Kill wired NICs post-stage-2 until Report IP log appears
Recurring Phase 2 "Device Configuration" stuck: GE Intune Proactive Remediation "Report IP" script enumerates Get-NetIPAddress and POSTs all IPs to a GE webhook. Bays cabled to air-gapped PXE LAN have 10.9.100.x leak into that report. GE backend tags bays "not on corp net" -> dynamic-group assignment-filter at GE excludes them from the SFLD ConfigurationProfile (Function + SasToken OMA-URI) -> HKLM:\SOFTWARE\GE\SFLD\DSC never populates -> Monitor Phase 2 gate never closes. Confirmed via mdm-diag-F907T5X3 dump: every Microsoft policy delivered fine, zero SFLD/GE-namespace OMA-URI present. Fix flow: 1. Run-ShopfloorSetup line 43: disable every Up wired NIC right after stage 2 push. NIC names persisted to C:\Enrollment\disabled-wired-nics.txt for later re-enable. 2. Stages 3-6 status pushes fail silently while wired is down (PXE server lives on the air-gapped 10.9.100.0/24 LAN, unreachable from WiFi). Dashboard goes dark in that window. 3. PPKG installs, immediate reboot, AAD/Intune enroll over WiFi only. 4. IME boots, Report IP script fires with corp-WiFi IP only, writes C:\Logs\GE_Report_IP_Address*.txt. Webhook records clean IP. GE dynamic group eligibility flips. SFLD policy delivers next sync. 5. Monitor-IntuneProgress detects the log file, re-enables every NIC in the persisted list, sleeps 1s for link, then pushes idx=7 with DeviceId so the dashboard card flips to QR before the Intune- triggered LAPS-prompt reboot lands. Phase 1 remains "in progress" on the dashboard until Report IP fires - correct, the bay isn't actually registration-clean until then. Files: - Disable-WiredNics.ps1 (new) - persists names + disables - Run-ShopfloorSetup.ps1 - call after stage 2 Report-Stage - Monitor-IntuneProgress.ps1 - gate idx=7 push + re-enable Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
This commit is contained in:
45
playbook/shopfloor-setup/Shopfloor/lib/Disable-WiredNics.ps1
Normal file
45
playbook/shopfloor-setup/Shopfloor/lib/Disable-WiredNics.ps1
Normal file
@@ -0,0 +1,45 @@
|
||||
# Disable-WiredNics.ps1
|
||||
# Disables every Up wired (MediaType 802.3) NIC and records their names to
|
||||
# C:\Enrollment\disabled-wired-nics.txt so Monitor-IntuneProgress can
|
||||
# re-enable them once Report IP has run on WiFi-only.
|
||||
#
|
||||
# Reason: GE's Intune Proactive-Remediation "Report IP" script enumerates
|
||||
# Get-NetIPAddress and POSTs every IP it finds to a GE webhook. When a
|
||||
# shopfloor bay is still cabled to the air-gapped PXE LAN (10.9.100.0/24),
|
||||
# the webhook sees 10.9.100.x as one of the device's IPs and tags the bay
|
||||
# "not on corp net". A dynamic group / assignment-filter at GE then excludes
|
||||
# the bay from receiving the SFLD ConfigurationProfile (Function + SasToken
|
||||
# OMA-URI) -> Phase 2 "Device Configuration" never closes.
|
||||
#
|
||||
# Killing the wired NIC after stage 2 reports + before AAD-join makes the
|
||||
# bay's first Report IP fire see corp-WiFi IP only. The bay is tagged
|
||||
# clean, dynamic group eligibility flips, SFLD policy delivers normally.
|
||||
# Monitor-IntuneProgress re-enables the NIC once Report IP's log file
|
||||
# appears at C:\Logs\GE_Report_IP_Address*.txt.
|
||||
|
||||
$ErrorActionPreference = 'Continue'
|
||||
$stateFile = 'C:\Enrollment\disabled-wired-nics.txt'
|
||||
|
||||
try {
|
||||
$wired = Get-NetAdapter -ErrorAction Stop |
|
||||
Where-Object {
|
||||
$_.Status -eq 'Up' -and
|
||||
$_.MediaType -eq '802.3' -and
|
||||
$_.HardwareInterface -eq $true
|
||||
}
|
||||
|
||||
if (-not $wired) {
|
||||
Write-Host "Disable-WiredNics: no Up wired NICs found - nothing to disable."
