Commit Graph

65 Commits

Author SHA1 Message Date
cproudlock
1a5feefb01 CMM: grant Users Modify on PC-DMIS install dirs for non-admin launch
PC-DMIS writes settings, probe configs, and measurement data to its own
Program Files install directory at runtime. Without Modify permission
for BUILTIN\Users, non-admin accounts (ShopFloor) get a UAC elevation
prompt on every launch. The "run as admin once" workaround can't be
automated because PC-DMIS shows a license dialog on first run that
blocks silently.

Fix: grant BUILTIN\Users Modify with inheritance on:
  - C:\Program Files\Hexagon\PC-DMIS 2016.0 64-bit
  - C:\Program Files\Hexagon\PC-DMIS 2019 R2 64-bit
  - C:\ProgramData\Hexagon

Runs as Step 2.5 in 09-Setup-CMM.ps1 after Install-FromManifest
completes. If the exe also has an embedded requireAdministrator manifest
(separate from the file-permission issue), that will need an additional
fix after testing.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-16 10:38:24 -04:00
cproudlock
ac23759486 UDC firewall rules + Acrobat Reader as default PDF viewer
- Pre-create Windows Firewall inbound-allow rules for UDC.exe and
  MTConnect agent.exe before UDC_Setup.exe runs, suppressing the
  interactive "allow through firewall?" dialogs during silent install.

- Set Adobe Acrobat Reader (Acrobat.Document.DC) as the default .pdf
  handler via dism /import-defaultappassociations. Runs in
  03-ShellDefaults.ps1 so the OEMDefaultAssociations.xml is in place
  before ShopFloor's profile is created on first logon. Edge no longer
  claims .pdf on new profiles.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-16 09:18:44 -04:00
cproudlock
85e74e5dd1 UDC settings: pre-stage from server backups, fix arg format, action prompts
Root cause found via decompiling UDC_Setup.exe: it never writes
udc_settings.json from CLI args. Instead it pulls
Settings_Backups\udc_settings_<num>.json from \\tsgwp00525\shared\SPC\UDC
-- which is unreachable at imaging time (no SFLD creds yet). Silent
File.Exists() false, settings never copy, UDC lands on Evendale defaults.

Fix: stage 80 udc_settings_*.json backups under
shopfloor-setup/Standard/udc-backups/ (same tree as ntlars-backups,
xcopy'd to C:\Enrollment\ by existing startnet.cmd). 00-PreInstall
pre-creates C:\ProgramData\UDC\udc_settings.json from the matching
backup BEFORE UDC_Setup.exe runs. Installer's server-side copy silently
fails (unreachable), our pre-staged file survives.

Also:
- preinstall.json UDC InstallArgs corrected: "West Jefferson" -9999
  (quoted spaced site + dash-prefixed number, confirmed via decompile)
- Update-MachineNumber.ps1 UDC.exe relaunch: quoted site + dash number
- Monitor-IntuneProgress: action prompts (Select Device Category after
  Phase 1; Initiate ARTS Lockdown after Phase 5/creds), Display flow
  (3-phase: Registration -> Config -> Lockdown), Phase 6 IME-based
  lockdown detection

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-16 08:44:34 -04:00
cproudlock
db55bd772a sync_intune: professional UI, IME-based lockdown detection
UI overhaul:
  Replaced the 30+ line checkbox-per-sub-item view with a clean
  6-line phase summary styled for GE Aerospace branding. Each phase
  shows one colored status tag: [COMPLETE] green, [IN PROGRESS] cyan,
  [WAITING] gray, [FAILED] red. Action hint for Phase 2 (device
  category assignment) in yellow. QR code + Device ID below.

Phase 6 lockdown detection:
  Replaced DefaultUserName + admin-rename checks (which pass at PPKG
  time, way too early) with Intune Remediation log artifacts:
  - Autologon_Remediation.log: "Autologon set for ShopFloor"
  - Autologon_Detection.log: "matches the expected value: 1"
  These only exist after the Intune Remediation cycle actually fires
  post-enrollment, making Phase 6 a true end-of-chain signal.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-16 07:35:22 -04:00
cproudlock
a4de11814d Force-Lockdown.bat + S: drive logon mapper for ShopFloor end-user
Force-Lockdown.bat (SupportUser desktop):
  Vendor escape hatch when Intune Lockdown push hasn't applied within
  ~30 minutes. Self-elevates via UAC, prompts for typed YES confirmation
  that an ARTS request is in place, then runs sfld_autologon.ps1.

Register-MapSfldShare.ps1 (every PC type):
  The SFLD vendor's 'SFLD - Consume Credentials' scheduled task is
  principal-restricted (admin-only) so it fires for SupportUser logon
  but not for ShopFloor logon -- ShopFloor lands at the desktop with
  no S: drive and no way to reach \\tsgwp00525\shared. Workaround:
  register a parallel 'GE Shopfloor Map S: Drive' AtLogOn task with
  Principal=BUILTIN\Users + RunLevel=Limited that invokes the vendor's
  C:\ProgramData\SFLD\CredentialManager\ConsumeCredentials.ps1 in the
  interactive user's session. Vendor script handles cred-store + net use
  end to end; we just give it a wider trigger principal. Cross-PC-type
  because every shopfloor account needs S:.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-15 18:31:18 -04:00
cproudlock
a334a56f1e WiFi detection: widen regex to catch hyphen-less 'WiFi' + 802.11
Realtek RTL8852BE describes itself as 'Realtek RTL8852BE WiFi 6 802.11ax
PCIe Adapter' -- no hyphen in 'WiFi' -- which the previous regex
'Wi-Fi|Wireless' rejected. migrate-to-wifi.ps1's gate then exited 0
silently and neither wired NIC got disabled, leaving the imaging chain
running over PXE ethernet for the entire PPKG phase.

New regex Wi-?Fi|Wireless|WLAN|802\.11 covers:
  - Wi-Fi (Intel-style with hyphen)
  - WiFi (Realtek-style without hyphen)
  - Wireless (Intel Wireless-AC, Killer Wireless)
  - WLAN (some Realtek/MediaTek variants)
  - 802.11 (vendor-agnostic spec reference, fallback)

Applied in two callers:
- migrate-to-wifi.ps1 (3 occurrences: gate + disable + re-enable on timeout)
- Monitor-IntuneProgress.ps1 (re-enable wired on sync_intune startup)

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-15 18:03:19 -04:00
cproudlock
c23b803dc6 sync_intune: align Phase 3/5/6 columns; ignore benign 'Failed: 0' tails
Cosmetic + accuracy fixes spotted on the live test PC:

- Phase 3 deploy/install lines had a stray double-space after the
  checkbox; Phase 5 'Share creds present in HKLM' and Phase 6
  'Administrator renamed' had wider misalignment. All four lines
  collapsed to single-space-after-checkbox so the column lines up
  with the rest of the table.

