NICs: pick the imaging port at install, GE can go into any other port
Sites no longer need either MAC in site-vars. pxe_nic_mac empty: before anything changes, the playbook runs pxe-pick-nic --auto. It takes the one wired port with a link, accepts it only if pxe-nic-check calls it isolated (no LLDP/CDP/802.1X, no other DHCP server, at most 10 hosts heard in 65 s), and pins it. The choice is saved in /etc/pxe-server/nic-pick.conf and never re-guessed at boot. When it cannot tell (no link, two links, not isolated) nothing changes, and the console banner says why and to run sudo pxe-pick-nic: pull the imaging cable and plug it back in, and the port that blinked is the imaging one. Both helpers are installed before the pick, so that works after a refused first boot. The site's corp domains and allowed switches are passed to the check. corp_nic_mac empty: every other wired port (en*, eth*) is a catch-all DHCP client, so GE can be plugged in at install or later. - dnsmasq stays pinned with interface=pxe0. A new check refuses any dhcp-range outside the imaging subnet, and proxy ranges. - The catch-all ports ignore offers from 172.16.9.1. - UFW allows SSH and 9009 by source on any interface, and keeps those rules when the old any-interface rules are removed. - pxe_nic_name must not look like en*/eth* in this mode. pxe-netplan-apply.sh takes 3 or 5 args. Without a pinned GE NIC it: - renames stray names (the old pxe0 after a re-pick, a leftover corp0) to enx<mac>, so the catch-all takes them, and restores them on revert; - checks that every NIC that had a DHCP address before has one after, tracked by MAC. With both MACs set (the WJ server), netplan, the dnsmasq pin and UFW render byte-for-byte as before. Tested in the pxetest VMs: - Fresh install with no MACs and the GE link down: the imaging port was picked and pinned as pxe0 with 172.16.9.1, and dnsmasq bound DHCP to pxe0 only. GE plugged in afterwards got a lease, SSH worked, and the guard reported pxe0 isolated. - --auto refuses with two links. - The interactive pick works by pulling and replugging the link. - A 3-arg re-apply is UNCHANGED. Unit tests (fake sysfs) cover the re-pick and pinned-to-catch-all renames.
This commit is contained in:
@@ -14,8 +14,9 @@ autoinstall:
|
||||
# the imaging LAN) stays without one. No static 172.16.9.1 here: matched
|
||||
# by name it would land on EVERY NIC, the GE one included, and the box
|
||||
# would answer as 172.16.9.1 on the corporate network. First boot's
|
||||
# playbook replaces this file with the two-NIC config pinned by MAC
|
||||
# (pxe_nic_mac / corp_nic_mac in playbook/site-vars.yml). optional: the
|
||||
# playbook replaces this file with the imaging NIC pinned by MAC
|
||||
# (pxe_nic_mac in playbook/site-vars.yml, or picked by its link when
|
||||
# empty; corp_nic_mac optional). optional: the
|
||||
# install and boot never wait for a lease (air-gapped is fine).
|
||||
network:
|
||||
version: 2
|
||||
@@ -139,9 +140,12 @@ autoinstall:
|
||||
if mount "$CIDATA_DEV" /mnt/usb; then
|
||||
if [ -f /mnt/usb/playbook/pxe_server_setup.yml ]; then
|
||||
cd /mnt/usb/playbook
|
||||
rm -f "$STATE/nic-hint"
|
||||
ansible-playbook -i localhost, -c local pxe_server_setup.yml
|
||||
RC=$?
|
||||
WHY="ansible-playbook exit code $RC"
|
||||
# pxe-pick-nic leaves the reason it could not pick the imaging NIC
|
||||
[ "$RC" -ne 0 ] && [ -s "$STATE/nic-hint" ] && WHY="$(head -1 "$STATE/nic-hint")"
|
||||
cd /
|
||||
else
|
||||
WHY="no playbook/pxe_server_setup.yml on CIDATA"
|
||||
|
||||
Reference in New Issue