Two related changes so the /imaging dashboard reaches 100% and so the
operator can see why POSTs are not arriving when a session stalls.
Monitor-IntuneProgress.ps1:
* After sync-complete.txt is written (DSC + lockdown done) fire a
final Send-PxeStatus -StageIndex 8 -StageTotal 8 -Status 'succeeded'
+ IntuneDeviceId. Previously the script exited without any final
status push, so even a perfect run capped at idx=7 / 87.5%. The
session now reaches 8/8 / 100% green when imaging actually finishes.
Send-PxeStatus.ps1:
* Log EVERY POST attempt (both success and failure) to C:\Logs\
send-pxe-status.log with idx, status, stage name, and either the
HTTP code on success or the exception message on failure. Was
previously silent-on-success, log-on-failure. Operator can now
correlate dashboard state to actual outbound activity:
OK idx=2/8 status=in_progress http=200 stage='Run-ShopfloorSetup: starting'
ERR idx=2/8 status=in_progress uri=http://10.9.100.1:9009/... err=Unable to connect
* Errors still swallowed - imaging never blocks on a failed status push.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Adds end-to-end progress tracking for PXE imaging sessions and surfaces
each Blancco report's BIOS serial in the report list.
webapp:
* services/imaging_status.py - JSON-per-serial state store under
IMAGING_DIR (default /var/log/pxe-imaging). Atomic write via
tempfile + rename. log_tail capped at 50 lines. Merges partial
updates so clients can post just the current_stage tick.
* config.py - new IMAGING_DIR env-overridable path.
* services/csrf.py - explicit exempt list for machine-to-machine
endpoints; /imaging/status is the first entry. Air-gapped LAN;
trust-by-network for client posts.
* app.py - four new routes:
GET /imaging dashboard (renders all sessions)
POST /imaging/status client status push (JSON body)
GET /imaging/<serial>.json raw session JSON for ad-hoc polling
POST /imaging/delete/<s> clear a session from the dashboard
Also parses each Blancco XML in the /reports list to surface
system.serial + system.model columns.
* templates/imaging.html - Bootstrap dashboard with per-session
cards (state badge, progress bar, stage idx/total, mac, elapsed,
log tail). meta http-equiv refresh=5 for auto-tick.
* templates/base.html - new "Imaging Progress" nav entry.
* templates/reports.html - Serial + Model columns added.
playbook:
* shopfloor-setup/Shopfloor/lib/Send-PxeStatus.ps1 - new helper.
Dot-source this then call Send-PxeStatus -Stage X -StageIndex N
-StageTotal M from any stage script. BIOS serial via CIM, MAC via
Get-NetAdapter, pctype + machinenumber from C:\Enrollment.
Failures are swallowed to a local log so a network blip doesn't
block imaging.
* shopfloor-setup/Run-ShopfloorSetup.ps1 - dot-sources helper +
posts at three coarse milestones (start, PPKG enrollment,
handoff to Monitor-IntuneProgress).
* shopfloor-setup/gea-shopfloor-keyence/09-Setup-Keyence.ps1 -
posts at session start + after Install-FromManifest with
succeeded/failed status derived from $rc. Other 09-Setup-*.ps1
scripts can follow the same pattern.
ID is BIOS serial (stable across WinPE -> Windows transition and
across reboots, unlike hostname which is random pre-PPKG). Operator
already knows the serial of the bay they imaged.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>