Commit Graph

3 Commits

Author SHA1 Message Date
cproudlock
0aaf049942 Extract site-specific values to site-config.json
New site-config.json file at C:\Enrollment\ (staged by startnet.cmd from
the enrollment share) contains all West Jefferson-specific values that were
previously hardcoded across 7 scripts. To deploy at a different GE site,
clone site-config.json and change the values - scripts need zero changes.

Config schema (v1.0):
  siteName / siteNameCompact  - UDC/eDNC site args
  urls{}                      - Edge startup tab fallback URLs
  edgeStartupTabs[]           - ordered tab list with .url file basenames
  opentext{}                  - excluded .hep profiles and .lnk shortcuts
  startupItems[]              - Configure-PC toggle list (exe/existing/url)
  taskbarPins[]               - 07-TaskbarLayout pin order with lnk paths
  desktopApps[]               - 06-OrganizeDesktop Phase 2 app list

Every script uses the same inline Get-SiteConfig helper that reads the
JSON and returns $null if missing/corrupt. All consumers fall back to the
current hardcoded West Jefferson defaults when $siteConfig is null, so
PXE servers without a site-config.json continue working identically.

Scripts updated:
  06-OrganizeDesktop.ps1   - desktopApps array from config
  07-TaskbarLayout.ps1     - pinSpec array from config
  08-EdgeDefaultBrowser.ps1 - startup tab loop from config
  Configure-PC.ps1         - startup items + site name from config
  Check-MachineNumber.ps1  - site name from config
  Set-MachineNumber.ps1    - site name from config
  01-eDNC.ps1              - siteName + siteNameCompact from config
  startnet.cmd             - copies site-config.json from enrollment share

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-10 11:11:35 -04:00
cproudlock
ded0a7184b Shopfloor scripts: em-dash to hyphen, add positional Level param
Replace em-dash characters with plain hyphens across the 5 shopfloor
setup scripts (avoids cp1252 mojibake in .bat files and keeps the
PowerShell sources consistent). Also adds [Parameter(Position=1)] to
Write-PreInstallLog so the Level argument can be passed positionally.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-08 14:24:37 -04:00
cproudlock
a1a78e2ba3 PXE preinstall pipeline + Set-MachineNumber helper for Standard PCs
Adds a local-install pipeline so Standard shopfloor PCs get Oracle, the
VC++ redists (2008-2022), and UDC installed during PXE imaging via Samba
instead of pulling ~215 MB per device from Azure blob over the corporate
WAN. Intune DSC then verifies (already-installed apps are skipped) and
the only Azure traffic on the happy path is ~11 KB of CustomScripts
wrapper polling.

New files:
- playbook/preinstall/preinstall.json — curated app list with PCTypes
  filter and per-app detection rules. Install order puts VC++ 2008
  LAST so its (formerly) reboot-triggering bootstrapper doesn't kill
  the runner mid-loop. (2008 itself now uses extracted vc_red.msi with
  REBOOT=ReallySuppress; the reorder is defense in depth.)
- playbook/shopfloor-setup/Shopfloor/00-PreInstall-MachineApps.ps1 —
  the runner. Numbered 00- so it runs first in the baseline sequence.
  Reads preinstall.json, filters by PCTYPE, polls for completion via
  detection check (handles UDC's hung WPF process by killing it once
  detection passes), uses synchronous WriteThrough logging that
  survives hard reboots, preserves log history across runs.
- playbook/shopfloor-setup/Standard/Set-MachineNumber.{ps1,bat} — desktop
  helper for SupportUser. Reads current UDC + eDNC machine numbers,
  prompts via VB InputBox, validates digits-only, kills running UDC,
  edits both C:\ProgramData\UDC\udc_settings.json and HKLM\…\GE Aircraft
  Engines\DNC\General\MachineNo, relaunches UDC. Lets a tech assign a
  real machine number to a mass-produced PC without admin/LAPS.
- playbook/sync-preinstall.sh — workstation helper to push installer
  binaries from /home/camp/pxe-images/main/ to the live PXE Samba.

Changes:
- playbook/startnet.cmd + startnet-template.cmd — add xcopy to stage
  preinstall bundle from Y:\preinstall\ to W:\PreInstall\ during the
  WinPE imaging phase, gated on PCTYPE being set.
- playbook/pxe_server_setup.yml — create /srv/samba/enrollment/preinstall
  + installers/ directories and deploy preinstall.json there.
- playbook/shopfloor-setup/Run-ShopfloorSetup.ps1 — bump AutoLogonCount
  to 99 at start (defense against any installer triggering an immediate
  reboot mid-dispatcher; final line still resets to 2 on successful
  completion). Copy Set-MachineNumber.{ps1,bat} to SupportUser desktop
  on Standard PCs.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-08 14:06:26 -04:00