Generic build for other GE sites: no WJ data, one shopfloor type, Windows USB builder

Everything West Jefferson specific moved out to a separate repo
(pxe-site-wj): NTLARS/UDC/heat-treat backups keyed by WJ machine numbers,
CMM and Wax/Trace bay lists, WJ OpenText profiles, site-config.json, the
WJ preinstall list, and the WJ shopfloor PC types (Collections,
NoCollections, Common, Keyence, CMM, Genspect, HeatTreat, Wax/Trace,
Display, PartMarker) with GE-Enforce, machine numbers and the desktop
layout. The part-marker bench tools moved to their own repo. Dead
scripts removed: build-proxmox-iso, deploy-bios, sync_hardware_models,
mirror-from-gold, pull-bios, startnet-template.cmd.

Shopfloor is one generic type, gea-shopfloor-standard, with today's
timing:
- PPKG at first logon (unattend Order 10, unchanged).
- Install-AppList.ps1 runs C:\PreInstall\preinstall.json during setup.
- A new SYSTEM task, GE Shopfloor Post-PPKG, runs postppkg.json once
  after the post-PPKG reboot. It also clears AutoLogonCount after the
  ShopFloor handover (the Users-level monitor can be denied that HKLM
  write) and removes the Intune Sync task when done.
- Both lists ship empty. A site adds entries and installers.
- WinPE choice 3 goes straight to the PPKG menu. Staging, fetch and heal
  carry only the generic payload. The webapp's shopfloor sub-menu editor
  is gone, and the imaging tiles name the new stages.
- The playbook deploys the empty lists only if missing. It now deploys
  the PowerShell 7 MSI the shopfloor unattend installs, which it never
  did before.

Blancco site settings move into the webapp (Updates > Blancco releases):
business location, licensing Wi-Fi SSID and password. They are rendered
into the served preferences.xml and applied to every staged release, and
are seeded from site-vars (site_name, blancco_wifi_ssid,
blancco_wifi_password) only while none exist. The repo XML carries no
site values; the plaintext Wi-Fi password is gone from it.

New site_name and site_timezone settings: report and evidence-pack site
name, server clock and webapp time zone. No more West Jefferson defaults
in webapp/config.py or the dashboard title. Sync-BPRT.ps1 gets the
server address filled in at download instead of WJ's GE address.

USB on Windows:
- scripts/Build-PxeUsb.ps1 runs the same checks as build-usb.sh. It
  writes one FAT32 CIDATA partition (ISO files plus patched grub.cfg plus
  payload) with diskpart and reads every file back by SHA-256.
- Tested with Windows PowerShell 5.1 in the win11 VM, and the layout
  installs and first-boots in the pxetest VM.
- scripts/stage-usb-share.sh stages the build folder on a share.
- site-content/ is optional for both builders.

KB docs/kb/How_To_Deploy_PXE_Server_New_Site.html: new-site deployment,
Windows only, with a site-vars.yml guide.

Checks: webapp tests pass (5 suites); the unattend lint and playbook
syntax checks pass; every .ps1 parses; there are no WJ hosts, IPs, names
or PC types in playbook/, webapp/, scripts/ or autoinstall/.
