Fix Report IP glob (.LOG not .txt) + add device-id copy button

Field bay surfaced two bugs in one diag dump (mdm-diag-F907T5X3 -
6PPSF24):

1. GE Proactive Remediation Report IP actually writes
   GE_Report_IP_Address_2_5.LOG (uppercase .LOG), not the .txt I
   assumed. Globs in two places had .txt filter -> never matched ->
   Phase 1 stuck IN PROGRESS forever even after the file landed and
   wired-NIC re-enable never fired. Drop extension from both globs
   in Monitor-IntuneProgress.ps1 (id=7 push gate + p1Done check).

2. The "GE Re-enable Wired NICs" SYSTEM task registered by
   Run-ShopfloorSetup was polling Autologon_Remediation.log for
   "Autologon set for ShopFloor" - a lockdown-time signal. Re-enable
   needs to fire at Report-IP time (well before lockdown) so that
   Monitor can push idx=7 with the QR before the Intune-triggered
   LAPS-prompt reboot. Repoint the SYSTEM task's poll to
   C:\Logs\GE_Report_IP_Address* (any extension).

Plus minor UX: copy button next to the Intune device ID on
/imaging dashboard so techs can grab the GUID without having to
double-click-select the <code>.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
This commit is contained in:
cproudlock
2026-05-13 18:27:26 -04:00
parent 7e1ea03f02
commit 59dbd64e37
3 changed files with 15 additions and 8 deletions

View File

@@ -310,11 +310,14 @@ if (Test-Path -LiteralPath $monitorScript) {
$reEnableTask = 'GE Re-enable Wired NICs'
try {
$script = @'
$imeLogs = 'C:\ProgramData\Microsoft\IntuneManagementExtension\Logs'
$remLog = Join-Path $imeLogs 'Autologon_Remediation.log'
if (-not (Test-Path $remLog)) { exit 0 }
$content = Get-Content $remLog -Raw -ErrorAction SilentlyContinue
if ($content -notmatch 'Autologon set for ShopFloor') { exit 0 }
# Poll for the GE Report-IP Proactive Remediation log file. Its appearance
# means the Report IP script has fired with WiFi-only IPs (because we
# disabled wired post-PPKG) - which is the exact moment we want to bring
# wired back up so Monitor-IntuneProgress can push idx=7 with the
# DeviceId / QR code before the Intune-triggered LAPS-prompt reboot lands.
# Extension is .LOG (not .txt) observed in field; match any extension.
$ip = Get-ChildItem 'C:\Logs\GE_Report_IP_Address*' -ErrorAction SilentlyContinue | Select-Object -First 1
if (-not $ip) { exit 0 }
# Vendor-agnostic wired-NIC re-enable. NetAdapter "Name" varies wildly
# ("Ethernet", "Ethernet 2", "Network", per-vendor names like "Realtek