- Phase 4 status detector was greping the last 30 lines of each
  Install-*.log for /(?i)\b(ERROR|Failed|exception)\b/. That hit
  benign summary lines like 'Failed: 0' or 'Errors:    0' and
  marked successful runs as failed (Install-VCRedists.ps1 was the
  trigger -- 8/8 'Already installed - skipping' but the summary
  contained 'Failed: 0' and Phase 4 said FAILED). Tightened the
  regex to also exclude /\b(ERROR|Failed|Failures|Errors|Exceptions?)\s*[:=]\s*0\b/
  so the keyword has to be next to a non-zero value (or the
  vocabulary 'Exit code 1603 - FAILED' style still trips correctly).

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-15 17:53:15 -04:00
cproudlock
2db35c2976 UDC: correct CLI arg signature to compact site + dash-prefixed machine#
UDC_Setup.exe and UDC.exe expect:
  UDC_Setup.exe WestJefferson -7605

Not the spaced-quoted positional pair we'd been passing:
  UDC_Setup.exe "West Jefferson" 7605

The wrong format meant UDC ignored both args, fell back to defaults
(Site=Evendale, MachineNumber=blank). Combined with the kill-after-detect
window, neither value got persisted to udc_settings.json regardless of
whether UDC.exe was given time to write.

Changes:
- preinstall.json: UDC InstallArgs now "WestJefferson -9999"
- 00-PreInstall-MachineApps.ps1: site override now matches/replaces
  the compact 'WestJefferson' token (not 'West Jefferson') and uses
  siteNameCompact from site-config; targetNum extraction regex updated
  to '-(\d+)$' for the new dash-prefix format
- Update-MachineNumber.ps1: UDC.exe relaunch now passes positional
  compact-site + dash-prefixed number instead of -site/-machine flags

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-15 17:47:57 -04:00
cproudlock
14d103a248 run-enrollment: switch provtool /source from BPRT to PSCmdlet
BPRT was stopping after the first RestartRequired=true command (DotNet35).
Test image captured 2026-04-15 showed 3 of 21 PPKG commands ran (PPKG
Version Check, Lock Screen, DotNet35) before provtool exited 0 leaving
Office / Chrome / Tanium / Activate-Windows / Enable-DeviceLockdown /
Hide-SupportUser / 12 more scripts unexecuted. Symptom: criticalChecks
said EntraID NOT joined (wrong -- it was), sessions.json showed a
'LogonIdleTask' session perpetually 'Not started', and the resulting PC
was missing most of its fleet software.

BPRT is the OOBE runtime source -- it expects the OOBE engine to own the
post-DotNet35 reboot + resume. In our post-autounattend context there is
no OOBE engine, so restart-required commands stall the pipeline. PSCmdlet
is the source Install-ProvisioningPackage uses internally and has the
correct resume semantics for post-OOBE application.

The original motivation for BPRT (avoiding the 180s PowerShell timeout)
does not apply because we invoke provtool.exe directly, not via the
Install-ProvisioningPackage cmdlet.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-15 17:07:12 -04:00
cproudlock
8528a1bcae Install-FromManifest: add FileVersion detection for version-pinned upgrades
File-existence detection on NTLARS.exe couldn't tell eDNC 6.4.3 from 6.4.4
(both installers leave the same binary in place), so the enforcer skipped
upgrades. FileVersion compares the vendor-stamped FileVersion field on a
named binary against the manifest's DetectionValue with exact-string match.

Added to all three lib copies (common, Standard, CMM). Standard manifest
template flipped to FileVersion against DncMain.exe -- the eDNC main
binary is more reliably version-stamped than the bundled NTLARS sub-tool.

Update workflow now: drop the new vendor MSI on the SFLD share, bump
Installer + DetectionValue in machineapps-manifest.json, next user logon
runs Machine-Enforce which detects mismatch and installs.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-15 16:15:32 -04:00
cproudlock
a6648c5a40 sync_intune: full lifecycle gate, lockdown phase, creds verification
Add Phase 6 (Lockdown) and tighten Phase 5 so the 5-min Intune sync loop
doesn't declare success until the device is genuinely operator-ready.

- Phase 6 watches two HKLM-level signals confirmed in the 2026-04-15
  pre/post lockdown state diff: Winlogon\DefaultUserName flipped to
  'ShopFloor', and local Administrator renamed to 'SFLDAdmin'. Both land
  via MDM PolicyCSP after DSCInstall.log finishes.

- Phase 5 was just checking that the Consume Credentials scheduled task
  existed; that only proves DSC scheduled it. Now also verifies creds
  actually landed under HKLM:\SOFTWARE\GE\SFLD\Credentials\* with
  TargetHost+Username+Password populated -- which is what Machine/Acrobat/
  CMM-Enforce actually consume.

- Final completion gate: DscInstallComplete && CredsPopulated &&
  LockdownComplete (was just DscInstallComplete). Display PCs unchanged --
  they exit early via the no-DSC Phase 1 path.

- Invoke-SetupComplete now issues shutdown /r /t 10 in AsTask mode after
  writing the sync-complete marker and running the Configure-PC machine#
  prompt. Next boot triggers ShopFloor autologon, which materializes the
  ShopFloor profile from C:\Users\Default (where 03-ShellDefaults already
  baked in TaskbarAl=0, etc.).

- Phase 1->2 gap (waiting for tech to assign device category in Intune
  portal) now shows an explicit ACTION hint instead of empty checkboxes.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-15 16:01:52 -04:00
cproudlock
6db170bf54 Shell defaults + eDNC reg restore from machine-number backups
- 03-ShellDefaults.ps1: Default-User TaskbarAl=0 (left), HKLM policies to
  hide Start Recommended section, kill Bing web search + suggestions,
  disable Cortana. LTSC-honoured; runs fleet-wide via baseline loop.

- ntlars-backups/: 147 per-machine eDNC registry backups renamed to
  flat <MachineNumber>.reg scheme. Historical off-by-one entries from
  the original dump rewritten to match CSV-target MachineNo.

- Standard/03-RestoreEDncConfig.ps1: at imaging time, if tech typed a
  real machine number at PXE (not 9999), import <num>.reg from the local
  staged copy. Restores eFocas IP, PPDCS serial, Hssb relays -- not just
  the bare MachineNo. Skipped on Timeclock / 9999 / missing backup.

- Update-MachineNumber.ps1: when tech later sets a real number from 9999,
  pull <num>.reg from tsgwp00525 SFLD share (ntlarsBackupSharePath in
  site-config) and reg-import it before writing the new MachineNo.