This commit is contained in:
cproudlock
2026-10-16 20:37:22 -04:00
parent b11e678297
commit 04db6d6605
710 changed files with 3113 additions and 82414 deletions

View File

@@ -1,245 +1,13 @@
{
"Version": "1.0",
"Site": "West Jefferson",
"Applications": [
{
"_comment": "PowerShell 7.5.4 - installed BEFORE PPKG via FlatUnattendW10-shopfloor.xml FirstLogonCommand Order 6 (race fix: Intune SetupCredentials Win32App install command starts with pwsh.exe; if PS7 not yet installed when that Win32App fires, it errors with FILE_NOT_FOUND 0x80070002 and IME's GRS retry never re-fires under V3Processor). This entry is a backstop - no-op via ProductCode detection if unattend Order 6 already installed it. PreEnrollment flag is informational; runner does not currently filter on it.",
"Name": "PowerShell 7.5.4",
"Installer": "powershell7\\PowerShell-7.5.4-win-x64.msi",
"Type": "MSI",
"InstallArgs": "/qn /norestart ADD_PATH=1 USE_MU=0 ENABLE_MU=0 DISABLE_TELEMETRY=1",
"DetectionMethod": "Registry",
"DetectionPath": "HKLM:\\SOFTWARE\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\{E8159677-ACF8-4D64-9D36-5C36B8BBEA39}",
"PreEnrollment": true,
"PCTypes": ["*"]
},
{
"_comment": "Oracle Client 11.2 Administrator - installed first because downstream apps (eDNC/NTLARS/UDC and CMM tooling) link against the Oracle home and fail cold if it's missing. Installer is a .cmd wrapper (Type=EXE is the preinstall runner's shim for non-MSI launchers, same pattern as OpenText Setup-OpenText.cmd). The wrapper expects Oracle_OracleDatabase_11r2_V03.zip (686 MB) staged next to it, unpacks to %TEMP%, runs Oracle Universal Installer silently with ge_client_install.rsp, then cleans up the staging dir. OUI exit 3 is treated as success (warnings-but-ok). Detection via the registered home key; downstream upgrades or version pins are handled by the runtime enforcer's Oracle Client 11.2 manifest entry in common/manifest.json. Scoped to the DNC-bearing PC types (collections, nocollections, partmarker, heattreat) plus CMM, whose metrology tooling links the Oracle home; non-DNC types (Genspect, Keyence, WaxAndTrace, Display, Timeclock, Lab) do not get it.",
"Name": "Oracle Client 11.2",
"Installer": "oracle\\Install-Oracle11r2.cmd",
"Type": "EXE",
"InstallArgs": "",
"LogFile": "C:\\Logs\\OracleClient\\install.log",
"DetectionMethod": "Registry",
"DetectionPath": "HKLM:\\SOFTWARE\\WOW6432Node\\Oracle\\KEY_OraClient11g_home1",
"DetectionName": "ORACLE_HOME_NAME",
"DetectionValue": "OraClient11g_home1",
"PCTypes": ["gea-shopfloor-collections", "gea-shopfloor-nocollections", "gea-shopfloor-partmarker", "gea-shopfloor-heattreat", "gea-shopfloor-cmm"]
},
{
"_comment": "VC++ 2008 SP1 x86 - the bootstrapper (vcredist2008_x86.exe) ignores /norestart and triggers an immediate Windows reboot when files are in use (per Aaron Stebner's MSDN docs). Fix: install the extracted vc_red.msi directly with REBOOT=ReallySuppress, which IS hard-honored by Windows Installer. msiexec may return 3010 (would-have-rebooted-but-suppressed) but won't actually reboot. cab name 'vc_red.cab' is hardcoded in the MSI's Media table - do not rename.",
"Name": "VC++ Redistributable 2008 x86",
"Installer": "vcredist/2008/installer.msi",
"Type": "MSI",
"InstallArgs": "/qn /norestart REBOOT=ReallySuppress NOVSUI=1 USING_EXUIH_SILENT=1",
"DetectionMethod": "Registry",
