Move wired-disable from stage 2 to post-PPKG-return
Push stages 2-6 to dashboard before going dark. Wired stays up through PPKG enrollment so all standard imaging progress lights up the dashboard card. Disable fires AFTER idx=6 push (handoff to Monitor PostPpkg) + BEFORE PostPpkg settle's Schedule #3 hammer + BEFORE the PPKG-driven reboot + BEFORE IME starts firing Report IP. Result: dashboard shows 2-6 cleanly, dark from 6 to 7, then catches up at 7 with QR. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
This commit is contained in:
@@ -41,23 +41,6 @@ function Report-Stage {
|
|||||||
}
|
}
|
||||||
Report-Stage -Stage 'Run-ShopfloorSetup: starting' -Index 2
|
Report-Stage -Stage 'Run-ShopfloorSetup: starting' -Index 2
|
||||||
|
|
||||||
# Kill wired NICs immediately after stage 2 push. Goal: GE Intune Report
|
|
||||||
# IP webhook only ever sees this bay's corp-WiFi IP, never the PXE LAN
|
|
||||||
# (10.9.100.x) IP. Otherwise GE backend tags the bay "not on corp net"
|
|
||||||
# and dynamic-group assignment filters exclude it from the SFLD
|
|
||||||
# ConfigurationProfile -> Phase 2 stuck forever.
|
|
||||||
# Monitor-IntuneProgress re-enables wired once
|
|
||||||
# C:\Logs\GE_Report_IP_Address*.txt appears (proof the webhook fire saw
|
|
||||||
# the corp IP it needed). Side effect during disabled window:
|
|
||||||
# Send-PxeStatus pushes from stages 3-6 fail silently (PXE server lives
|
|
||||||
# on the air-gapped 10.9.100.0/24 LAN). Dashboard catches up at idx=7.
|
|
||||||
$disableWiredScript = Join-Path $PSScriptRoot 'shopfloor-setup\Shopfloor\lib\Disable-WiredNics.ps1'
|
|
||||||
if (Test-Path -LiteralPath $disableWiredScript) {
|
|
||||||
try { & $disableWiredScript } catch { Write-Warning "Disable-WiredNics threw: $_" }
|
|
||||||
} else {
|
|
||||||
Write-Warning "Disable-WiredNics.ps1 not found at $disableWiredScript - wired stays up (Report IP leak risk)"
|
|
||||||
}
|
|
||||||
|
|
||||||
# AutoLogonCount is NOT set here. Previously we bumped it to 99/4, but
|
# AutoLogonCount is NOT set here. Previously we bumped it to 99/4, but
|
||||||
# Windows decrements it per-logon and at 0 clears AutoAdminLogon -- which
|
# Windows decrements it per-logon and at 0 clears AutoAdminLogon -- which
|
||||||
# nukes the lockdown-configured ShopFloor autologon later in the chain.
|
# nukes the lockdown-configured ShopFloor autologon later in the chain.
|
||||||
@@ -493,13 +476,24 @@ if (Test-Path -LiteralPath $enrollScript) {
|
|||||||
try { Stop-Transcript | Out-Null } catch {}
|
try { Stop-Transcript | Out-Null } catch {}
|
||||||
& $enrollScript
|
& $enrollScript
|
||||||
|
|
||||||
# PPKG completes -> we're back here with a pending shutdown timer.
|
# idx=6 push happens BEFORE wired disable so the dashboard captures
|
||||||
# Hand off to Monitor in -PostPpkg mode. Monitor cancels the shutdown,
|
# the handoff stage. Disable-WiredNics comes right after - kills wired
|
||||||
# settles, renders live status, then issues its own reboot. The
|
# before PostPpkg settle's Schedule #3 hammer hits Intune endpoints,
|
||||||
# persistent @logon sync_intune task fires on the next boot to resume
|
# before the PPKG-driven reboot, and before IME starts firing the
|
||||||
# tracking through device-category-assignment + lockdown.
|
# Report IP script. Goal: GE's Report IP webhook only ever sees the
|
||||||
|
# corp-WiFi IP, never PXE LAN (10.9.100.x). Monitor-IntuneProgress
|
||||||
|
# re-enables wired once C:\Logs\GE_Report_IP_Address*.txt shows up
|
||||||
|
# (proof of clean Report IP fire) and then pushes idx=7.
|
||||||
Write-Host ""
|
Write-Host ""
|
||||||
Report-Stage -Stage 'Run-ShopfloorSetup: handoff to Monitor-IntuneProgress' -Index 6
|
Report-Stage -Stage 'Run-ShopfloorSetup: handoff to Monitor-IntuneProgress' -Index 6
|
||||||
|
|
||||||
|
$disableWiredScript = Join-Path $PSScriptRoot 'shopfloor-setup\Shopfloor\lib\Disable-WiredNics.ps1'
|
||||||
|
if (Test-Path -LiteralPath $disableWiredScript) {
|
||||||
|
try { & $disableWiredScript } catch { Write-Warning "Disable-WiredNics threw: $_" }
|
||||||
|
} else {
|
||||||
|
Write-Warning "Disable-WiredNics.ps1 not found at $disableWiredScript - wired stays up (Report IP leak risk)"
|
||||||
|
}
|
||||||
|
|
||||||
Write-Host "=== Handing off to Monitor-IntuneProgress -PostPpkg ==="
|
Write-Host "=== Handing off to Monitor-IntuneProgress -PostPpkg ==="
|
||||||
cmd /c "shutdown /a 2>nul" | Out-Null
|
cmd /c "shutdown /a 2>nul" | Out-Null
|
||||||
$monitor = Join-Path $setupDir 'Shopfloor\lib\Monitor-IntuneProgress.ps1'
|
$monitor = Join-Path $setupDir 'Shopfloor\lib\Monitor-IntuneProgress.ps1'
|
||||||
|
|||||||
Reference in New Issue