cproudlock
8cd0c147d8 imaging: renumber stages to be time-monotonic (1=WinPE, 7=Intune ID)
Previously the stage indices reflected logical milestones but not the
order they fire in. Run-ShopfloorSetup posted idx=1 (start) and idx=4
(PPKG) - but 09-Setup-Keyence (inside per-type loop) ran BETWEEN them
and posted idx=5/6. The dashboard then "regressed" from 6 back to 4
when PPKG fired, making it look stuck at the per-type-complete card.

New numbering matches actual execution order:

  1 - WinPE: PESetup / WIM apply              (startnet.cmd)
  2 - Run-ShopfloorSetup: starting            (Run-ShopfloorSetup.ps1)
  3 - 09-Setup-<Type>: starting               (per-type)
  4 - 09-Setup-<Type>: complete               (per-type)
  5 - Run-ShopfloorSetup: PPKG enrollment     (Run-ShopfloorSetup.ps1)
  6 - Run-ShopfloorSetup: handoff to Monitor  (Run-ShopfloorSetup.ps1)
  7 - Monitor-IntuneProgress: Intune Device ID captured

services/imaging_status.py rewind threshold reverts to stage_index <= 1
now that WinPE startnet posts idx=1.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-13 11:34:01 -04:00
cproudlock
9122b28c31 webapp: imaging progress dashboard + serial column on reports list
Adds end-to-end progress tracking for PXE imaging sessions and surfaces
each Blancco report's BIOS serial in the report list.

webapp:
  * services/imaging_status.py - JSON-per-serial state store under
    IMAGING_DIR (default /var/log/pxe-imaging). Atomic write via
    tempfile + rename. log_tail capped at 50 lines. Merges partial
    updates so clients can post just the current_stage tick.
  * config.py - new IMAGING_DIR env-overridable path.
  * services/csrf.py - explicit exempt list for machine-to-machine
    endpoints; /imaging/status is the first entry. Air-gapped LAN;
    trust-by-network for client posts.
  * app.py - four new routes:
      GET  /imaging               dashboard (renders all sessions)
      POST /imaging/status        client status push (JSON body)
      GET  /imaging/<serial>.json raw session JSON for ad-hoc polling
      POST /imaging/delete/<s>    clear a session from the dashboard
    Also parses each Blancco XML in the /reports list to surface
    system.serial + system.model columns.
  * templates/imaging.html - Bootstrap dashboard with per-session
    cards (state badge, progress bar, stage idx/total, mac, elapsed,
    log tail). meta http-equiv refresh=5 for auto-tick.
  * templates/base.html - new "Imaging Progress" nav entry.
  * templates/reports.html - Serial + Model columns added.

playbook:
  * shopfloor-setup/Shopfloor/lib/Send-PxeStatus.ps1 - new helper.
    Dot-source this then call Send-PxeStatus -Stage X -StageIndex N
    -StageTotal M from any stage script. BIOS serial via CIM, MAC via
    Get-NetAdapter, pctype + machinenumber from C:\Enrollment.
    Failures are swallowed to a local log so a network blip doesn't
    block imaging.
  * shopfloor-setup/Run-ShopfloorSetup.ps1 - dot-sources helper +
    posts at three coarse milestones (start, PPKG enrollment,
    handoff to Monitor-IntuneProgress).
  * shopfloor-setup/gea-shopfloor-keyence/09-Setup-Keyence.ps1 -
    posts at session start + after Install-FromManifest with
    succeeded/failed status derived from $rc. Other 09-Setup-*.ps1
    scripts can follow the same pattern.

ID is BIOS serial (stable across WinPE -> Windows transition and
across reboots, unlike hostname which is random pre-PPKG). Operator
already knows the serial of the bay they imaged.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-13 10:07:18 -04:00
cproudlock
6dcf96e40a Phase 3+4 rename reorg: repo dir renames + startnet.cmd menu
Pairs with Phase 1+2 from earlier (alias maps in Install-FromManifest,
GE-Enforce, Get-PCProfile, verify-state). See project-shopfloor-rename-reorg
memory for the plan.

Phase 3 (repo + paths):
- git mv per-PC-type dirs to gea-shopfloor-* names:
    Standard      -> gea-shopfloor-collections
    CMM           -> gea-shopfloor-cmm
    Keyence       -> gea-shopfloor-keyence
    Genspect      -> gea-shopfloor-genspect
    WaxAndTrace   -> gea-shopfloor-waxtrace
    Display       -> gea-shopfloor-display
    Lab           -> gea-shopfloor-common (folded; Timeclock+Lab merge)
- New gea-shopfloor-nocollections/ (clone of collections sans UDC scripts).
- New gea-shopfloor-heattreat/ (placeholder, README only).
- Move Standard/ntlars-backups/ -> _ntlars-backups/ (per-MN, not per-type).
- Run-ShopfloorSetup.ps1: Resolve-PCTypeDir helper walks alias group when
  the on-disk dir for the current pcType is missing. Set-MachineNumber
  helper-copy gated on collections|nocollections|legacy Standard-Machine.
- Update-MachineNumber.ps1: pcProfiles lookups try gea-shopfloor-collections
  first, fall back to legacy Standard-Machine. PowerShell 5.1 compatible
  (no null-coalesce).

Phase 4 (startnet.cmd menu):
- Choice 3 "GEA Shopfloor" now drills into a 9-item sub-menu instead of
  going straight to enrollment. Sub-cats:
    1. Machine with Collections        -> gea-shopfloor-collections
    2. Machine without Collections     -> gea-shopfloor-nocollections
    3. Common (Timeclock, Lab)         -> gea-shopfloor-common
    4. Keyence                         -> gea-shopfloor-keyence
    5. CMM                             -> gea-shopfloor-cmm
    6. Genspect                        -> gea-shopfloor-genspect
    7. Heattreat                       -> gea-shopfloor-heattreat
    8. Wax and Trace                   -> gea-shopfloor-waxtrace
    9. Display                         -> gea-shopfloor-display
- Office menu (existing 6-option) follows for every sub-cat.
- Machine number prompt only for collections + nocollections.
- pc-subtype.txt + display-type.txt no longer written. PCTYPE is a
  single full string (gea-shopfloor-*); subtype-aware code paths fall
  back to empty and resolve via the alias map.
- CMM bootstrap stage gate switched from "%PCTYPE%"=="CMM" to
  "%PCTYPE%"=="gea-shopfloor-cmm".

Test harness:
- B-enforce/run.sh PCSUBTYPE default changed from "Machine" to "" so
  single-arg invocation matches the new single-string scheme. Two-arg
  legacy form ("Standard Machine") still works via aliasing.
- B-enforce/tamper.ps1 alias-aware Test-MatrixEntryMatches mirroring
  verify-state.ps1.

Smoke-tested on win11 VM as SYSTEM via qga: B-enforce harness 5-phase
cycle (stage / baseline / tamper / heal / idempotent) passes 10/10
with PCType=gea-shopfloor-collections AND with legacy "Standard Machine"
two-arg form.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-04 08:09:16 -04:00