"DetectionPath": "HKLM:\\SOFTWARE\\WOW6432Node\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\{9BE518E6-ECC6-35A9-88E4-87755C07200F}",
"PCTypes": ["gea-shopfloor-collections", "gea-shopfloor-nocollections", "gea-shopfloor-common", "gea-shopfloor-cmm", "gea-shopfloor-genspect", "gea-shopfloor-heattreat", "gea-shopfloor-keyence", "gea-shopfloor-partmarker", "gea-shopfloor-waxtrace"]
},
{
"_comment": "VC++ 2010 x86 - same fix as 2008. Bootstrapper ignores /norestart; extracted MSI with REBOOT=ReallySuppress does not.",
"Name": "VC++ Redistributable 2010 x86",
"Installer": "vcredist/2010/installer.msi",
"Type": "MSI",
"InstallArgs": "/qn /norestart REBOOT=ReallySuppress NOVSUI=1 USING_EXUIH_SILENT=1",
"DetectionMethod": "Registry",
"DetectionPath": "HKLM:\\SOFTWARE\\WOW6432Node\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\{F0C3E5D1-1ADE-321E-8167-68EF0DE699A5}",
"PCTypes": ["gea-shopfloor-collections", "gea-shopfloor-nocollections", "gea-shopfloor-common", "gea-shopfloor-cmm", "gea-shopfloor-genspect", "gea-shopfloor-heattreat", "gea-shopfloor-keyence", "gea-shopfloor-partmarker", "gea-shopfloor-waxtrace"]
},
{
"_comment": "VC++ 2012 x86 Minimum Runtime - extracted from vcredist2012_x86.exe Burn bundle. Same REBOOT=ReallySuppress fix.",
"Name": "VC++ Redistributable 2012 x86 (Minimum)",
"Installer": "vcredist/2012-min/installer.msi",
"Type": "MSI",
"InstallArgs": "/qn /norestart REBOOT=ReallySuppress NOVSUI=1 USING_EXUIH_SILENT=1",
"DetectionMethod": "Registry",
"DetectionPath": "HKLM:\\SOFTWARE\\WOW6432Node\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\{BD95A8CD-1D9F-35AD-981A-3E7925026EBB}",
"PCTypes": ["gea-shopfloor-collections", "gea-shopfloor-nocollections", "gea-shopfloor-common", "gea-shopfloor-cmm", "gea-shopfloor-genspect", "gea-shopfloor-heattreat", "gea-shopfloor-keyence", "gea-shopfloor-partmarker", "gea-shopfloor-waxtrace"]
},
{
"Name": "VC++ Redistributable 2012 x86 (Additional)",
"Installer": "vcredist/2012-add/installer.msi",
"Type": "MSI",
"InstallArgs": "/qn /norestart REBOOT=ReallySuppress NOVSUI=1 USING_EXUIH_SILENT=1",
"DetectionMethod": "Registry",
"DetectionPath": "HKLM:\\SOFTWARE\\WOW6432Node\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\{B175520C-86A2-35A7-8619-86DC379688B9}",
"PCTypes": ["gea-shopfloor-collections", "gea-shopfloor-nocollections", "gea-shopfloor-common", "gea-shopfloor-cmm", "gea-shopfloor-genspect", "gea-shopfloor-heattreat", "gea-shopfloor-keyence", "gea-shopfloor-partmarker", "gea-shopfloor-waxtrace"]
},
{
"_comment": "VC++ 2013 x86 Minimum Runtime - extracted from vcredist2013_x86.exe Burn bundle.",
"Name": "VC++ Redistributable 2013 x86 (Minimum)",
"Installer": "vcredist/2013-min/installer.msi",
"Type": "MSI",
"InstallArgs": "/qn /norestart REBOOT=ReallySuppress NOVSUI=1 USING_EXUIH_SILENT=1",
"DetectionMethod": "Registry",
"DetectionPath": "HKLM:\\SOFTWARE\\WOW6432Node\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\{13A4EE12-23EA-3371-91EE-EFB36DDFFF3E}",
"PCTypes": ["gea-shopfloor-collections", "gea-shopfloor-nocollections", "gea-shopfloor-common", "gea-shopfloor-cmm", "gea-shopfloor-genspect", "gea-shopfloor-heattreat", "gea-shopfloor-keyence", "gea-shopfloor-partmarker", "gea-shopfloor-waxtrace"]
},
{
"Name": "VC++ Redistributable 2013 x86 (Additional)",
"Installer": "vcredist/2013-add/installer.msi",
