Everything West Jefferson specific moved out to a separate repo
(pxe-site-wj): NTLARS/UDC/heat-treat backups keyed by WJ machine numbers,
CMM and Wax/Trace bay lists, WJ OpenText profiles, site-config.json, the
WJ preinstall list, and the WJ shopfloor PC types (Collections,
NoCollections, Common, Keyence, CMM, Genspect, HeatTreat, Wax/Trace,
Display, PartMarker) with GE-Enforce, machine numbers and the desktop
layout. The part-marker bench tools moved to their own repo. Dead
scripts removed: build-proxmox-iso, deploy-bios, sync_hardware_models,
mirror-from-gold, pull-bios, startnet-template.cmd.
Shopfloor is one generic type, gea-shopfloor-standard, with today's
timing:
- PPKG at first logon (unattend Order 10, unchanged).
- Install-AppList.ps1 runs C:\PreInstall\preinstall.json during setup.
- A new SYSTEM task, GE Shopfloor Post-PPKG, runs postppkg.json once
after the post-PPKG reboot. It also clears AutoLogonCount after the
ShopFloor handover (the Users-level monitor can be denied that HKLM
write) and removes the Intune Sync task when done.
- Both lists ship empty. A site adds entries and installers.
- WinPE choice 3 goes straight to the PPKG menu. Staging, fetch and heal
carry only the generic payload. The webapp's shopfloor sub-menu editor
is gone, and the imaging tiles name the new stages.
- The playbook deploys the empty lists only if missing. It now deploys
the PowerShell 7 MSI the shopfloor unattend installs, which it never
did before.
Blancco site settings move into the webapp (Updates > Blancco releases):
business location, licensing Wi-Fi SSID and password. They are rendered
into the served preferences.xml and applied to every staged release, and
are seeded from site-vars (site_name, blancco_wifi_ssid,
blancco_wifi_password) only while none exist. The repo XML carries no
site values; the plaintext Wi-Fi password is gone from it.
New site_name and site_timezone settings: report and evidence-pack site
name, server clock and webapp time zone. No more West Jefferson defaults
in webapp/config.py or the dashboard title. Sync-BPRT.ps1 gets the
server address filled in at download instead of WJ's GE address.
USB on Windows:
- scripts/Build-PxeUsb.ps1 runs the same checks as build-usb.sh. It
writes one FAT32 CIDATA partition (ISO files plus patched grub.cfg plus
payload) with diskpart and reads every file back by SHA-256.
- Tested with Windows PowerShell 5.1 in the win11 VM, and the layout
installs and first-boots in the pxetest VM.
- scripts/stage-usb-share.sh stages the build folder on a share.
- site-content/ is optional for both builders.
KB docs/kb/How_To_Deploy_PXE_Server_New_Site.html: new-site deployment,
Windows only, with a site-vars.yml guide.
Checks: webapp tests pass (5 suites); the unattend lint and playbook
syntax checks pass; every .ps1 parses; there are no WJ hosts, IPs, names
or PC types in playbook/, webapp/, scripts/ or autoinstall/.
TWO SCRIPTS, DIFFERENT AUDIENCES
playbook/scripts/preflight.ps1 runs at the bay, called by startnet once the
media is mapped. It checks the four things that come straight out of PESetup's
own behaviour:
secure boot GatherDataSelection fails outright when SecurebootEnabled != 1
disk >= 120GB MinRequiredSpaceWithoutCompression is 128849018880
driver match reimplements GetDriverByModel - family filter, untrimmed
comma-separated substring tokens, first match wins - and checks
the pack is actually on the media
media age media expires 30 days after build; Media.tag's timestamp is the
local proxy
The driver check is the one that earns it. A miss is only a WARNING to PESetup,
so the bay images with no NIC, DNS fails at first boot, and enrollment cannot
reach the CDN - a symptom three steps removed from the cause. Advisory by
design: it reports and pauses on a blocker, the tech decides. Lives on the
enrollment share so it can be fixed without rebuilding boot.wim.
scripts/preflight.py runs on the server before a build day and aggregates
everything already built - driver catalogue lint, unattend lint, per-PCTYPE
media view verify - plus a new advisory firmware-coverage check that lists
catalogued models with no BIOS models.txt entry. That last one is how the
OptiPlex 7020 family sat uncovered: 127 catalogued models, 58 covered today.
First run: driver catalogues clean, all three unattends clean, firmware coverage
advisory only. PREFLIGHT PASSED.
Verified: both scripts parse clean (PowerShell parser / python), startnet parens
balance, every goto resolves, 915 CRLF lines with no bare LF. Deployed -
boot.wim md5 99fd3132, preflight.ps1 on the share.