Renumber PXE LAN from 10.9.100.0/24 to 172.16.9.0/24
Single-site bay-stuck issue at WJ: GE Intune Report IP script filters
Get-NetIPAddress on StartsWith("10.") and posts everything matching
to the GE Tines webhook. Bays at WJ get the PXE LAN 10.9.100.x IP
captured and reported -> GE backend tags bays as on a non-corp 10.x
subnet -> dynamic group eligibility for SFLD policy never matches.
Other GE sites work because their PXE LANs aren't on 10.x at all.
Renumber PXE LAN to RFC1918 172.16.9.0/24 so the GE filter naturally
skips wired PXE addresses without any disable-NIC dance.
Server-side already in flight (netplan dual-bound, dnsmasq scope +
boot URL repointed, blancco preferences + grub.cfg + iPXE GetPxeScript
all sed'd to 172.16.9.1). This commit is the playbook / scripts /
docs side: 109 hits across 35 files sed'd in one shot.
After this lands + boot.wim is rebuilt + bays renumber off DHCP,
the 10.9.100.1 binding will be dropped from netplan as the final
cleanup step.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
This commit is contained in:
@@ -98,6 +98,30 @@
|
||||
]
|
||||
},
|
||||
|
||||
"gea-shopfloor-nocollections": {
|
||||
"_comment": "Shopfloor PC running eDNC + NTLARS + Defect Tracker but no UDC (no Collections). Same as Standard-Machine minus UDC pin/desktop/startup. Direct profile lookup (line 92 in Get-PCProfile.ps1) finds this BEFORE the alias-group fallback to Standard-Machine, so Standard-Machine's UDC entries do not leak through.",
|
||||
"machineappsSharePath": "\\\\tsgwp00525.wjs.geaerospace.net\\shared\\dt\\shopfloor\\main\\machineapps",
|
||||
"ntlarsBackupSharePath": "\\\\tsgwp00525.wjs.geaerospace.net\\shared\\dt\\shopfloor\\main\\ntlars-backups",
|
||||
"startupItems": [
|
||||
{ "label": "WJ Shopfloor", "type": "existing", "sourceLnk": "WJ Shopfloor.lnk" },
|
||||
{ "label": "Plant Apps", "type": "url", "urlKey": "plantApps" },
|
||||
{ "label": "eDNC", "type": "exe", "target": "C:\\Program Files (x86)\\Dnc\\bin\\DncMain.exe" }
|
||||
],
|
||||
"taskbarPins": [
|
||||
{ "name": "Microsoft Edge", "lnkPath": "%ALLUSERSPROFILE%\\Microsoft\\Windows\\Start Menu\\Programs\\Microsoft Edge.lnk" },
|
||||
{ "name": "WJ Shopfloor", "lnkPath": "%PUBLIC%\\Desktop\\Shopfloor Tools\\WJ Shopfloor.lnk" },
|
||||
{ "name": "eDNC", "lnkPath": "%PUBLIC%\\Desktop\\Shopfloor Tools\\eDNC.lnk" },
|
||||
{ "name": "NTLARS", "lnkPath": "%PUBLIC%\\Desktop\\Shopfloor Tools\\NTLARS.lnk" },
|
||||
{ "name": "Defect_Tracker", "lnkPath": "%PUBLIC%\\Desktop\\Shopfloor Tools\\Defect_Tracker.lnk" }
|
||||
],
|
||||
"desktopApps": [
|
||||
{ "name": "eDNC", "kind": "exe", "exePath": "C:\\Program Files (x86)\\Dnc\\bin\\DncMain.exe" },
|
||||
{ "name": "NTLARS", "kind": "exe", "exePath": "C:\\Program Files (x86)\\Dnc\\Common\\NTLARS.exe" },
|
||||
{ "name": "WJ Shopfloor", "kind": "existing", "sourceName": "WJ Shopfloor.lnk" },
|
||||
{ "name": "Defect_Tracker", "kind": "exe", "exePath": "C:\\Program Files (x86)\\WJF_Defect_Tracker\\Defect_Tracker.exe" }
|
||||
]
|
||||
},
|
||||
|
||||
"CMM": {
|
||||
"_comment": "Hexagon CMM apps (CLM 1.8, goCMM, PC-DMIS 2016, PC-DMIS 2019 R2). At imaging time they install from a WinPE-staged local bootstrap at C:\\CMM-Install (put there by startnet.cmd when pc-type=CMM, source is the PXE server enrollment share). Post-imaging, the unified GE-Enforce dispatcher reads cmm/manifest.json on the tsgwp00525 share below and enforces versions on every user logon (the SFLD creds Azure DSC provisions unlock the mount). cmmSharePath is the ongoing-enforcement source, not the imaging-time source.",
|
||||
"cmmSharePath": "\\\\tsgwp00525.wjs.geaerospace.net\\shared\\dt\\shopfloor\\cmm\\machineapps",
|
||||
|
||||
Reference in New Issue