "VC++ 2010 x64 - required by PC-DMIS 2016/2019 R2 on CMM PCs. PCDLRN.exe links against msvcr100.dll and the VS 2010 MFC DLLs which are only provided by this redistributable. Extracted from the PC-DMIS 2016 bundle's attached container (a1 payload). Silent install: /q /norestart. Detection: Uninstall key under the native x64 hive with fixed product GUID.",
"Name": "VC++ Redistributable 2010 x64",
"Installer": "vcredist/2010-x64/vcredist_x64.exe",
"Type": "EXE",
"InstallArgs": "/q /norestart",
"DetectionMethod": "Registry",
"DetectionPath": "HKLM:\\SOFTWARE\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\{1D8E6291-B0D5-35EC-8441-6616F567A0F7}",
"DetectionName": "DisplayVersion",
"DetectionValue": "10.0.40219",
"PCTypes": ["gea-shopfloor-collections", "gea-shopfloor-nocollections", "gea-shopfloor-common", "gea-shopfloor-cmm", "gea-shopfloor-genspect", "gea-shopfloor-heattreat", "gea-shopfloor-keyence", "gea-shopfloor-partmarker", "gea-shopfloor-waxtrace"]
},
{
"_comment": "VC++ 2012 x64 - required by PC-DMIS 2016/2019 R2. Same rationale as 2010 x64; PC-DMIS links against msvcr110.dll / MFC110. Extracted from the PC-DMIS 2016 bundle's attached container (a2 payload). Detection on the Minimum Runtime GUID (the main redist wrapper installs both Minimum and Additional sub-packages).",
"Name": "VC++ Redistributable 2012 x64",
"Installer": "vcredist/2012-x64/vcredist_x64.exe",
"Type": "EXE",
"InstallArgs": "/q /norestart",
"DetectionMethod": "Registry",
"DetectionPath": "HKLM:\\SOFTWARE\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\{5AF4E09F-5C9B-3AAF-B731-544D3DC821DD}",
"DetectionName": "DisplayVersion",
"DetectionValue": "11.0.51106",
"PCTypes": ["gea-shopfloor-collections", "gea-shopfloor-nocollections", "gea-shopfloor-common", "gea-shopfloor-cmm", "gea-shopfloor-genspect", "gea-shopfloor-heattreat", "gea-shopfloor-keyence", "gea-shopfloor-partmarker", "gea-shopfloor-waxtrace"]
},
{
"_comment": "VC++ 2015-2022 x86 - extracted from vcredist2015_2017_2019_2022_x86.exe Burn bundle. The bundle contains 2022 14.44.35211 plus 8 chained KB updates for older 2015/2017/2019 releases. We install only the 2022 Min+Add MSIs - the CRT v140 ABI is shared across 2015/2017/2019/2022, so the latest pair covers all four versions on Windows 10/11.",
"Name": "VC++ Redistributable 2022 x86 (Minimum)",
"Installer": "vcredist/2022-min/installer.msi",
"Type": "MSI",
"InstallArgs": "/qn /norestart REBOOT=ReallySuppress NOVSUI=1 USING_EXUIH_SILENT=1",
"DetectionMethod": "Registry",
"DetectionPath": "HKLM:\\SOFTWARE\\WOW6432Node\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\{922480B5-CAEB-4B1B-AAA4-9716EFDCE26B}",
"PCTypes": ["gea-shopfloor-collections", "gea-shopfloor-nocollections", "gea-shopfloor-common", "gea-shopfloor-cmm", "gea-shopfloor-genspect", "gea-shopfloor-heattreat", "gea-shopfloor-keyence", "gea-shopfloor-partmarker", "gea-shopfloor-waxtrace"]
},
{
"Name": "VC++ Redistributable 2022 x86 (Additional)",
"Installer": "vcredist/2022-add/installer.msi",
"Type": "MSI",
"InstallArgs": "/qn /norestart REBOOT=ReallySuppress NOVSUI=1 USING_EXUIH_SILENT=1",
"DetectionMethod": "Registry",
"DetectionPath": "HKLM:\\SOFTWARE\\WOW6432Node\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\{C18FB403-1E88-43C8-AD8A-CED50F23DE8B}",
"PCTypes": ["gea-shopfloor-collections", "gea-shopfloor-nocollections", "gea-shopfloor-common", "gea-shopfloor-cmm", "gea-shopfloor-genspect", "gea-shopfloor-heattreat", "gea-shopfloor-keyence", "gea-shopfloor-partmarker", "gea-shopfloor-waxtrace"]