"Type": "MSI",
"InstallArgs": "/qn /norestart REBOOT=ReallySuppress NOVSUI=1 USING_EXUIH_SILENT=1",
"DetectionMethod": "Registry",
"DetectionPath": "HKLM:\\SOFTWARE\\WOW6432Node\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\{F8CFEB22-A2E7-3971-9EDA-4B11EDEFC185}",
"PCTypes": ["gea-shopfloor-collections", "gea-shopfloor-nocollections", "gea-shopfloor-common", "gea-shopfloor-cmm", "gea-shopfloor-genspect", "gea-shopfloor-heattreat", "gea-shopfloor-keyence", "gea-shopfloor-partmarker", "gea-shopfloor-waxtrace"]
},
{
"_comment": "VC++ 2013 x64 Minimum Runtime - required by Keyence VR-6000 Series Software. Extracted from the Keyence installer's Windows Installer cache. Same REBOOT=ReallySuppress pattern as the x86 variants.",
"Name": "VC++ Redistributable 2013 x64 (Minimum)",
"Installer": "vcredist/2013-x64-min/installer.msi",
"Type": "MSI",
"InstallArgs": "/qn /norestart REBOOT=ReallySuppress NOVSUI=1 USING_EXUIH_SILENT=1",
"DetectionMethod": "Registry",
"DetectionPath": "HKLM:\\SOFTWARE\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\{A749D8E6-B613-3BE3-8F5F-045C84EBA29B}",
"PCTypes": ["gea-shopfloor-collections", "gea-shopfloor-nocollections", "gea-shopfloor-common", "gea-shopfloor-cmm", "gea-shopfloor-genspect", "gea-shopfloor-heattreat", "gea-shopfloor-keyence", "gea-shopfloor-partmarker", "gea-shopfloor-waxtrace"]
},
{
"_comment": "VC++ 2013 x64 Additional Runtime - required by Keyence VR-6000 Series Software. Pairs with the Minimum Runtime above.",
"Name": "VC++ Redistributable 2013 x64 (Additional)",
"Installer": "vcredist/2013-x64-add/installer.msi",
"Type": "MSI",
"InstallArgs": "/qn /norestart REBOOT=ReallySuppress NOVSUI=1 USING_EXUIH_SILENT=1",
"DetectionMethod": "Registry",
"DetectionPath": "HKLM:\\SOFTWARE\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\{929FBD26-9020-399B-9A7A-751D61F0B942}",
"PCTypes": ["gea-shopfloor-collections", "gea-shopfloor-nocollections", "gea-shopfloor-common", "gea-shopfloor-cmm", "gea-shopfloor-genspect", "gea-shopfloor-heattreat", "gea-shopfloor-keyence", "gea-shopfloor-partmarker", "gea-shopfloor-waxtrace"]
},
{
"_comment": "VC++ 2010 x64 - required by PC-DMIS 2016/2019 R2 on CMM PCs. PCDLRN.exe links against msvcr100.dll and the VS 2010 MFC DLLs which are only provided by this redistributable. Extracted from the PC-DMIS 2016 bundle's attached container (a1 payload). Silent install: /q /norestart. Detection: Uninstall key under the native x64 hive with fixed product GUID.",
"Name": "VC++ Redistributable 2010 x64",
"Installer": "vcredist/2010-x64/vcredist_x64.exe",
"Type": "EXE",
"InstallArgs": "/q /norestart",
"DetectionMethod": "Registry",
"DetectionPath": "HKLM:\\SOFTWARE\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\{1D8E6291-B0D5-35EC-8441-6616F567A0F7}",
"DetectionName": "DisplayVersion",
"DetectionValue": "10.0.40219",
"PCTypes": ["gea-shopfloor-collections", "gea-shopfloor-nocollections", "gea-shopfloor-common", "gea-shopfloor-cmm", "gea-shopfloor-genspect", "gea-shopfloor-heattreat", "gea-shopfloor-keyence", "gea-shopfloor-partmarker", "gea-shopfloor-waxtrace"]
},
{
"_comment": "VC++ 2012 x64 - required by PC-DMIS 2016/2019 R2. Same rationale as 2010 x64; PC-DMIS links against msvcr110.dll / MFC110. Extracted from the PC-DMIS 2016 bundle's attached container (a2 payload). Detection on the Minimum Runtime GUID (the main redist wrapper installs both Minimum and Additional sub-packages).",
