CMM: grant Users Modify on PC-DMIS install dirs for non-admin launch
PC-DMIS writes settings, probe configs, and measurement data to its own Program Files install directory at runtime. Without Modify permission for BUILTIN\Users, non-admin accounts (ShopFloor) get a UAC elevation prompt on every launch. The "run as admin once" workaround can't be automated because PC-DMIS shows a license dialog on first run that blocks silently. Fix: grant BUILTIN\Users Modify with inheritance on: - C:\Program Files\Hexagon\PC-DMIS 2016.0 64-bit - C:\Program Files\Hexagon\PC-DMIS 2019 R2 64-bit - C:\ProgramData\Hexagon Runs as Step 2.5 in 09-Setup-CMM.ps1 after Install-FromManifest completes. If the exe also has an embedded requireAdministrator manifest (separate from the file-permission issue), that will need an additional fix after testing. Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
This commit is contained in:
@@ -124,6 +124,42 @@ else {
|
|||||||
Write-CMMLog "Install-FromManifest returned $rc"
|
Write-CMMLog "Install-FromManifest returned $rc"
|
||||||
}
|
}
|
||||||
|
|
||||||
|
# ============================================================================
|
||||||
|
# Step 2.5: Grant Users write access to PC-DMIS install directories
|
||||||
|
# ============================================================================
|
||||||
|
# PC-DMIS writes settings, probe configs, and measurement data to its own
|
||||||
|
# install directory at runtime. Without Modify permission for BUILTIN\Users,
|
||||||
|
# non-admin accounts get a UAC elevation prompt on every launch. Granting
|
||||||
|
# the ACL here is the Hexagon-documented approach for non-admin deployment
|
||||||
|
# and avoids the need for a first-run-as-admin (which hits a license dialog
|
||||||
|
# and can't be automated silently).
|
||||||
|
$pcdmisDirs = @(
|
||||||
|
'C:\Program Files\Hexagon\PC-DMIS 2016.0 64-bit',
|
||||||
|
'C:\Program Files\Hexagon\PC-DMIS 2019 R2 64-bit',
|
||||||
|
'C:\ProgramData\Hexagon'
|
||||||
|
)
|
||||||
|
foreach ($dir in $pcdmisDirs) {
|
||||||
|
if (-not (Test-Path -LiteralPath $dir)) {
|
||||||
|
Write-CMMLog "PC-DMIS dir not found: $dir - skipping ACL"
|
||||||
|
continue
|
||||||
|
}
|
||||||
|
try {
|
||||||
|
$acl = Get-Acl -LiteralPath $dir
|
||||||
|
$rule = New-Object System.Security.AccessControl.FileSystemAccessRule(
|
||||||
|
'BUILTIN\Users',
|
||||||
|
'Modify',
|
||||||
|
'ContainerInherit,ObjectInherit',
|
||||||
|
'None',
|
||||||
|
'Allow'
|
||||||
|
)
|
||||||
|
$acl.AddAccessRule($rule)
|
||||||
|
Set-Acl -LiteralPath $dir -AclObject $acl -ErrorAction Stop
|
||||||
|
Write-CMMLog "Granted BUILTIN\Users Modify on $dir"
|
||||||
|
} catch {
|
||||||
|
Write-CMMLog "Failed to set ACL on $dir : $_" "WARN"
|
||||||
|
}
|
||||||
|
}
|
||||||
|
|
||||||
# ============================================================================
|
# ============================================================================
|
||||||
# Step 3: Stage runtime scripts to C:\Program Files\GE\CMM
|
# Step 3: Stage runtime scripts to C:\Program Files\GE\CMM
|
||||||
# ============================================================================
|
# ============================================================================
|
||||||
|
|||||||
Reference in New Issue
Block a user