},
{
"_comment": "VC++ 2015-2022 x64 - required by PC-DMIS 2026 (PCDLRN.exe links vcruntime140_1.dll, added in VC++ 2019 / v14.20). The x64 redist line above previously stopped at 2013, so 64-bit PC-DMIS 2026 was missing its runtime and PCDLRN.exe failed to start with 'vcruntime140_1.dll was not found'. The patched PC-DMIS MSI bypasses Hexagon's Burn bundle, which is what would otherwise have pulled this in. Full vc_redist.x64.exe (14.44.35211, 2015-2022 shared CRT). Modern bootstrapper honors /norestart. Detect on the DLL itself so it is version-independent.",
"Name": "VC++ Redistributable 2015-2022 x64",
"Installer": "vcredist/2022-x64/vc_redist.x64.exe",
"Type": "EXE",
"InstallArgs": "/install /quiet /norestart",
"DetectionMethod": "File",
"DetectionPath": "C:\\Windows\\System32\\vcruntime140_1.dll",
"PCTypes": ["*"]
},
{
"_comment": "Adobe Acrobat Reader DC - same version as GEA-Engineering image. Two-step install via Install-AcroReader.cmd wrapper: base MSI with enterprise transform (AcroRead.mst) then DC update patch (AcroRdrDCUpd2500120531.msp). Source files on PXE server at /srv/samba/winpeapps/gea-engineer/Deploy/Applications/extra/adobe/ - copy to /srv/samba/enrollment/preinstall/installers/adobe/.",
"Name": "Adobe Acrobat Reader DC",
"Installer": "adobe\\Install-AcroReader.cmd",
"Type": "EXE",
"InstallArgs": "",
"DetectionMethod": "File",
"DetectionPath": "C:\\Program Files (x86)\\Adobe\\Acrobat Reader DC\\Reader\\AcroRd32.exe",
"PCTypes": ["gea-shopfloor-collections", "gea-shopfloor-nocollections", "gea-shopfloor-common", "gea-shopfloor-cmm", "gea-shopfloor-genspect", "gea-shopfloor-heattreat", "gea-shopfloor-keyence", "gea-shopfloor-partmarker", "gea-shopfloor-waxtrace"]
},
{
"_comment": "OpenText HostExplorer 15 SP1 ShopFloor - replaced the WJDT-built OpenText.exe Inno wrapper with our own Setup-OpenText.ps1 that does the same install steps (msiexec base + ShopFloor.mst transform + SP1 .msp patch) PLUS fans the per-user profile/keymap/menu/macro content out to Default User and every existing user profile. The Inno wrapper deployed per-user content to {userappdata} which resolves to whichever user is running the installer (SYSTEM under DSC, single user under PreInstall) so Azure-AD users never saw the profiles. Setup-OpenText.cmd is a tiny launcher that hands off to Setup-OpenText.ps1 because the runner only handles MSI/EXE types. All bundled files live in vcredist-style subtree at dependencies/opentext/ and get xcopied through WinPE staging. NO DetectionMethod here on purpose - Setup-OpenText.ps1 owns its own version check by reading version.txt next to itself and comparing to HKLM:\\SOFTWARE\\GE\\OpenText\\Installed; the runner always invokes the wrapper (cost: ~1s of PowerShell launch when up-to-date) so the version constant lives in exactly one place: dependencies/opentext/version.txt.",
"Name": "OpenText HostExplorer ShopFloor",
"Installer": "opentext\\Setup-OpenText.cmd",
"Type": "EXE",
"InstallArgs": "",
"LogFile": "C:\\Logs\\PreInstall\\Setup-OpenText.log",
"PCTypes": ["gea-shopfloor-collections", "gea-shopfloor-nocollections", "gea-shopfloor-common", "gea-shopfloor-cmm", "gea-shopfloor-genspect", "gea-shopfloor-heattreat", "gea-shopfloor-keyence", "gea-shopfloor-partmarker", "gea-shopfloor-waxtrace"]
},
{
