Monitor-IntuneProgress: auto-fire idx=8 on lockdown detection
Local-user shopfloor fleet (ShopFloor is a LOCAL account) means AzureAdPrt stays NO, user-scoped Intune policies never deliver, and the natural completion gate (baseline policies >= 5 + DSCInstall success + Phase 4 wrappers) never closes. Dashboard sessions stuck at 7/8 / 87.5% forever even though the bay is functionally complete. Real-world definition of "done" for these bays is lockdown applied. Add a per-tick check in Get-Phase1 (alongside the DeviceId push) that detects either: * Winlogon DefaultUserName -like 'ShopFloor*' AND AutoAdminLogon=1 * OR C:\Enrollment\force-lockdown-applied.txt marker file When either is present and not yet pushed, fire Send-PxeStatus StageIndex=8 / StageTotal=8 / Status='succeeded' with the captured IntuneDeviceId for the dashboard QR. One-shot per session via the LockdownCompletePushed cache flag. No need for the operator to run mark-complete.bat anymore - Monitor's main loop will fire idx=8 within ~5s of force-lockdown or autologon flip. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
This commit is contained in:
@@ -186,6 +186,7 @@ $script:cache = @{
|
|||||||
EnrollmentId = $null
|
EnrollmentId = $null
|
||||||
DeviceId = $null
|
DeviceId = $null
|
||||||
DeviceIdReported = $false
|
DeviceIdReported = $false
|
||||||
|
LockdownCompletePushed = $false
|
||||||
}
|
}
|
||||||
|
|
||||||
# Load Send-PxeStatus at SCRIPT scope (not inside a function). A dot-source
|
# Load Send-PxeStatus at SCRIPT scope (not inside a function). A dot-source
|
||||||
@@ -235,6 +236,46 @@ function Get-Phase1 {
|
|||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|
||||||
|
# Lockdown-applied auto-completion. Fleet-wide reality: bays use a LOCAL
|
||||||
|
# ShopFloor account, so AzureAdPrt stays NO and user-scoped Intune policies
|
||||||
|
# never deliver. The natural completion gate (baseline policies >= 5, DSC
|
||||||
|
# Installation completed successfully, all Phase 4 wrappers) therefore
|
||||||
|
# never closes - leaves the dashboard stuck at 7/8 = 87.5% forever.
|
||||||
|
#
|
||||||
|
# Real-world definition of "done" for these bays is lockdown applied:
|
||||||
|
# Winlogon DefaultUserName flipped to ShopFloor + AutoAdminLogon=1, OR
|
||||||
|
# the force-lockdown marker has been written by sfld_autologon.ps1.
|
||||||
|
# When either signal is present, push idx=8 / status=succeeded so the
|
||||||
|
# dashboard card flips to 100% green.
|
||||||
|
if (-not $script:cache.LockdownCompletePushed) {
|
||||||
|
$lockdownApplied = $false
|
||||||
|
try {
|
||||||
|
$wl = Get-ItemProperty 'HKLM:\SOFTWARE\Microsoft\Windows NT\CurrentVersion\Winlogon' -ErrorAction Stop
|
||||||
|
if ([string]$wl.AutoAdminLogon -eq '1' -and $wl.DefaultUserName -like 'ShopFloor*') {
|
||||||
|
$lockdownApplied = $true
|
||||||
|
}
|
||||||
|
} catch {}
|
||||||
|
if (-not $lockdownApplied -and (Test-Path 'C:\Enrollment\force-lockdown-applied.txt')) {
|
||||||
|
$lockdownApplied = $true
|
||||||
|
}
|
||||||
|
if ($lockdownApplied) {
|
||||||
|
Ensure-SendPxeStatus
|
||||||
|
if (Get-Command Send-PxeStatus -ErrorAction SilentlyContinue) {
|
||||||
|
try {
|
||||||
|
$params = @{
|
||||||
|
Stage = 'Monitor-IntuneProgress: lockdown applied (imaging complete)'
|
||||||
|
StageIndex = 8
|
||||||
|
StageTotal = 8
|
||||||
|
Status = 'succeeded'
|
||||||
|
}
|
||||||
|
if ($script:cache.DeviceId) { $params.IntuneDeviceId = $script:cache.DeviceId }
|
||||||
|
Send-PxeStatus @params
|
||||||
|
$script:cache.LockdownCompletePushed = $true
|
||||||
|
} catch { }
|
||||||
|
}
|
||||||
|
}
|
||||||
|
}
|
||||||
|
|
||||||
if (-not $script:cache.IntuneEnrolled) {
|
if (-not $script:cache.IntuneEnrolled) {
|
||||||
$eid = Get-EnrollmentId
|
$eid = Get-EnrollmentId
|
||||||
if ($eid) {
|
if ($eid) {
|
||||||
|
|||||||
Reference in New Issue