|
||||
return
|
||||
}
|
||||
|
||||
$names = $wired | ForEach-Object { $_.Name }
|
||||
$names | Out-File -FilePath $stateFile -Encoding ASCII -Force
|
||||
Write-Host ("Disable-WiredNics: persisted {0} NIC name(s) -> {1}" -f $names.Count, $stateFile)
|
||||
foreach ($n in $names) { Write-Host " - $n" }
|
||||
|
||||
$wired | Disable-NetAdapter -Confirm:$false -ErrorAction Continue
|
||||
Write-Host "Disable-WiredNics: NICs disabled. Re-enable triggered by Monitor when GE_Report_IP_Address log appears."
|
||||
} catch {
|
||||
Write-Warning "Disable-WiredNics: failed: $_"
|
||||
}
|
||||
@@ -223,16 +223,47 @@ function Get-Phase1 {
|
||||
}
|
||||
|
||||
# Push DeviceId to the PXE dashboard exactly once (the imaging.html card
|
||||
# renders a QR of it). Best-effort.
|
||||
# renders a QR of it). Gated on Report IP log existing: Run-ShopfloorSetup
|
||||
# disabled wired NICs after stage 2 push so GE's Report IP webhook only
|
||||
# sees the corp-WiFi IP. We wait for the log file to appear (proof Report
|
||||
# IP fired clean), re-enable the NICs we recorded, sleep a tick so the
|
||||
# interface comes back up, then push idx=7. Until the log exists, Phase 1
|
||||
# stays "in progress" on the dashboard - which is correct, the bay is
|
||||
# not actually "done with registration" until the Report IP step has
|
||||
# cleared.
|
||||
if ($script:cache.DeviceId -and -not $script:cache.DeviceIdReported) {
|
||||
Ensure-SendPxeStatus
|
||||
if (Get-Command Send-PxeStatus -ErrorAction SilentlyContinue) {
|
||||
try {
|
||||
Send-PxeStatus -Stage 'Monitor-IntuneProgress: Intune Device ID captured' `
|
||||
-StageIndex 7 -StageTotal 8 `
|
||||
-IntuneDeviceId $script:cache.DeviceId
|
||||
$script:cache.DeviceIdReported = $true
|
||||
} catch { }
|
||||
$reportIpLog = Get-ChildItem -Path 'C:\Logs\GE_Report_IP_Address*.txt' -ErrorAction SilentlyContinue |
|
||||
Select-Object -First 1
|
||||
if ($reportIpLog) {
|
||||
# Re-enable any wired NICs Run-ShopfloorSetup disabled. Quick
|
||||
# before the eventual Intune-driven reboot fires so the bay
|
||||
# gets a clean wired path back to the PXE dashboard for idx=7
|
||||
# + idx=8 pushes.
|
||||
$nicListFile = 'C:\Enrollment\disabled-wired-nics.txt'
|
||||
if (Test-Path $nicListFile) {
|
||||
try {
|
||||
$nicNames = Get-Content $nicListFile -ErrorAction Stop
|
||||
foreach ($n in $nicNames) {
|
||||
if ([string]::IsNullOrWhiteSpace($n)) { continue }
|
||||
try { Enable-NetAdapter -Name $n -Confirm:$false -ErrorAction Stop }
|
||||
catch { Write-Warning "Enable-NetAdapter '$n' failed: $_" }
|
||||
}
|
||||
Start-Sleep -Seconds 1
|
||||
Remove-Item $nicListFile -Force -ErrorAction SilentlyContinue
|
||||
} catch {
|
||||
Write-Warning "Re-enable wired NICs failed: $_"
|
||||
}
|
||||
}
|
||||
|
||||
Ensure-SendPxeStatus
|
||||
if (Get-Command Send-PxeStatus -ErrorAction SilentlyContinue) {
|
||||
try {
|
||||
Send-PxeStatus -Stage 'Monitor-IntuneProgress: Intune Device ID captured' `
|
||||
-StageIndex 7 -StageTotal 8 `
|
||||
-IntuneDeviceId $script:cache.DeviceId
|
||||
$script:cache.DeviceIdReported = $true
|
||||
} catch { }
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
|
||||
Reference in New Issue