CMM test iteration: desktop shortcuts, rename to 09-Setup-*, defer NIC re-enable
Rolls up everything from the CMM imaging test iteration tonight. No
single concern - several small, related polish items on the option-3
patched-MSI pipeline and the shopfloor-setup / sync_intune handoff.
- Rename all type-specific "01-Setup-<Type>.ps1" scripts to
"09-Setup-<Type>.ps1" across CMM, Display, Genspect, Keyence, Lab,
and WaxAndTrace. The "01-" prefix implied the script runs first in
the overall sequence when it actually runs between baseline (00, 04)
and finalization (06, 07). Logs now read "Running CMM setup:
09-Setup-CMM.ps1" which matches the real position. Standard/
01-eDNC.ps1 + 02-MachineNumberACLs.ps1 left alone - those digits
represent real within-type ordering.
- playbook/shopfloor-setup/site-config.json CMM profile updates:
- startupItems = [] (empty). Previously had WJ Shopfloor auto-launch
which the user does not want on CMM workstations. Now relies on
the Get-ProfileValue empty-array fix to not fall through to site
defaults.
- desktopApps + taskbarPins gain entries for PC-DMIS 2016, PC-DMIS
2019 R2, CLM Admin, and goCMM so 06-OrganizeDesktop Phase 2
materializes them into C:\\Users\\Public\\Desktop\\Shopfloor Tools\\
and 07-TaskbarLayout pins them. goCMM is under C:\\Program Files
(x86)\\General Electric\\goCMM\\ (GE product, not Hexagon).
- playbook/shopfloor-setup/Run-ShopfloorSetup.ps1: remove the blocking
"UNPLUG ethernet cable, press any key" prompt + the interactive
wired-NIC re-enable. The whole prompt block was a hard blocker on
the imaging chain that required a human to walk to each PC.
- playbook/shopfloor-setup/Shopfloor/lib/Monitor-IntuneProgress.ps1:
re-enable wired NICs unconditionally at the top of the transcript.
This is the new home for the re-enable that used to live behind the
prompt in Run-ShopfloorSetup. By the time sync_intune fires (after
PPKG reboot + auto-login + Stage-Dispatcher), the tech has had
minutes of wall-clock time to physically rewire from PXE to
production without us blocking on a keypress. Tower case is a
no-op because migrate-to-wifi.ps1 already left wired enabled.
- Internal comment updates in 09-Setup-CMM.ps1, cmm-manifest.json,
Install-FromManifest.ps1, and startnet.cmd (+ startnet-template)
to reflect the new filename.
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
This commit is contained in:
@@ -99,17 +99,23 @@
|
||||
"CMM": {
|
||||
"_comment": "Hexagon CMM apps (CLM 1.8, goCMM, PC-DMIS 2016, PC-DMIS 2019 R2). At imaging time they install from a WinPE-staged local bootstrap at C:\\CMM-Install (put there by startnet.cmd when pc-type=CMM, source is the PXE server enrollment share). Post-imaging, the 'GE CMM Enforce' scheduled task runs CMM-Enforce.ps1 on user logon and enforces versions against the tsgwp00525 share below (the SFLD creds Azure DSC provisions unlock the mount). cmmSharePath is the ongoing-enforcement source, not the imaging-time source.",
|
||||
"cmmSharePath": "\\\\tsgwp00525.wjs.geaerospace.net\\shared\\dt\\shopfloor\\cmm\\machineapps",
|
||||
"startupItems": [
|
||||
{ "label": "WJ Shopfloor", "type": "existing", "sourceLnk": "WJ Shopfloor.lnk" }
|
||||
],
|
||||
"startupItems": [],
|
||||
"taskbarPins": [
|
||||
{ "name": "Microsoft Edge", "lnkPath": "%ALLUSERSPROFILE%\\Microsoft\\Windows\\Start Menu\\Programs\\Microsoft Edge.lnk" },
|
||||
{ "name": "WJ Shopfloor", "lnkPath": "%PUBLIC%\\Desktop\\Shopfloor Tools\\WJ Shopfloor.lnk" },
|
||||
{ "name": "Defect_Tracker", "lnkPath": "%PUBLIC%\\Desktop\\Shopfloor Tools\\Defect_Tracker.lnk" }
|
||||
{ "name": "WJ Shopfloor", "lnkPath": "%PUBLIC%\\Desktop\\Shopfloor Tools\\WJ Shopfloor.lnk" },
|
||||
{ "name": "Defect_Tracker", "lnkPath": "%PUBLIC%\\Desktop\\Shopfloor Tools\\Defect_Tracker.lnk" },
|
||||
{ "name": "PC-DMIS 2016", "lnkPath": "%PUBLIC%\\Desktop\\Shopfloor Tools\\PC-DMIS 2016.lnk" },
|
||||
{ "name": "PC-DMIS 2019 R2", "lnkPath": "%PUBLIC%\\Desktop\\Shopfloor Tools\\PC-DMIS 2019 R2.lnk" },
|
||||
{ "name": "CLM Admin", "lnkPath": "%PUBLIC%\\Desktop\\Shopfloor Tools\\CLM Admin.lnk" },
|
||||
{ "name": "goCMM", "lnkPath": "%PUBLIC%\\Desktop\\Shopfloor Tools\\goCMM.lnk" }
|
||||
],
|
||||
"desktopApps": [
|
||||
{ "name": "WJ Shopfloor", "kind": "existing", "sourceName": "WJ Shopfloor.lnk" },
|
||||
{ "name": "Defect_Tracker", "kind": "existing", "sourceName": "Defect_Tracker.lnk" }
|
||||
{ "name": "WJ Shopfloor", "kind": "existing", "sourceName": "WJ Shopfloor.lnk" },
|
||||
{ "name": "Defect_Tracker", "kind": "existing", "sourceName": "Defect_Tracker.lnk" },
|
||||
{ "name": "PC-DMIS 2016", "kind": "exe", "exePath": "C:\\Program Files\\Hexagon\\PC-DMIS 2016.0 64-bit\\PCDLRN.exe" },
|
||||
{ "name": "PC-DMIS 2019 R2", "kind": "exe", "exePath": "C:\\Program Files\\Hexagon\\PC-DMIS 2019 R2 64-bit\\PCDLRN.exe" },
|
||||
{ "name": "CLM Admin", "kind": "exe", "exePath": "C:\\Program Files\\Hexagon\\CLM Admin 1.8 64-bit\\clmadmin.exe" },
|
||||
{ "name": "goCMM", "kind": "exe", "exePath": "C:\\Program Files (x86)\\General Electric\\goCMM\\goCMM.exe" }
|
||||
],
|
||||
"edgeHomepage": "http://tsgwp00524.logon.ds.ge.com/",
|
||||