- Restore-EDncReg.ps1: shared helper (Mount-SFLDShare + Import-EDncRegBackup)
  used by both callers.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-15 15:42:21 -04:00
cproudlock
67845372b2 Harvest provtool diagnostics, enable ETW channel, skip Timeclock machine#
run-enrollment.ps1:
- Enable Provisioning-Diagnostics-Provider/Admin event log before invoking
  provtool (was disabled by default; no diagnostics survived early runs).
- After provtool returns, copy C:\ProgramData\Microsoft\Provisioning\*
  into C:\Logs\PPKG\ and snapshot HKLM\...\Sessions\* as
  provisioning-sessions.json, plus export the Admin event channel to
  Provisioning-Diagnostics-Admin.evtx. Gives us reviewable state
  without relying on provtool's failure-only diagnostic bundle.
- provtool arg order is positional path + /quiet + /source BPRT (verified
  against ProvEventLog from the PS cmdlet internal call).

startnet.cmd / startnet-template.cmd:
- Standard-Timeclock sub-type skips the machine-number prompt. Timeclock
  PCs do not use a machine number so forcing a prompt wasted tech time
  and left MACHINENUM at the 9999 default anyway. Machine sub-type is
  unaffected.
2026-04-15 14:22:43 -04:00
cproudlock
cc9aad0ea1 Install-FromManifest: add Hash detection for content-versioned files
Needed for eMxInfo.txt (site-specific eDNC config). The file has no
DisplayVersion in the registry and no canonical MSI; we ship it as a
standalone secret on the SFLD share and key drift correction off its
SHA256. When the yearly replacement drops, bump the hash in
machineapps-manifest.json and every Standard-Machine PC catches up on
next logon.

Patched Install-FromManifest in all three copies (CMM, common, Standard)
for consistency. Also adds the eMxInfo.txt entry to the Standard
machineapps-manifest template and an Install-eMxInfo.cmd template that
copies the file into both 32/64-bit eDNC Program Files paths.
2026-04-15 12:37:35 -04:00
cproudlock
3ef981f19e Add Standard-Machine logon enforcer for UDC/eDNC/NTLARS
Reason: Intune DSC's main-category YAML was pushing these to every main
device, including Timeclocks - DSC has no awareness of our pc-subtype
distinction. After UDC/eDNC/NTLARS are removed from the DSC YAML, ongoing
version drift would no longer be corrected. This enforcer replaces that,
scoped correctly by subtype.

Structure mirrors CMM (CMM-Enforce.ps1) and common (Acrobat-Enforce.ps1):
- Machine-Enforce.ps1: SYSTEM logon task; mounts SFLD share with HKLM-
  backed creds; hands off to Install-FromManifest.
- machineapps-manifest.template.json: repo reference; authoritative copy
  lives on the share at \\tsgwp00525.wjs.geaerospace.net\shared\dt\
  shopfloor\main\machineapps\machineapps-manifest.json.
- Register-MachineEnforce.ps1: idempotent setup; stages scripts to
  C:\Program Files\GE\MachineApps and registers the task.
- lib/Install-FromManifest.ps1: copy of the common/ version (already has
  Type=CMD support).

Sub-type gating belt-and-suspenders:
- Run-ShopfloorSetup.ps1 only calls Register-MachineEnforce when
  $pcType -eq "Standard" -and $pcSubType -eq "Machine".
- Machine-Enforce.ps1 itself re-reads pc-subtype.txt and exits early if
  not "Machine", so a mistakenly-deployed copy no-ops.

site-config.json:
- Added "machineappsSharePath" to Standard-Machine pcProfile.

Drive letter U: to stay clear of CMM (S:) and Acrobat (T:) enforcers
that may run concurrently at logon.

Update workflow:
  drop new UDC/eDNC/NTLARS installer on the SFLD share,
  bump DetectionValue in machineapps-manifest.json,
  every Machine PC catches up on next user logon.
2026-04-15 12:16:17 -04:00
cproudlock
8848fca88a Add Acrobat Reader logon enforcer (cross-PC-type), provtool.exe arg fix
Acrobat Reader enforcement:
- playbook/shopfloor-setup/common/ is the cross-PC-type staging dir. Mirrors
  CMM/ structure (enforce script + its Install-FromManifest copy + manifest
  template + register script).
- Acrobat-Enforce.ps1 runs as SYSTEM on every logon, reads
  acrobatSharePath from site-config.common, mounts the SFLD share with
  the same HKLM-backed credential lookup CMM-Enforce uses, hands the
  acrobat-manifest.json from the share to Install-FromManifest.
- Install-FromManifest extended with Type=CMD so it can invoke vendor-
  supplied .cmd wrappers (Install-AcroReader.cmd does a two-step MSI+MSP
  install that does not fit MSI/EXE types cleanly). cmd.exe /c wraps it
  because UseShellExecute=false cannot launch .cmd directly.
- Register-AcrobatEnforce.ps1 stages scripts to C:\Program Files\GE\Acrobat
  and registers "GE Acrobat Enforce" scheduled task. Called from
  Run-ShopfloorSetup.ps1 right before the enrollment (PPKG) step so it
  applies to every PC type, not just CMM.
- acrobat-manifest.template.json is the repo reference; the authoritative
  copy lives on the SFLD share at
  \\tsgwp00525.wjs.geaerospace.net\shared\dt\shopfloor\common\acrobat\
  Bumping Acrobat updates = drop new MSP on share, bump DetectionValue in
  manifest; enforcer catches every PC on next logon.
- site-config.json: add "common": { "acrobatSharePath": ... }. Uses a
  new top-level block rather than a PC-type-specific one since Acrobat
  applies everywhere.

Initial install still happens via the preinstall flow
(Install-AcroReader.cmd during WinPE). The enforcer is the ongoing-
updates side; on a freshly-imaged PC detection passes and it no-ops.

Also in this commit:
- run-enrollment.ps1: provtool.exe argument syntax fix. First test
  returned 0x80004005 E_FAIL in 1s because /ppkg: and /log: are not
  valid provtool flags; the cmdlet's internal call used positional
  path + /quiet + /source. Switched to that syntax.
2026-04-15 09:24:13 -04:00
cproudlock
5a9c3db7af run-enrollment.ps1: invoke provtool.exe directly, skip PowerShell cmdlet timeout
Observed today on E8FHGDB4: Install-ProvisioningPackage timed out after
the PowerShell cmdlet's hardcoded 180s limit on a 7.6 GB GCCH v4.10
PPKG. The catch-block fell through to Add-ProvisioningPackage, which
returned "success" but the PPKG diagnostic bundle showed the child
provtool.exe was called with empty packagePathsToAdd (session created,
State=Not started, RebootCount=0). The PC was named, OOBE-completed,
and BPRT apps ran, but the bulk enrollment never applied - PC was not
Entra-joined.

Microsoft Docs GitHub issue 502 confirms the 180s cmdlet timeout is
hardcoded with no configuration option. Quest KB 4376269 suggests
rebuilding the PPKG with the latest Windows Configuration Designer,
but that is upstream and not under our control per PPKG.

Switch to Start-Process -FilePath provtool.exe -Wait. The wait is on
the actual child process, no caller-side timeout. provtool.exe is
what the cmdlet was invoking anyway; we just bypass the wrapper that
imposes the limit.

