Three fixes so DODA actually deploys on the four bays that need it:
- cmm-bay-config.csv: doda=yes for CMM4, CMM10, CMM11, CMM12 (was no on all
bays). Drives doda.txt -> startnet pc-subtype.txt=doda -> the cmm-doda path.
- cmm-manifest.json: DODA entry PCTypes "cmm-doda" -> "gea-shopfloor-cmm-doda".
The old value never matched: Test-PCTypeMatches builds the PC identity set as
{gea-shopfloor-cmm, gea-shopfloor-cmm-doda, CMM} (the alias of the cmm type is
bare CMM, no subtype variant), so "cmm-doda" was in no set and the entry was
silently skipped. Must be the exact Type-SubType string.
- Install-DODA.ps1: grant Users + Authenticated Users Full on C:\Apps\DODA\
PreProcess (icacls, SIDs, OI/CI inherit), applied every run. MergeFiles.exe
writes there as the locked-down operator; without it the merge step fails.
Not yet pushed to the SFLD/enrollment share (server unreachable at commit time).
Not smoke-tested - no pwsh available here; logic-traced only.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
- 09-Setup-CMM.ps1: Step 2.5 ACL list targeted C:\Program Files\DODA (a path
that never exists), so the BUILTIN\Users write grant on DODA was silently
skipped. Corrected to C:\Apps\DODA, where Install-DODA.ps1 actually extracts.
- Install-DODA.ps1: create C:\Apps\DODA\PreProcess after extract. The DODA
zip unpacks flat without it; MergeFiles.exe expects it and crashed with
DirectoryNotFoundException (MergeFiles.GetDoDAFolder) when absent.
- docs/cyberark-cmm-doda-policy.md: EPM admin reference for elevating the CMM
report toolchain. CyberArk EPM elevation is per-process and not inherited, so
the external tools PC-DMIS spawns (MergeFiles/PCDToIGES/RotateProbeVector/
DovetailAnalysis) run un-elevated and fail. Doc gives the Application Group
(by SHA-256), the Elevate policy, scope, verify steps, and the
CREATE_PDF_FROM_RTF.BAS rework that drops Word/Reader from the elevation set.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Add bay picker (same arrow-key pattern as waxtrace) that maps CMM1-12
to a PC-DMIS version (2016/2019/2026) and DODA flag via cmm-bay-config.csv.
startnet.cmd: replace Standard/DODA submenu with bay picker. Writes
CMMID (e.g. CMM4) to machine-number.txt so the existing
TargetMachineNumbers filter on the SFLD share manifest gates per-bay
entries with no lib changes.
09-Setup-CMM: reads resolved version.txt and filters cmm-manifest.json
by _CmmVersion tag at imaging time so only the matched PC-DMIS version
installs.
cmm-manifest.json: add PC-DMIS 2026.1 entry (patched MSI, product code
{81BACE1B-FB08-4DCF-8100-79911AD3EC1E}) and DODA entry (flat zip extract
to C:\Apps\DODA\). Existing 2016/2019 entries tagged with _CmmVersion.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>