"Name": "VC++ Redistributable 2012 x64",
"Installer": "vcredist/2012-x64/vcredist_x64.exe",
"Type": "EXE",
"InstallArgs": "/q /norestart",
"DetectionMethod": "Registry",
"DetectionPath": "HKLM:\\SOFTWARE\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\{5AF4E09F-5C9B-3AAF-B731-544D3DC821DD}",
"DetectionName": "DisplayVersion",
"DetectionValue": "11.0.51106",
"PCTypes": ["gea-shopfloor-collections", "gea-shopfloor-nocollections", "gea-shopfloor-common", "gea-shopfloor-cmm", "gea-shopfloor-genspect", "gea-shopfloor-heattreat", "gea-shopfloor-keyence", "gea-shopfloor-partmarker", "gea-shopfloor-waxtrace"]
},
{
"_comment": "VC++ 2015-2022 x86 - extracted from vcredist2015_2017_2019_2022_x86.exe Burn bundle. The bundle contains 2022 14.44.35211 plus 8 chained KB updates for older 2015/2017/2019 releases. We install only the 2022 Min+Add MSIs - the CRT v140 ABI is shared across 2015/2017/2019/2022, so the latest pair covers all four versions on Windows 10/11.",
"Name": "VC++ Redistributable 2022 x86 (Minimum)",
"Installer": "vcredist/2022-min/installer.msi",
"Type": "MSI",
"InstallArgs": "/qn /norestart REBOOT=ReallySuppress NOVSUI=1 USING_EXUIH_SILENT=1",
"DetectionMethod": "Registry",
"DetectionPath": "HKLM:\\SOFTWARE\\WOW6432Node\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\{922480B5-CAEB-4B1B-AAA4-9716EFDCE26B}",
"PCTypes": ["gea-shopfloor-collections", "gea-shopfloor-nocollections", "gea-shopfloor-common", "gea-shopfloor-cmm", "gea-shopfloor-genspect", "gea-shopfloor-heattreat", "gea-shopfloor-keyence", "gea-shopfloor-partmarker", "gea-shopfloor-waxtrace"]
},
{
"Name": "VC++ Redistributable 2022 x86 (Additional)",
"Installer": "vcredist/2022-add/installer.msi",
"Type": "MSI",
"InstallArgs": "/qn /norestart REBOOT=ReallySuppress NOVSUI=1 USING_EXUIH_SILENT=1",
"DetectionMethod": "Registry",
"DetectionPath": "HKLM:\\SOFTWARE\\WOW6432Node\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\{C18FB403-1E88-43C8-AD8A-CED50F23DE8B}",
"PCTypes": ["gea-shopfloor-collections", "gea-shopfloor-nocollections", "gea-shopfloor-common", "gea-shopfloor-cmm", "gea-shopfloor-genspect", "gea-shopfloor-heattreat", "gea-shopfloor-keyence", "gea-shopfloor-partmarker", "gea-shopfloor-waxtrace"]
},
{
"_comment": "VC++ 2015-2022 x64 - required by PC-DMIS 2026 (PCDLRN.exe links vcruntime140_1.dll, added in VC++ 2019 / v14.20). The x64 redist line above previously stopped at 2013, so 64-bit PC-DMIS 2026 was missing its runtime and PCDLRN.exe failed to start with 'vcruntime140_1.dll was not found'. The patched PC-DMIS MSI bypasses Hexagon's Burn bundle, which is what would otherwise have pulled this in. Full vc_redist.x64.exe (14.44.35211, 2015-2022 shared CRT). Modern bootstrapper honors /norestart. Detect on the DLL itself so it is version-independent.",
"Name": "VC++ Redistributable 2015-2022 x64",
"Installer": "vcredist/2022-x64/vc_redist.x64.exe",
"Type": "EXE",
"InstallArgs": "/install /quiet /norestart",
"DetectionMethod": "File",
"DetectionPath": "C:\\Windows\\System32\\vcruntime140_1.dll",
"PCTypes": ["*"]
},
{
