Commit Graph

7 Commits

Author SHA1 Message Date
cproudlock
04db6d6605 Generic build for other GE sites: no WJ data, one shopfloor type, Windows USB builder
Everything West Jefferson specific moved out to a separate repo
(pxe-site-wj): NTLARS/UDC/heat-treat backups keyed by WJ machine numbers,
CMM and Wax/Trace bay lists, WJ OpenText profiles, site-config.json, the
WJ preinstall list, and the WJ shopfloor PC types (Collections,
NoCollections, Common, Keyence, CMM, Genspect, HeatTreat, Wax/Trace,
Display, PartMarker) with GE-Enforce, machine numbers and the desktop
layout. The part-marker bench tools moved to their own repo. Dead
scripts removed: build-proxmox-iso, deploy-bios, sync_hardware_models,
mirror-from-gold, pull-bios, startnet-template.cmd.

Shopfloor is one generic type, gea-shopfloor-standard, with today's
timing:
- PPKG at first logon (unattend Order 10, unchanged).
- Install-AppList.ps1 runs C:\PreInstall\preinstall.json during setup.
- A new SYSTEM task, GE Shopfloor Post-PPKG, runs postppkg.json once
  after the post-PPKG reboot. It also clears AutoLogonCount after the
  ShopFloor handover (the Users-level monitor can be denied that HKLM
  write) and removes the Intune Sync task when done.
- Both lists ship empty. A site adds entries and installers.
- WinPE choice 3 goes straight to the PPKG menu. Staging, fetch and heal
  carry only the generic payload. The webapp's shopfloor sub-menu editor
  is gone, and the imaging tiles name the new stages.
- The playbook deploys the empty lists only if missing. It now deploys
  the PowerShell 7 MSI the shopfloor unattend installs, which it never
  did before.

Blancco site settings move into the webapp (Updates > Blancco releases):
business location, licensing Wi-Fi SSID and password. They are rendered
into the served preferences.xml and applied to every staged release, and
are seeded from site-vars (site_name, blancco_wifi_ssid,
blancco_wifi_password) only while none exist. The repo XML carries no
site values; the plaintext Wi-Fi password is gone from it.

New site_name and site_timezone settings: report and evidence-pack site
name, server clock and webapp time zone. No more West Jefferson defaults
in webapp/config.py or the dashboard title. Sync-BPRT.ps1 gets the
server address filled in at download instead of WJ's GE address.

USB on Windows:
- scripts/Build-PxeUsb.ps1 runs the same checks as build-usb.sh. It
  writes one FAT32 CIDATA partition (ISO files plus patched grub.cfg plus
  payload) with diskpart and reads every file back by SHA-256.
- Tested with Windows PowerShell 5.1 in the win11 VM, and the layout
  installs and first-boots in the pxetest VM.
- scripts/stage-usb-share.sh stages the build folder on a share.
- site-content/ is optional for both builders.

KB docs/kb/How_To_Deploy_PXE_Server_New_Site.html: new-site deployment,
Windows only, with a site-vars.yml guide.

Checks: webapp tests pass (5 suites); the unattend lint and playbook
syntax checks pass; every .ps1 parses; there are no WJ hosts, IPs, names
or PC types in playbook/, webapp/, scripts/ or autoinstall/.
2026-10-16 20:37:22 -04:00
cproudlock
bb08392b84 download-drivers: reuse an existing directory that differs only in case
Dell and GE manifests spell the same folder inconsistently - OptiPlex vs
Optiplex. Windows does not care, but the Samba share sits on a case-sensitive
filesystem, so a blind mkdir -p created a SECOND tree and the drivers split
between them.

That is exactly how the OptiPlex Micro 7020 pack went missing: the manifest asked
for OptiPlex/D13MLK while the 3.2 GB zip sat in Optiplex/D13MLK. PESetup found no
pack, logged a warning rather than an error, and the bay imaged with no network
drivers - so DNS failed at first boot and bulk enrollment could not reach the
CDN. Symptoms three steps from the cause.

mkdir_ci walks the path one component at a time and reuses whatever is already
there whatever its case, creating only genuinely new components. Callers must use
the RETURNED path, since it may differ in case from the requested one. Falls back
to plain mkdir -p rather than skipping a download if the resolve fails.

Both spellings still exist in the live catalogues; scripts/lint-driver-catalogue.py
reports a case mismatch as an error so the pair cannot silently drift again.
2026-08-06 14:38:54 -04:00
cproudlock
3b63697176 download-drivers: compare BIOS versions numerically, not as strings
parse_bios_catalog kept the 'latest' BIOS per model with a string compare, so e.g. '1.20.1' > '1.9.0' was False and it wrongly retained the older 1.9.0. Added _ver_tuple() and compare tuples of ints so the genuinely newest firmware wins.
2026-07-23 10:54:35 -04:00
cproudlock
ce604adcda Renumber PXE LAN from 10.9.100.0/24 to 172.16.9.0/24
Single-site bay-stuck issue at WJ: GE Intune Report IP script filters
Get-NetIPAddress on StartsWith("10.") and posts everything matching
to the GE Tines webhook. Bays at WJ get the PXE LAN 10.9.100.x IP
captured and reported -> GE backend tags bays as on a non-corp 10.x
subnet -> dynamic group eligibility for SFLD policy never matches.
Other GE sites work because their PXE LANs aren't on 10.x at all.