Sources:
  https://support.quest.com/on-demand-migration/kb/4376269
  https://github.com/MicrosoftDocs/windows-powershell-docs/issues/502
  https://learn.microsoft.com/en-us/windows/configuration/provisioning-packages/provisioning-apply-package
2026-04-15 08:35:35 -04:00
cproudlock
d6776f7c7f Reorganize repo, enrollment share taxonomy, Blancco USB-build fixes, v4.10 PPKGs
Workstation reorganization:
- All build/deploy/helper scripts moved into scripts/ (paths updated to use
  REPO_ROOT instead of SCRIPT_DIR so they resolve sibling dirs from the new
  depth)
- New config/ directory placeholder for site-specific overrides
- Removed stale: mok-keys/, test-vm.sh, test-lab.sh, setup-guide-original.txt,
  unattend/ (duplicate of moved playbook/FlatUnattendW10.xml)
- README.md and SETUP.md structure listings updated, dead "Testing with KVM"
  section removed
- .claude/ gitignored

Enrollment share internal taxonomy (forward-looking; existing servers
unaffected since they keep their current boot.wim with flat paths):
- Single SMB share kept (WinPE only mounts one Y: drive), but content now
  organised into ppkgs/, scripts/, config/, shopfloor-setup/, pre-install/{bios,
  installers}, installers-post/cmm/, blancco/, logs/
- README.md deployed to share root explaining each subdir
- New playbook tasks deploy site-config.json + wait-for-internet.ps1 +
  migrate-to-wifi.ps1 explicitly (were ad-hoc on legacy servers)
- BIOS subdir moved into pre-install/bios/, preinstall/ renamed to pre-install/
- startnet.cmd + startnet-template.cmd updated with new Y:\subdir\ paths
- Bumped GCCH PPKG references v4.9 -> v4.10

Blancco USB-build fixes (so next fresh USB install boots Blancco end-to-end
without the manual fixup we did against GOLD):
- grub-blancco.cfg: kernel/initrd switched HTTP -> TFTP (GRUB's HTTP module
  times out on multi-MB files); added modprobe.blacklist=iwlwifi,iwlmvm,btusb
  (WiFi drivers hang udev on Intel business PCs)
- grubx64.efi rebuilt from updated cfg
- Playbook task added to create /srv/tftp/blancco/ symlinks pointing at the
  HTTP-served binaries

run-enrollment.ps1: OOBEComplete is now set AFTER PPKG install (Win11 22H2+
hangs indefinitely if OOBEComplete is set before the bulk-enrollment PPKG runs).

Also includes deploy-bios.sh / pull-bios.sh / busybox-static / models.txt
that were sitting untracked at the repo root.
2026-04-14 16:01:02 -04:00
cproudlock
855af7312b Sub-type aware preinstall, USB drivers/PPKGs, Lab OpenText
- PreInstall runner reads pc-subtype.txt and matches PCTypes against
  both base type (Standard) and composite key (Standard-Machine).
- UDC scoped to Standard-Machine only. eDNC and MachineNumberACLs
  skip on Standard-Timeclock sub-type.
- Lab added to OpenText PCTypes.
- build-usb.sh copies enrollment/ (PPKGs) and drivers-staging/ (Dell
  driver packs) onto USB for self-contained deployment.
- Playbook deploys PPKGs and drivers from USB to PXE server shares.
- Gitignore enrollment/, drivers-staging/, *.ppkg (large binaries).

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-13 15:00:23 -04:00
cproudlock
855d501fc2 Fix Display sync loop, PPKG deployment, dnsmasq cron, dpkg configure
- Monitor-IntuneProgress: Display PCs skip DSC phases entirely (no SAS
  token, no DSCInstall.log), complete after Phase 1 identity. Renderer
  hides Phase 2-5 for Display type.
- Playbook: deploy PPKG files and run-enrollment.ps1 from USB to
  enrollment share. Bump dnsmasq restart cron from 15s to 30s.
- build-usb.sh: copy enrollment/ directory (PPKGs) onto USB if present.
- user-data: add dpkg --configure -a after offline .deb install to fix
  packages left in unconfigured state (cron, systemd-timesyncd).

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-13 14:27:21 -04:00
cproudlock
743bc91996 Shopfloor Display: move kiosk app install to preinstall system
Install-KioskApp.cmd wrapper reads display-type.txt and runs the
matching Inno Setup installer (Lobby or Dashboard). Replaces the
standalone 09-Setup-Display.ps1 for uniform app install pipeline.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-13 11:38:59 -04:00
cproudlock
f3211dfd29 CMM test iteration: desktop shortcuts, rename to 09-Setup-*, defer NIC re-enable
Rolls up everything from the CMM imaging test iteration tonight. No
single concern - several small, related polish items on the option-3
patched-MSI pipeline and the shopfloor-setup / sync_intune handoff.

- Rename all type-specific "01-Setup-<Type>.ps1" scripts to
  "09-Setup-<Type>.ps1" across CMM, Display, Genspect, Keyence, Lab,
  and WaxAndTrace. The "01-" prefix implied the script runs first in
  the overall sequence when it actually runs between baseline (00, 04)
  and finalization (06, 07). Logs now read "Running CMM setup:
  09-Setup-CMM.ps1" which matches the real position. Standard/
  01-eDNC.ps1 + 02-MachineNumberACLs.ps1 left alone - those digits
  represent real within-type ordering.
- playbook/shopfloor-setup/site-config.json CMM profile updates:
  - startupItems = [] (empty). Previously had WJ Shopfloor auto-launch
    which the user does not want on CMM workstations. Now relies on
    the Get-ProfileValue empty-array fix to not fall through to site
    defaults.
  - desktopApps + taskbarPins gain entries for PC-DMIS 2016, PC-DMIS
    2019 R2, CLM Admin, and goCMM so 06-OrganizeDesktop Phase 2
    materializes them into C:\\Users\\Public\\Desktop\\Shopfloor Tools\\
    and 07-TaskbarLayout pins them. goCMM is under C:\\Program Files
    (x86)\\General Electric\\goCMM\\ (GE product, not Hexagon).
- playbook/shopfloor-setup/Run-ShopfloorSetup.ps1: remove the blocking
  "UNPLUG ethernet cable, press any key" prompt + the interactive
  wired-NIC re-enable. The whole prompt block was a hard blocker on
  the imaging chain that required a human to walk to each PC.
- playbook/shopfloor-setup/Shopfloor/lib/Monitor-IntuneProgress.ps1:
  re-enable wired NICs unconditionally at the top of the transcript.
  This is the new home for the re-enable that used to live behind the
  prompt in Run-ShopfloorSetup. By the time sync_intune fires (after
  PPKG reboot + auto-login + Stage-Dispatcher), the tech has had
  minutes of wall-clock time to physically rewire from PXE to
  production without us blocking on a keypress. Tower case is a
  no-op because migrate-to-wifi.ps1 already left wired enabled.
- Internal comment updates in 09-Setup-CMM.ps1, cmm-manifest.json,
  Install-FromManifest.ps1, and startnet.cmd (+ startnet-template)
  to reflect the new filename.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-11 21:03:09 -04:00
cproudlock
b88e4d3272 CMM: patched-MSI install chain for PC-DMIS 2016 + 2019 R2
PC-DMIS refuses to install without a valid license in /qn mode; its
BA / MSI custom actions ProcessLicensingFromBundle (which spins for
~13 minutes trying to activate against licensing.wilcoxassoc.com)
and IsLicenseDateValid (which errors 1603 when no license file is
present) are the gate. Bypassed by dark-extracting the chained MSIs
from each Burn bundle and pre-patching both custom actions'
InstallExecuteSequence.Condition columns to '0' via Windows
Installer COM SQL UPDATE. The patched MSIs install cleanly with no
license, PCDLRN.exe loads at runtime, hits its own runtime license
check, and shows the normal "no license" dialog. Tech activates via
clmadmin.exe post-imaging and PC-DMIS launches normally.