"_comment": "Adobe Acrobat Reader DC - same version as GEA-Engineering image. Two-step install via Install-AcroReader.cmd wrapper: base MSI with enterprise transform (AcroRead.mst) then DC update patch (AcroRdrDCUpd2500120531.msp). Source files on PXE server at /srv/samba/winpeapps/gea-engineer/Deploy/Applications/extra/adobe/ - copy to /srv/samba/enrollment/preinstall/installers/adobe/.",
"Name": "Adobe Acrobat Reader DC",
"Installer": "adobe\\Install-AcroReader.cmd",
"Type": "EXE",
"InstallArgs": "",
"DetectionMethod": "File",
"DetectionPath": "C:\\Program Files (x86)\\Adobe\\Acrobat Reader DC\\Reader\\AcroRd32.exe",
"PCTypes": ["gea-shopfloor-collections", "gea-shopfloor-nocollections", "gea-shopfloor-common", "gea-shopfloor-cmm", "gea-shopfloor-genspect", "gea-shopfloor-heattreat", "gea-shopfloor-keyence", "gea-shopfloor-partmarker", "gea-shopfloor-waxtrace"]
},
{
"_comment": "OpenText HostExplorer 15 SP1 ShopFloor - replaced the WJDT-built OpenText.exe Inno wrapper with our own Setup-OpenText.ps1 that does the same install steps (msiexec base + ShopFloor.mst transform + SP1 .msp patch) PLUS fans the per-user profile/keymap/menu/macro content out to Default User and every existing user profile. The Inno wrapper deployed per-user content to {userappdata} which resolves to whichever user is running the installer (SYSTEM under DSC, single user under PreInstall) so Azure-AD users never saw the profiles. Setup-OpenText.cmd is a tiny launcher that hands off to Setup-OpenText.ps1 because the runner only handles MSI/EXE types. All bundled files live in vcredist-style subtree at dependencies/opentext/ and get xcopied through WinPE staging. NO DetectionMethod here on purpose - Setup-OpenText.ps1 owns its own version check by reading version.txt next to itself and comparing to HKLM:\\SOFTWARE\\GE\\OpenText\\Installed; the runner always invokes the wrapper (cost: ~1s of PowerShell launch when up-to-date) so the version constant lives in exactly one place: dependencies/opentext/version.txt.",
"Name": "OpenText HostExplorer ShopFloor",
"Installer": "opentext\\Setup-OpenText.cmd",
"Type": "EXE",
"InstallArgs": "",
"LogFile": "C:\\Logs\\PreInstall\\Setup-OpenText.log",
"PCTypes": ["gea-shopfloor-collections", "gea-shopfloor-nocollections", "gea-shopfloor-common", "gea-shopfloor-cmm", "gea-shopfloor-genspect", "gea-shopfloor-heattreat", "gea-shopfloor-keyence", "gea-shopfloor-partmarker", "gea-shopfloor-waxtrace"]
},
{
"_comment": "UDC_Setup.exe spawns a hidden WPF window (UDC.exe) after install and never exits, so the runner needs KillAfterDetection: true to terminate UDC_Setup.exe + UDC.exe once the registry detection passes. This is an OPT-IN flag - normal installers should NOT set it because killing msiexec mid-install leaves msiserver holding the install mutex and the next msiexec call returns 1618 (Oracle hit this exact bug).",
"Name": "UDC",
"Installer": "UDC_Setup.exe",
"Type": "EXE",
"InstallArgs": "\"West Jefferson\" -9999",
"KillAfterDetection": true,
"DetectionMethod": "Registry",
"DetectionPath": "HKLM:\\SOFTWARE\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\UDC",
"PCTypes": ["gea-shopfloor-collections"],
"PCTypesStrict": true,
"_pcTypesNote": "UDC = the C in 'collections'. nocollections does NOT collect data so MUST NOT install UDC. PCTypesStrict bypasses the alias-expansion matcher so a nocollections PC's myNames (which transitively contains gea-shopfloor-collections via the Standard group) still won't match this entry."
