Renumber PXE LAN from 10.9.100.0/24 to 172.16.9.0/24
Single-site bay-stuck issue at WJ: GE Intune Report IP script filters
Get-NetIPAddress on StartsWith("10.") and posts everything matching
to the GE Tines webhook. Bays at WJ get the PXE LAN 10.9.100.x IP
captured and reported -> GE backend tags bays as on a non-corp 10.x
subnet -> dynamic group eligibility for SFLD policy never matches.
Other GE sites work because their PXE LANs aren't on 10.x at all.
Renumber PXE LAN to RFC1918 172.16.9.0/24 so the GE filter naturally
skips wired PXE addresses without any disable-NIC dance.
Server-side already in flight (netplan dual-bound, dnsmasq scope +
boot URL repointed, blancco preferences + grub.cfg + iPXE GetPxeScript
all sed'd to 172.16.9.1). This commit is the playbook / scripts /
docs side: 109 hits across 35 files sed'd in one shot.
After this lands + boot.wim is rebuilt + bays renumber off DHCP,
the 10.9.100.1 binding will be dropped from netplan as the final
cleanup step.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
This commit is contained in:
@@ -36,7 +36,7 @@ $siteConfig = Get-SiteConfig
|
||||
$siteName = if ($siteConfig) { $siteConfig.siteName } else { 'West Jefferson' }
|
||||
$siteNameCompact = if ($siteConfig) { $siteConfig.siteNameCompact } else { 'WestJefferson' }
|
||||
|
||||
$edncDir = "C:\Enrollment\shopfloor-setup\Standard\eDNC"
|
||||
$edncDir = Join-Path $PSScriptRoot 'eDNC'
|
||||
|
||||
if (-not (Test-Path $edncDir)) {
|
||||
Write-Warning "eDNC folder not found at $edncDir - skipping."
|
||||
|
||||
Reference in New Issue