- playbook/preinstall/preinstall.json: adds VC++ 2010 x64 and VC++
  2012 x64 redistributable entries scoped to all PC types. PC-DMIS
  links msvcr100.dll / mfc100u.dll (VS 2010) and msvcr110.dll /
  mfc110u.dll (VS 2012); without these the exe gets DLL_NOT_FOUND
  (0xC0000135) at launch. Win11 ships VC++ 2022 (covers 2015+) but
  not 2010/2012, so we ship these from the dark-extracted bundle
  payloads. Small (~13 MB combined), inert on PCs that don't need
  them, so the filter is "*".
- playbook/shopfloor-setup/CMM/cmm-manifest.json: version 2.0.
  Drops the bundle EXEs, installs patched MSIs directly with
  properly quoted INSTALLFOLDER / APPLICATIONFOLDER paths (the
  earlier "hangs" were caused by Start-Process splitting unquoted
  paths on spaces, not actual msiexec hangs). Skips the chained
  CLM Tools 1.5/1.7 MSIs - CLM 1.8.73 standalone provides the same
  interfaces and PC-DMIS MSIs have no LaunchCondition requiring
  Tools 1.5 / 1.7 specifically. Keeps Protect Viewer from the 2019
  R2 bundle as a separate entry. CLM 1.8 and goCMM bundles run
  unpatched (no install-time license check).
- playbook/sync-cmm.sh: now also includes *.msi files in the
  upload set, not just *.exe.

Known caveats: patched MSIs have HashMismatch signatures (expected
- Windows Installer accepts them in /qn mode on locally-cached
  machines). Every Hexagon bundle version bump requires re-dark-
extracting and re-patching. Unsupported by Hexagon; do not call
them for install-related issues without reverting to the original
bundles first.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-11 16:52:54 -04:00
cproudlock
ee7d3bad66 Shopfloor imaging: CMM type, Configure-PC override fix, serial drivers
- CMM imaging pipeline: WinPE-staged bootstrap + on-logon enforcer
  against tsgwp00525 share, manifest-driven installer runner shared via
  Install-FromManifest.ps1. Installs PC-DMIS 2016/2019 R2, CLM 1.8,
  goCMM; enables .NET 3.5 prereq; registers GE CMM Enforce logon task
  for ongoing version enforcement.
- Shopfloor serial drivers: StarTech PCIe serial + Prolific PL2303
  USB-to-serial via Install-Drivers.cmd wrapper calling pnputil
  /add-driver /subdirs /install. Scoped to Standard PCs.
- OpenText extended to CMM/Keyence/Genspect/WaxAndTrace via
  preinstall.json PCTypes; Defect Tracker added to CMM profile
  desktopApps + taskbarPins.
- Configure-PC startup-item toggle now persists across the logon
  sweep via C:\\ProgramData\\GE\\Shopfloor\\startup-overrides.json;
  06-OrganizeDesktop Phase 3 respects suppressed items.
- Get-ProfileValue helper added to Shopfloor/lib/Get-PCProfile.ps1;
  distinguishes explicit empty array from missing key (fixes Lab
  getting Plant Apps in startup because empty array was falsy).
- 06-OrganizeDesktop gains transcript logging at C:\\Logs\\SFLD\\
  06-OrganizeDesktop.log and now deletes the stale Shopfloor Intune
  Sync task when C:\\Enrollment\\sync-complete.txt is present (task
  was registered with Limited principal and couldn't self-unregister).
- startnet.cmd CMM xcopy block (gated on pc-type=CMM) stages the
  bundle to W:\\CMM-Install during WinPE.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-11 12:58:47 -04:00
cproudlock
bc123c1066 Machine number input at PXE menu for Standard PCs
Adds a machine number prompt to startnet.cmd after the Standard sub-type
selection. Tech enters the number during the PXE boot process. Defaults
to 9999 if Enter is pressed (existing placeholder behavior).

Written to C:\Enrollment\machine-number.txt alongside pc-type.txt.

Consumers:
  00-PreInstall-MachineApps.ps1 - replaces 9999 in UDC InstallArgs with
    the entered number, so UDC installs with the correct machine number
    from the start (no post-setup Set-MachineNumber needed).
  01-eDNC.ps1 - writes the machine number to the DNC\General\MachineNo
    registry value during eDNC install.
  Configure-PC.ps1 - existing $needsMachineNumber check already skips
    the prompt when UDC/eDNC aren't at 9999, so no change needed.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-11 08:50:02 -04:00
cproudlock
3d5814cd7c Use marker file instead of task unregister for sync completion
BUILTIN\Users (Limited RunLevel) can't delete scheduled tasks, so
Unregister-ScheduledTask failed silently and the sync task kept firing
at every logon even after completion.

Fix: write C:\Enrollment\sync-complete.txt on completion. At script
startup in -AsTask mode, check for the marker and exit immediately if
found. The task stays in Task Scheduler but does nothing -- fires at
logon, sees marker, exits in under a second. No visible window.

Manual sync_intune.bat runs (no -AsTask) ignore the marker and always
show the full status display for inventory QR code purposes.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-10 15:09:11 -04:00
cproudlock
6d887346b6 Add Chrome homepage + startup tabs mirroring Edge config
Chrome (installed by PPKG) now gets the same profile-driven homepage
and startup tabs as Edge. Uses HKLM:\SOFTWARE\Policies\Google\Chrome
with the same policy keys (RestoreOnStartup, RestoreOnStartupURLs,
HomepageLocation, HomepageIsNewTabPage, ShowHomeButton).

Reuses the $startupTabs and $homepageUrl already resolved for Edge
from the PC profile, so both browsers show identical tabs. Skips
cleanly if Chrome isn't installed.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-10 14:56:48 -04:00
cproudlock
07ebe819bd Auto-apply startup items from profile, Configure-PC -MachineNumberOnly
Three changes to eliminate the redundant startup-item picker during
the imaging chain:

06-OrganizeDesktop.ps1 - new Phase 3: auto-apply startup items
  Reads pcProfile.startupItems (or site-wide default) and creates
  .lnk files in AllUsers Startup folder. Supports exe, existing, and
  url types (same as Configure-PC). Idempotent - skips items that
  already exist so manual changes aren't overwritten. Runs during
  shopfloor setup finalization, so the tech doesn't need to select
  startup items again.

Configure-PC.ps1 - new -MachineNumberOnly switch
  When set, skips the entire startup-items section and only shows the
  machine number prompt (if UDC/eDNC at 9999). Used by sync_intune
  -AsTask after completion. Full startup picker still available when
  the tech opens Configure-PC.bat manually from the desktop.