},
{
"_comment": "Display kiosk app (Lobby Display or Dashboard). Install-KioskApp.cmd wrapper reads C:\\Enrollment\\display-type.txt to determine which installer to run. Both GEAerospaceLobbyDisplaySetup.exe and GEAerospaceDashboardSetup.exe must be staged in the display\\ subtree alongside the wrapper. Inno Setup /VERYSILENT is idempotent so no detection needed.",
"Name": "Display Kiosk App",
"Installer": "display\\Install-KioskApp.cmd",
"Type": "EXE",
"InstallArgs": "",
"LogFile": "C:\\Logs\\PreInstall\\Dashboard-install.log",
"PCTypes": ["Display"]
},
{
"_comment": "WJF Defect Tracker - replaces old ClickOnce deployment. MSI creates desktop + Start Menu shortcuts. Enforcer on SFLD share handles version updates post-imaging. TARGETDIR explicit because VS deployment MSI defaults to random path without it.",
"Name": "WJF Defect Tracker",
"Installer": "WJF_Defect_Tracker.msi",
"Type": "MSI",
"InstallArgs": "/qn /norestart ALLUSERS=1 REBOOT=ReallySuppress TARGETDIR=\"C:\\Program Files (x86)\\WJF_Defect_Tracker\"",
"DetectionMethod": "File",
"DetectionPath": "C:\\Program Files (x86)\\WJF_Defect_Tracker\\Defect_Tracker.exe",
"PCTypes": ["gea-shopfloor-collections", "gea-shopfloor-nocollections", "gea-shopfloor-common", "gea-shopfloor-cmm", "gea-shopfloor-genspect", "gea-shopfloor-heattreat", "gea-shopfloor-keyence", "gea-shopfloor-partmarker", "gea-shopfloor-waxtrace"]
},
{
"_comment": "Shopfloor Standard serial-port drivers: StarTech PCIe serial adapter (MosChip-based) + Prolific PL2303 USB-to-serial. Install-Drivers.cmd runs pnputil /add-driver with /subdirs /install so every bundled INF under drivers/ lands in the Windows driver store and auto-binds to matching hardware present now or plugged in later. Installed on every PC type (PCTypes ['*']) because serial hardware turns up across bays; a serial driver on a PC without the hardware is harmless - it just sits in the driver store until matching hardware is plugged in.",
"Name": "Shopfloor Serial Drivers",
"Installer": "drivers\\Install-Drivers.cmd",
"Type": "EXE",
"InstallArgs": "",
"LogFile": "C:\\Logs\\PreInstall\\Install-Drivers.log",
"DetectionMethod": "File",
"DetectionPath": "C:\\ProgramData\\PXEDrivers\\drivers-installed.marker",
"PCTypes": ["gea-shopfloor-collections", "gea-shopfloor-nocollections", "gea-shopfloor-common", "gea-shopfloor-cmm", "gea-shopfloor-genspect", "gea-shopfloor-heattreat", "gea-shopfloor-keyence", "gea-shopfloor-partmarker", "gea-shopfloor-waxtrace"]
},
{
"_comment": "HP universal print driver, staged at imaging so a bay comes off the line able to build an HP queue without waiting on the SFLD share. Set-ShopdbPrinters.ps1 creates queues against drivers that are already present and SKIPS any that are not, so without this a freshly imaged bay silently gets no printers until a later enforcement cycle tops it up. NO WAVE GATE HERE, deliberately: waves exist because ~300 bays share one runtime