CMM test iteration: desktop shortcuts, rename to 09-Setup-*, defer NIC re-enable
Rolls up everything from the CMM imaging test iteration tonight. No
single concern - several small, related polish items on the option-3
patched-MSI pipeline and the shopfloor-setup / sync_intune handoff.
- Rename all type-specific "01-Setup-<Type>.ps1" scripts to
"09-Setup-<Type>.ps1" across CMM, Display, Genspect, Keyence, Lab,
and WaxAndTrace. The "01-" prefix implied the script runs first in
the overall sequence when it actually runs between baseline (00, 04)
and finalization (06, 07). Logs now read "Running CMM setup:
09-Setup-CMM.ps1" which matches the real position. Standard/
01-eDNC.ps1 + 02-MachineNumberACLs.ps1 left alone - those digits
represent real within-type ordering.
- playbook/shopfloor-setup/site-config.json CMM profile updates:
- startupItems = [] (empty). Previously had WJ Shopfloor auto-launch
which the user does not want on CMM workstations. Now relies on
the Get-ProfileValue empty-array fix to not fall through to site
defaults.
- desktopApps + taskbarPins gain entries for PC-DMIS 2016, PC-DMIS
2019 R2, CLM Admin, and goCMM so 06-OrganizeDesktop Phase 2
materializes them into C:\\Users\\Public\\Desktop\\Shopfloor Tools\\
and 07-TaskbarLayout pins them. goCMM is under C:\\Program Files
(x86)\\General Electric\\goCMM\\ (GE product, not Hexagon).
- playbook/shopfloor-setup/Run-ShopfloorSetup.ps1: remove the blocking
"UNPLUG ethernet cable, press any key" prompt + the interactive
wired-NIC re-enable. The whole prompt block was a hard blocker on
the imaging chain that required a human to walk to each PC.
- playbook/shopfloor-setup/Shopfloor/lib/Monitor-IntuneProgress.ps1:
re-enable wired NICs unconditionally at the top of the transcript.
This is the new home for the re-enable that used to live behind the
prompt in Run-ShopfloorSetup. By the time sync_intune fires (after
PPKG reboot + auto-login + Stage-Dispatcher), the tech has had
minutes of wall-clock time to physically rewire from PXE to
production without us blocking on a keypress. Tower case is a
no-op because migrate-to-wifi.ps1 already left wired enabled.
- Internal comment updates in 09-Setup-CMM.ps1, cmm-manifest.json,
Install-FromManifest.ps1, and startnet.cmd (+ startnet-template)
to reflect the new filename.
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
This commit is contained in:
45
playbook/shopfloor-setup/Display/09-Setup-Display.ps1
Normal file
45
playbook/shopfloor-setup/Display/09-Setup-Display.ps1
Normal file
@@ -0,0 +1,45 @@
|
||||
# 09-Setup-Display.ps1 -- Display-specific setup (runs after Shopfloor baseline)
|
||||
# Reads display-type.txt to install either LobbyDisplay or Dashboard kiosk app.
|
||||
|
||||
$enrollDir = "C:\Enrollment"
|
||||
$typeFile = Join-Path $enrollDir "display-type.txt"
|
||||
$setupDir = Split-Path -Parent $MyInvocation.MyCommand.Path
|
||||
|
||||
if (-not (Test-Path $typeFile)) {
|
||||
Write-Warning "No display-type.txt found - skipping display setup."
|
||||
return
|
||||
}
|
||||
|
||||
$displayType = (Get-Content $typeFile -First 1).Trim()
|
||||
Write-Host "=== Display Setup: $displayType ==="
|
||||
|
||||
switch ($displayType) {
|
||||
"Lobby" {
|
||||
$installer = Join-Path $setupDir "GEAerospaceLobbyDisplaySetup.exe"
|
||||
$appName = "Lobby Display"
|
||||
}
|
||||
"Dashboard" {
|
||||
$installer = Join-Path $setupDir "GEAerospaceDashboardSetup.exe"
|
||||
$appName = "Dashboard"
|
||||
}
|
||||
default {
|
||||
Write-Warning "Unknown display type: $displayType"
|
||||
return
|
||||
}
|
||||
}
|
||||
|
||||
if (-not (Test-Path $installer)) {
|
||||
Write-Warning "$appName installer not found at $installer - skipping."
|
||||
return
|
||||
}
|
||||
|
||||
Write-Host "Installing $appName..."
|
||||
$proc = Start-Process -FilePath $installer -ArgumentList '/VERYSILENT', '/SUPPRESSMSGBOXES', '/NORESTART', "/LOG=C:\Enrollment\$appName-install.log" -Wait -PassThru
|
||||
|
||||
if ($proc.ExitCode -eq 0) {
|
||||
Write-Host "$appName installed successfully."
|
||||
} else {
|
||||
Write-Warning "$appName exited with code $($proc.ExitCode). Check C:\Enrollment\$appName-install.log"
|
||||
}
|
||||
|
||||
Write-Host "=== Display Setup Complete ==="
|
||||
Reference in New Issue