Renumber PXE LAN to RFC1918 172.16.9.0/24 so the GE filter naturally
skips wired PXE addresses without any disable-NIC dance.

Server-side already in flight (netplan dual-bound, dnsmasq scope +
boot URL repointed, blancco preferences + grub.cfg + iPXE GetPxeScript
all sed'd to 172.16.9.1). This commit is the playbook / scripts /
docs side: 109 hits across 35 files sed'd in one shot.

After this lands + boot.wim is rebuilt + bays renumber off DHCP,
the 10.9.100.1 binding will be dropped from netplan as the final
cleanup step.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-14 16:30:32 -04:00
cproudlock
ea93c3e08c download-drivers: fix BIOS push path + 3-col models.txt + don't overwrite
Three related fixes:

1. Hard-coded BIOS push path was /srv/samba/enrollment/BIOS, which does
   not exist on the live PXE server. Real path is the shared
   /srv/samba/winpeapps/_shared/BIOS/ where check-bios.cmd lives and
   playbook task pxe_server_setup.yml:485 deploys Flash64W.exe + the
   per-model BIOS .exe files.

2. Generated models.txt was 2-column (ModelSubstring|BIOSFile) but
   check-bios.cmd reads tokens=1,2,3 with delims=| and uses field 3
   for the version compare. Without the 3rd column, the version-skip
   logic never engages and every imaged PC re-flashes BIOS on every
   boot. Now writes 3-column (ModelSubstring|BIOSFile|Version).

3. The script overwrote the live models.txt with only the entries it
   touched in the current run. Live had 50+ entries; a single-model
   run wiped the other 49. Now prints the lines and asks the operator
   to merge them into playbook/shopfloor-setup/BIOS/models.txt and
   re-deploy via scripts/deploy-bios.sh.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-08 17:23:21 -04:00
cproudlock
712fa4fd3e download-drivers.py: strip CRLF line endings
Shebang was \`#!/usr/bin/env python3\r\` which errored with
\`/usr/bin/env: python3\r: No such file or directory\`. Pure line-ending
fix, no content change.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-22 18:04:02 -04:00
cproudlock
d6776f7c7f Reorganize repo, enrollment share taxonomy, Blancco USB-build fixes, v4.10 PPKGs
Workstation reorganization:
- All build/deploy/helper scripts moved into scripts/ (paths updated to use
  REPO_ROOT instead of SCRIPT_DIR so they resolve sibling dirs from the new
  depth)
- New config/ directory placeholder for site-specific overrides
- Removed stale: mok-keys/, test-vm.sh, test-lab.sh, setup-guide-original.txt,
  unattend/ (duplicate of moved playbook/FlatUnattendW10.xml)
- README.md and SETUP.md structure listings updated, dead "Testing with KVM"
  section removed
- .claude/ gitignored

Enrollment share internal taxonomy (forward-looking; existing servers
unaffected since they keep their current boot.wim with flat paths):
- Single SMB share kept (WinPE only mounts one Y: drive), but content now
  organised into ppkgs/, scripts/, config/, shopfloor-setup/, pre-install/{bios,
  installers}, installers-post/cmm/, blancco/, logs/
- README.md deployed to share root explaining each subdir
- New playbook tasks deploy site-config.json + wait-for-internet.ps1 +
  migrate-to-wifi.ps1 explicitly (were ad-hoc on legacy servers)
- BIOS subdir moved into pre-install/bios/, preinstall/ renamed to pre-install/
- startnet.cmd + startnet-template.cmd updated with new Y:\subdir\ paths
- Bumped GCCH PPKG references v4.9 -> v4.10

Blancco USB-build fixes (so next fresh USB install boots Blancco end-to-end
without the manual fixup we did against GOLD):
- grub-blancco.cfg: kernel/initrd switched HTTP -> TFTP (GRUB's HTTP module
  times out on multi-MB files); added modprobe.blacklist=iwlwifi,iwlmvm,btusb
  (WiFi drivers hang udev on Intel business PCs)
- grubx64.efi rebuilt from updated cfg
- Playbook task added to create /srv/tftp/blancco/ symlinks pointing at the
  HTTP-served binaries

run-enrollment.ps1: OOBEComplete is now set AFTER PPKG install (Win11 22H2+
hangs indefinitely if OOBEComplete is set before the bulk-enrollment PPKG runs).

Also includes deploy-bios.sh / pull-bios.sh / busybox-static / models.txt
that were sitting untracked at the repo root.
2026-04-14 16:01:02 -04:00