Monitor-IntuneProgress.ps1 - simplified -AsTask completion
  After post-reboot DSC complete: unregisters task, launches
  Configure-PC -MachineNumberOnly, exits. Tech uses sync_intune.bat
  on the desktop to see QR code for inventory purposes.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-10 14:54:31 -04:00
cproudlock
15f67063bd Refresh QR code after AAD join detected
The QR code text was built once at script startup. If the device wasn't
AAD-joined yet, it showed "Device not yet Azure AD joined" forever -
even after Phase 1 checks passed. Now regenerates Build-QRCodeText
when Phase1.AzureAdJoined transitions to true.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-10 14:38:15 -04:00
cproudlock
b69d68f7b5 Register sync task BEFORE enrollment (PPKG reboot kills run-enrollment)
Install-ProvisioningPackage triggers an immediate reboot that kills
run-enrollment.ps1 before it can register the sync_intune task or do
any post-install work. BPRT app installs happen on the NEXT boot, not
before the reboot.

Fix: move sync task registration into Run-ShopfloorSetup.ps1, executed
BEFORE calling run-enrollment.ps1. The task is safely registered while
we still have control. Then enrollment installs the PPKG and lets it
reboot. After reboot, BPRT finishes in background, sync task fires at
logon, monitors Intune enrollment (which is independent of BPRT).

Run-ShopfloorSetup.ps1:
  - Registers "Shopfloor Intune Sync" @logon task after desktop tool
    copies but BEFORE enrollment
  - Flushes transcript before calling enrollment (since PPKG reboot
    will kill us, ensures log is complete)
  - Enrollment is the absolute last call

run-enrollment.ps1:
  - Stripped to essentials: find PPKG, rename computer, set OOBE,
    Install-ProvisioningPackage
  - No BPRT polling (irrelevant - happens after reboot)
  - No task registration (already done by caller)
  - No shutdown call (PPKG handles it)

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-10 14:15:45 -04:00
cproudlock
db3f126fb3 Bump AutoLogonCount from 2 to 4 for reboot margin
The imaging chain needs exactly 2 autologons after the first boot
(sync_intune pre-reboot + post-reboot). Setting to 4 adds 2 extra
reboots of margin for unexpected restarts from Windows Update, PPKG
file operations, or script crashes.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-10 13:41:23 -04:00
cproudlock
c06310f5bd Replace all Unicode characters with ASCII in playbook scripts
Em dashes (U+2014) and arrows (U+2192) break PowerShell 5.1 on
Windows when the file has no UTF-8 BOM -- byte 0x94 gets read as
a right double quote in Windows-1252, silently closing strings
mid-parse. This caused run-enrollment.ps1 to fail on PXE-imaged
machines with "string is missing the terminator" at line 113.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-10 13:23:11 -04:00
cproudlock
fb5841eb20 run-enrollment: wait for PPKG provisioning before staging chain
Install-ProvisioningPackage is async — it queues the provisioning engine
and returns immediately. The actual BPRT app installs (Chrome, Office,
Tanium, CyberArk, etc.) run in the background. Without waiting, the
PPKG reboot fires while installs are still in progress, leaving apps
partially installed.

Fix: poll for C:\Logs\BPRT\Remove Staging Locations\Log.txt — the last
BPRT step. When that file exists, all provisioning steps have completed.
Polls every 10 seconds for up to 15 minutes (Office install can be slow).
Progress logged every 30 seconds showing which steps have finished.

If the timeout fires (15 min), logs a warning and proceeds — the SYSTEM
logon task from 06-OrganizeDesktop.ps1 provides self-healing on the next
boot for anything that was incomplete.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-10 12:31:36 -04:00
cproudlock
6c76719a47 Logging, PCTypes, edge profiles for all types
Three final optimization batches:

1. Start-Transcript added to 4 scripts that lacked standalone logging:
   04-NetworkAndWinRM.ps1, 05-OfficeShortcuts.ps1, 01-eDNC.ps1,
   02-MachineNumberACLs.ps1. Each writes to C:\Logs\SFLD\<name>.log
   with append mode. Stop-Transcript added before exit points.

2. preinstall.json: Oracle Client PCTypes changed from ["*"] to
   ["Standard", "CMM", "Genspect", "Keyence", "WaxAndTrace", "Display"].
   Lab Workstations don't need Oracle Client (shopfloor data app
   dependency). VC++ redists stay at ["*"] (harmless shared deps).

3. Edge profiles added to all remaining PC types in site-config.json:
   CMM, Genspect, Keyence, WaxAndTrace, Standard-Timeclock all get the
   standard 3-tab setup (Plant Apps + Homepage + Dashboard) with
   homepage = tsgwp00524. Display-Lobby and Display-Dashboard get
   Shopfloor Dashboard as both homepage and single tab.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-10 11:57:22 -04:00
cproudlock
ed3bfc8234 Lab Workstation: profile-aware Edge homepage + startup tabs
Lab profile in site-config.json now has:
  edgeHomepage: http://tsgwp00524.logon.ds.ge.com/
  edgeStartupTabs: WJ Shop Floor Homepage, M365 Webmail, Shopfloor Dashboard

08-EdgeDefaultBrowser.ps1 now resolves edge config from:
  pcProfile.edgeStartupTabs > siteConfig.edgeStartupTabs > hardcoded
  pcProfile.edgeHomepage > first startup tab (existing behavior)

This lets different PC types have different Edge configs:
  Standard-Machine: Plant Apps + Homepage + Dashboard (homepage = Plant Apps)
  Lab: Homepage + Webmail + Dashboard (homepage = tsgwp00524)

Added webmail URL to site-config.json urls section:
  "webmail": "https://outlook.office365.us/mail"

Lab gets no OpenText/UDC/eDNC — already filtered:
  OpenText + UDC: PCTypes = ["Standard"] in preinstall.json
  eDNC: Standard/01-eDNC.ps1 (type-specific, never runs for Lab)
  Office: from PPKG (shared across all shopfloor types)

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-10 11:49:43 -04:00
cproudlock
7c8eb6899d Shared machine-number helper, site-config for OpenText + PreInstall, placeholder type dirs
Three optimization batches from the pipeline audit:

1. Shared Update-MachineNumber.ps1 helper (lib/)
   Extracts duplicated machine-number update logic from Configure-PC.ps1,
   Check-MachineNumber.ps1, and Set-MachineNumber.ps1 into a shared
   dot-sourceable helper at Shopfloor/lib/Update-MachineNumber.ps1.

   Exports:
     Get-CurrentMachineNumber → @{ Udc = $string; Ednc = $string }
     Update-MachineNumber -NewNumber <n> [-Site <s>] → @{ UdcUpdated; EdncUpdated; Errors }

   All three consumers now dot-source the helper instead of duplicating
   ~50 lines each. Set-MachineNumber.ps1 also migrated from inline
   Get-SiteConfig to dot-sourcing Get-PCProfile.ps1 for consistency.