"_comment": "UDC_Setup.exe spawns a hidden WPF window (UDC.exe) after install and never exits, so the runner needs KillAfterDetection: true to terminate UDC_Setup.exe + UDC.exe once the registry detection passes. This is an OPT-IN flag - normal installers should NOT set it because killing msiexec mid-install leaves msiserver holding the install mutex and the next msiexec call returns 1618 (Oracle hit this exact bug).",
"Name": "UDC",
"Installer": "UDC_Setup.exe",
"Type": "EXE",
"InstallArgs": "\"West Jefferson\" -9999",
"KillAfterDetection": true,
"DetectionMethod": "Registry",
"DetectionPath": "HKLM:\\SOFTWARE\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\UDC",
"PCTypes": ["gea-shopfloor-collections"],
"PCTypesStrict": true,
"_pcTypesNote": "UDC = the C in 'collections'. nocollections does NOT collect data so MUST NOT install UDC. PCTypesStrict bypasses the alias-expansion matcher so a nocollections PC's myNames (which transitively contains gea-shopfloor-collections via the Standard group) still won't match this entry."
},
{
"_comment": "Display kiosk app (Lobby Display or Dashboard). Install-KioskApp.cmd wrapper reads C:\\Enrollment\\display-type.txt to determine which installer to run. Both GEAerospaceLobbyDisplaySetup.exe and GEAerospaceDashboardSetup.exe must be staged in the display\\ subtree alongside the wrapper. Inno Setup /VERYSILENT is idempotent so no detection needed.",
"Name": "Display Kiosk App",
"Installer": "display\\Install-KioskApp.cmd",
"Type": "EXE",
"InstallArgs": "",
"LogFile": "C:\\Logs\\PreInstall\\Dashboard-install.log",
"PCTypes": ["Display"]
},
{
"_comment": "WJF Defect Tracker - replaces old ClickOnce deployment. MSI creates desktop + Start Menu shortcuts. Enforcer on SFLD share handles version updates post-imaging. TARGETDIR explicit because VS deployment MSI defaults to random path without it.",
"Name": "WJF Defect Tracker",
"Installer": "WJF_Defect_Tracker.msi",
"Type": "MSI",
"InstallArgs": "/qn /norestart ALLUSERS=1 REBOOT=ReallySuppress TARGETDIR=\"C:\\Program Files (x86)\\WJF_Defect_Tracker\"",
"DetectionMethod": "File",
"DetectionPath": "C:\\Program Files (x86)\\WJF_Defect_Tracker\\Defect_Tracker.exe",
"PCTypes": ["gea-shopfloor-collections", "gea-shopfloor-nocollections", "gea-shopfloor-common", "gea-shopfloor-cmm", "gea-shopfloor-genspect", "gea-shopfloor-heattreat", "gea-shopfloor-keyence", "gea-shopfloor-partmarker", "gea-shopfloor-waxtrace"]
},
{
"_comment": "Shopfloor Standard serial-port drivers: StarTech PCIe serial adapter (MosChip-based) + Prolific PL2303 USB-to-serial. Install-Drivers.cmd runs pnputil /add-driver with /subdirs /install so every bundled INF under drivers/ lands in the Windows driver store and auto-binds to matching hardware present now or plugged in later. Installed on every PC type (PCTypes ['*']) because serial hardware turns up across bays; a serial driver on a PC without the hardware is harmless - it just sits in the driver store until matching hardware is plugged in.",
"Name": "Shopfloor Serial Drivers",
"Installer": "drivers\\Install-Drivers.cmd",
"Type": "EXE",
"InstallArgs": "",
"LogFile": "C:\\Logs\\PreInstall\\Install-Drivers.log",
"DetectionMethod": "File",
"DetectionPath": "C:\\ProgramData\\PXEDrivers\\drivers-installed.marker",
"PCTypes": ["gea-shopfloor-collections", "gea-shopfloor-nocollections", "gea-shopfloor-common", "gea-shopfloor-cmm", "gea-shopfloor-genspect", "gea-shopfloor-heattreat", "gea-shopfloor-keyence", "gea-shopfloor-partmarker", "gea-shopfloor-waxtrace"]