share, whereas imaging runs a handful of bays at a time on the isolated PXE LAN that already moves multi-GB WIMs. Detection is the SPOOLER's driver key, not pnputil - pnputil only proves the package reached the driver store, and Get-PrinterDriver (what Set-ShopdbPrinters consults) reads the spooler, so a pnputil check goes green on a half-install. Payload is NOT in git: stage printer-drivers/ onto the PXE share like the other installer payloads.",
"Name": "ShopDB Printer Driver - HP Universal PS",
"Installer": "printer-drivers\\Install-ShopdbPrinterDrivers.ps1",
"Type": "PS1",
"InstallArgs": "-Only 'HP Universal Printing PS'",
"LogFile": "C:\\Logs\\PreInstall\\printer-drivers.log",
"DetectionMethod": "Registry",
"DetectionPath": "HKLM:\\SYSTEM\\CurrentControlSet\\Control\\Print\\Environments\\Windows x64\\Drivers\\Version-3\\HP Universal Printing PS",
"PCTypes": ["gea-shopfloor-collections", "gea-shopfloor-nocollections", "gea-shopfloor-common", "gea-shopfloor-cmm", "gea-shopfloor-genspect", "gea-shopfloor-heattreat", "gea-shopfloor-keyence", "gea-shopfloor-partmarker", "gea-shopfloor-waxtrace"]
},
{
"_comment": "Xerox universal print driver. Same reasoning as the HP entry above. These two universals are 100 MB combined and resolve the overwhelming majority of the fleet's printers; the four device-specific drivers (DesignJet, Zebra ZT411, Epson C3500, FARGO card printer) are another 126 MB and are deliberately NOT staged at imaging - they belong only on the bays that have that hardware, and those bays pick them up from the runtime manifest on their next enforcement cycle.",
"Name": "ShopDB Printer Driver - Xerox Global PCL6",
"Installer": "printer-drivers\\Install-ShopdbPrinterDrivers.ps1",
"Type": "PS1",
"InstallArgs": "-Only 'Xerox Global Print Driver PCL6'",
"LogFile": "C:\\Logs\\PreInstall\\printer-drivers.log",
"DetectionMethod": "Registry",
"DetectionPath": "HKLM:\\SYSTEM\\CurrentControlSet\\Control\\Print\\Environments\\Windows x64\\Drivers\\Version-3\\Xerox Global Print Driver PCL6",
"PCTypes": ["gea-shopfloor-collections", "gea-shopfloor-nocollections", "gea-shopfloor-common", "gea-shopfloor-cmm", "gea-shopfloor-genspect", "gea-shopfloor-heattreat", "gea-shopfloor-keyence", "gea-shopfloor-partmarker", "gea-shopfloor-waxtrace"]
}
]
"_comment": "Site app list, installed during setup (same logon as the PPKG, before the post-PPKG reboot). Empty by default. Add one object per app to Applications and put its installer under pre-install/installers/<folder>/ on the PXE server (enrollment share). See docs/kb/How_To_Deploy_PXE_Server_New_Site.html, 'Adding shopfloor apps'.",
"_example": {
"Name": "Example App 1.2",
"Installer": "exampleapp\\ExampleApp.msi",
"Type": "MSI",
"InstallArgs": "/qn /norestart",
"DetectionMethod": "Registry",
"DetectionPath": "HKLM:\\SOFTWARE\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\{00000000-0000-0000-0000-000000000000}"
},
"Applications": []
}