2. Site-config integration for remaining scripts
   Setup-OpenText.ps1: exclude lists (profiles + shortcuts) now read from
     site-config.json opentext section, falling back to West Jefferson
     defaults. Inline Get-SiteConfig since the script runs from
     C:\PreInstall\installers\opentext\ (can't dot-source Get-PCProfile).

   00-PreInstall-MachineApps.ps1: after parsing preinstall.json, scans
     InstallArgs for "West Jefferson" and replaces with site-config
     siteName if different. Inline Get-SiteConfig for same reason.

3. Placeholder type-specific directories
   Created skeleton 01-Setup-*.ps1 scripts for all PC types so the
   directory structure is in place and Run-ShopfloorSetup's type-specific
   loop has something to iterate over:
     Genspect/01-Setup-Genspect.ps1
     Keyence/01-Setup-Keyence.ps1
     WaxAndTrace/01-Setup-WaxAndTrace.ps1
     Lab/01-Setup-Lab.ps1
   Each logs a "no type-specific apps configured yet" banner and exits.
   Fill in app installs when details are finalized; for share-based
   installs, copy the CMM/01-Setup-CMM.ps1 pattern.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-10 11:44:10 -04:00
cproudlock
b236b18fbc CMM: share-based installer framework with SFLD credential lookup
Refactored CMM/01-Setup-CMM.ps1 from local-file installer to network-
share-based pattern. CMM apps live on a file share instead of being
pre-staged locally or pulled from Azure Blob.

Framework:
  1. Reads share path from site-config.json CMM profile (cmmSharePath),
     falls back to West Jefferson default
  2. Scans HKLM:\SOFTWARE\GE\SFLD\Credentials\* for a credential entry
     whose TargetHost matches the share's server name
  3. Mounts the share as S: using net use with the stored creds
  4. (Placeholder) Install apps from the share
  5. Disconnects the share

The Get-SFLDCredential helper function is generic and will be reused by
Genspect/Keyence scripts when their share-based installs are built. It
matches credentials by TargetHost field, supporting exact match and
domain-suffix matching.

App install blocks are commented out as placeholders — uncomment when
PC-DMIS, CLM License, and other Hexagon app details are finalized.

Added cmmSharePath to site-config.json CMM profile.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-10 11:24:22 -04:00
cproudlock
ed803539e0 PC profiles: per-type/sub-type config + Standard Timeclock/Machine menu
Adds a pcProfiles section to site-config.json that lets each PC type (and
optional sub-type) override startupItems, taskbarPins, and desktopApps.
Scripts resolve: pcProfile > site-wide default > hardcoded fallback.

New shared helper: Shopfloor/lib/Get-PCProfile.ps1
  Dot-sourced by consuming scripts. Reads pc-type.txt + pc-subtype.txt,
  builds a profile key (e.g. "Standard-Machine"), and looks it up in
  site-config.json pcProfiles. Exports $siteConfig, $pcType, $pcSubtype,
  $profileKey, $pcProfile for the caller to use.

  Replaces the inline Get-SiteConfig function that was copy-pasted into
  each script. Scripts now do:
    . "$PSScriptRoot\lib\Get-PCProfile.ps1"
  instead of duplicating the loader.

startnet.cmd changes:
  - Added Lab as PC type option (7)
  - Standard now has a sub-type menu: Timeclock / Machine
  - Display sub-type menu also writes PCSUBTYPE for consistency
  - pc-subtype.txt written alongside pc-type.txt when sub-type selected
  - site-config.json copied from enrollment share to W:\Enrollment\

site-config.json v2.0:
  - New pcProfiles section with profiles for:
    Standard-Timeclock, Standard-Machine, CMM, Genspect, Keyence,
    WaxAndTrace, Lab, Display-Lobby, Display-Dashboard
  - CMM/Genspect/Keyence/WaxAndTrace profiles have TODO comments for
    type-specific apps (placeholder with WJ Shopfloor baseline only)
  - Lab/Display profiles have empty startupItems and desktopApps
  - Top-level startupItems/taskbarPins/desktopApps remain as site-wide
    defaults (used when no profile matches)

Updated scripts:
  06-OrganizeDesktop.ps1 - desktopApps from profile > site > hardcoded
  07-TaskbarLayout.ps1   - taskbarPins from profile > site > hardcoded
  08-EdgeDefaultBrowser.ps1 - uses shared profile loader
  Configure-PC.ps1       - startupItems from profile > site > hardcoded

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-10 11:19:51 -04:00
cproudlock
0aaf049942 Extract site-specific values to site-config.json
New site-config.json file at C:\Enrollment\ (staged by startnet.cmd from
the enrollment share) contains all West Jefferson-specific values that were
previously hardcoded across 7 scripts. To deploy at a different GE site,
clone site-config.json and change the values - scripts need zero changes.

Config schema (v1.0):
  siteName / siteNameCompact  - UDC/eDNC site args
  urls{}                      - Edge startup tab fallback URLs
  edgeStartupTabs[]           - ordered tab list with .url file basenames
  opentext{}                  - excluded .hep profiles and .lnk shortcuts
  startupItems[]              - Configure-PC toggle list (exe/existing/url)
  taskbarPins[]               - 07-TaskbarLayout pin order with lnk paths
  desktopApps[]               - 06-OrganizeDesktop Phase 2 app list

Every script uses the same inline Get-SiteConfig helper that reads the
JSON and returns $null if missing/corrupt. All consumers fall back to the
current hardcoded West Jefferson defaults when $siteConfig is null, so
PXE servers without a site-config.json continue working identically.

Scripts updated:
  06-OrganizeDesktop.ps1   - desktopApps array from config
  07-TaskbarLayout.ps1     - pinSpec array from config
  08-EdgeDefaultBrowser.ps1 - startup tab loop from config
  Configure-PC.ps1         - startup items + site name from config
  Check-MachineNumber.ps1  - site name from config
  Set-MachineNumber.ps1    - site name from config
  01-eDNC.ps1              - siteName + siteNameCompact from config
  startnet.cmd             - copies site-config.json from enrollment share

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-10 11:11:35 -04:00
cproudlock
45ff163eea Fix reboot race + dispatcher owns all reboots
Two related fixes from the pipeline audit:

1. Stage-Dispatcher race condition (critical):
   Run-ShopfloorSetup.ps1 called shutdown /r /t 10 and the dispatcher
   had to write the next stage + register RunOnce within that 10-second
   window. If disk I/O was slow, the reboot fired before RunOnce was
   registered, and the chain broke.

   Fix: dispatcher now cancels Run-ShopfloorSetup's pending reboot
   (shutdown /a) immediately after it returns, then advances the stage
   and registers RunOnce with no time pressure, then initiates its own
   shutdown /r /t 5.

2. Dispatcher owns all reboots:
   Run-ShopfloorSetup.ps1 now checks the -FromDispatcher flag at the
   end. When called by the dispatcher, it schedules shutdown /r /t 30
   as a safety net (the dispatcher cancels it immediately). When called
   standalone (manual run or legacy FirstLogonCommands), it reboots
   directly with /t 10 as before.