},
{
"_comment": "HP universal print driver, staged at imaging so a bay comes off the line able to build an HP queue without waiting on the SFLD share. Set-ShopdbPrinters.ps1 creates queues against drivers that are already present and SKIPS any that are not, so without this a freshly imaged bay silently gets no printers until a later enforcement cycle tops it up. NO WAVE GATE HERE, deliberately: waves exist because ~300 bays share one runtime share, whereas imaging runs a handful of bays at a time on the isolated PXE LAN that already moves multi-GB WIMs. Detection is the SPOOLER's driver key, not pnputil - pnputil only proves the package reached the driver store, and Get-PrinterDriver (what Set-ShopdbPrinters consults) reads the spooler, so a pnputil check goes green on a half-install. Payload is NOT in git: stage printer-drivers/ onto the PXE share like the other installer payloads.",
"Name": "ShopDB Printer Driver - HP Universal PS",
"Installer": "printer-drivers\\Install-ShopdbPrinterDrivers.ps1",
"Type": "PS1",
"InstallArgs": "-Only 'HP Universal Printing PS'",
"LogFile": "C:\\Logs\\PreInstall\\printer-drivers.log",
"DetectionMethod": "Registry",
"DetectionPath": "HKLM:\\SYSTEM\\CurrentControlSet\\Control\\Print\\Environments\\Windows x64\\Drivers\\Version-3\\HP Universal Printing PS",
"PCTypes": ["gea-shopfloor-collections", "gea-shopfloor-nocollections", "gea-shopfloor-common", "gea-shopfloor-cmm", "gea-shopfloor-genspect", "gea-shopfloor-heattreat", "gea-shopfloor-keyence", "gea-shopfloor-partmarker", "gea-shopfloor-waxtrace"]
},
{
"_comment": "Xerox universal print driver. Same reasoning as the HP entry above. These two universals are 100 MB combined and resolve the overwhelming majority of the fleet's printers; the four device-specific drivers (DesignJet, Zebra ZT411, Epson C3500, FARGO card printer) are another 126 MB and are deliberately NOT staged at imaging - they belong only on the bays that have that hardware, and those bays pick them up from the runtime manifest on their next enforcement cycle.",
"Name": "ShopDB Printer Driver - Xerox Global PCL6",
"Installer": "printer-drivers\\Install-ShopdbPrinterDrivers.ps1",
"Type": "PS1",
"InstallArgs": "-Only 'Xerox Global Print Driver PCL6'",
"LogFile": "C:\\Logs\\PreInstall\\printer-drivers.log",
"DetectionMethod": "Registry",
"DetectionPath": "HKLM:\\SYSTEM\\CurrentControlSet\\Control\\Print\\Environments\\Windows x64\\Drivers\\Version-3\\Xerox Global Print Driver PCL6",
"PCTypes": ["gea-shopfloor-collections", "gea-shopfloor-nocollections", "gea-shopfloor-common", "gea-shopfloor-cmm", "gea-shopfloor-genspect", "gea-shopfloor-heattreat", "gea-shopfloor-keyence", "gea-shopfloor-partmarker", "gea-shopfloor-waxtrace"]
}
]
"_comment": "Site app list, installed during setup (same logon as the PPKG, before the post-PPKG reboot). Empty by default. Add one object per app to Applications and put its installer under pre-install/installers/<folder>/ on the PXE server (enrollment share). See docs/kb/How_To_Deploy_PXE_Server_New_Site.html, 'Adding shopfloor apps'.",
"_example": {
"Name": "Example App 1.2",
"Installer": "exampleapp\\ExampleApp.msi",
"Type": "MSI",
"InstallArgs": "/qn /norestart",
"DetectionMethod": "Registry",
"DetectionPath": "HKLM:\\SOFTWARE\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\{00000000-0000-0000-0000-000000000000}"
},
"Applications": []
}