   This means the dispatcher has full control over the reboot lifecycle:
   cancel -> advance stage -> register RunOnce -> reboot. No racing.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-10 10:58:57 -04:00
cproudlock
3494aa0554 Fix stage gate infinite loop: -FromDispatcher bypass
The stage-file gate in Run-ShopfloorSetup.ps1 would fire even when
called by Stage-Dispatcher.ps1 (because the stage file still contains
"shopfloor-setup"), causing an infinite exit loop.

Fix: Run-ShopfloorSetup now accepts -FromDispatcher switch. The gate
only fires when the switch is absent (i.e. when called by the unattend's
FirstLogonCommands). Stage-Dispatcher passes -FromDispatcher when
invoking Run-ShopfloorSetup, bypassing the gate.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-10 10:20:20 -04:00
cproudlock
12bcc9b549 Stage gate in Run-ShopfloorSetup + sync retrigger 5min
Run-ShopfloorSetup.ps1 now checks for C:\Enrollment\setup-stage.txt at
the very top. If the stage file exists (written by run-enrollment.ps1),
the script exits immediately with "deferring to Stage-Dispatcher.ps1
on next logon". This prevents the unattend's FirstLogonCommands chain
from running Run-ShopfloorSetup in the same session as run-enrollment,
which was bypassing the entire staged reboot chain.

Without this gate:
  FirstLogonCommand #1: run-enrollment.ps1 (sets stage file + RunOnce)
  FirstLogonCommand #2: Run-ShopfloorSetup.ps1 (runs immediately, ignoring stage)
  PPKG reboot fires after both complete
  Next boot: dispatcher has nothing to do (Run-ShopfloorSetup already ran)

With the gate:
  FirstLogonCommand #1: run-enrollment.ps1 (sets stage file + RunOnce)
  FirstLogonCommand #2: Run-ShopfloorSetup.ps1 (sees stage file, exits)
  PPKG reboot fires
  Next boot: RunOnce fires dispatcher, reads "shopfloor-setup", runs
  Run-ShopfloorSetup properly (stage file deleted by gate on re-entry)

Also: Monitor-IntuneProgress.ps1 RetriggerMinutes bumped from 3 to 5.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-10 10:19:34 -04:00
cproudlock
b13e34c05a Imaging chain: Stage-Dispatcher + PPKG reboot + unattended sync_intune
Replaces the single-session "cancel PPKG reboot and cram everything into
one autologon" flow with a staged chain where each reboot advances to the
next step automatically. The technician touches the keyboard 3 times total
(UNPLUG prompt, Y to reboot, Configure-PC selections).

New Stage-Dispatcher.ps1:
  Reads C:\Enrollment\setup-stage.txt and chains through:
    shopfloor-setup -> sync-intune -> configure-pc
  Each stage re-registers HKLM RunOnce so the dispatcher fires again on
  the next logon. Stage file is deleted when the chain completes.
  Transcript logged to C:\Logs\SFLD\stage-dispatcher.log.

  Stage "shopfloor-setup": runs Run-ShopfloorSetup.ps1 (which reboots via
    shutdown /r /t 10). Dispatcher advances stage to sync-intune in the
    ~10 second window before the machine goes down, re-registers RunOnce.

  Stage "sync-intune": launches Monitor-IntuneProgress.ps1 -Unattended.
    Exit 2 (pre-reboot done, user confirmed): dispatcher re-registers
    RunOnce and initiates shutdown /r /t 5. Stage stays at sync-intune so
    the monitor picks up post-reboot state on next boot.
    Exit 0 (post-reboot install complete): dispatcher chains directly to
    Configure-PC.ps1 in the same session, then deletes the stage file.

  Stage "configure-pc": runs Configure-PC.ps1 and deletes the stage file.
    Fallback entry point if the post-reboot chain was interrupted.

Modified run-enrollment.ps1:
  Removed the shutdown /a that canceled the PPKG reboot. Instead writes
  setup-stage.txt = "shopfloor-setup" and registers RunOnce for the
  dispatcher. PPKG reboot fires naturally (handles PendingFileRename
  operations like Zscaler rename and PPKG self-cleanup). Now tracked in
  the git repo at playbook/shopfloor-setup/run-enrollment.ps1.

Modified Monitor-IntuneProgress.ps1:
  New -Unattended switch. When set:
    Invoke-SetupComplete exits 0 without waiting for keypress.
    Invoke-RebootPrompt exits 2 without prompting or rebooting (dispatcher
    handles both). Manual sync_intune.bat usage (no flag) unchanged.
  RetriggerMinutes bumped from 3 to 5 (user request).

Modified startnet.cmd:
  Now also copies Stage-Dispatcher.ps1 from the PXE server to
  W:\Enrollment\Stage-Dispatcher.ps1 alongside run-enrollment.ps1.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-10 09:55:00 -04:00
cproudlock
7c26e10f7e sync_intune: gate reboot prompt on Phase 1+2+3 pre-reboot completion
Don't prompt the user to reboot until the enrollment pipeline has
finished its pre-reboot work. Previously Test-RebootState fired as
soon as DSCDeployment.log showed "completed", even if Phase 1 (Identity)
or Phase 2 (SFLD config) checks were still in progress.

Now the reboot prompt requires ALL of these to be green in the snapshot:
  Phase 1: AzureAdJoined, IntuneEnrolled, EmTaskExists, PoliciesArriving
  Phase 2: SfldRoot, FunctionOk, SasTokenOk
  Phase 3: DeployLogExists, DeployComplete

This prevents the edge case where DSCDeployment.log completes but the
user reboots before Intune policies have fully landed, which could leave
the post-reboot DSC install phase without the SAS token or function
assignment it needs.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-10 09:31:11 -04:00
cproudlock
e17b3a521d Fix 5 bugs from shopfloor-setup transcript review
1. UDC JSON ACL: set on directory C:\ProgramData\UDC\ with
   ContainerInherit+ObjectInherit instead of the file. UDC_Setup.exe
   gets killed by KillAfterDetection before UDC.exe creates
   udc_settings.json, so the file doesn't exist at ACL-grant time.
   Directory-level ACL with inheritance covers any file created later.

2. Set-MachineNumber.ps1 auto-running: the type-specific loop's
   Get-ChildItem -Filter "*.ps1" picked up the desktop tool alongside
   the numbered installer scripts. Added Where-Object { $_.Name -match
   '^\d' } so only numbered-prefix scripts (01-eDNC, 02-ACLs) run.

3. WJ Shopfloor copy-to-self: Phase 1 sweep moved WJ Shopfloor.lnk
   into Shopfloor Tools\, then Phase 2's Find-ExistingLnk found it
   there and tried to Copy-Item to the same path. Now checks if
   resolved source path == destination and prints "exists: (already
   in Shopfloor Tools)" instead of erroring.

4. NTLARS missing from taskbar pins: the $pinSpec entry was never
   added to 07-TaskbarLayout.ps1 despite the comment update. Added
   between eDNC and Defect_Tracker in pin order.

5. shutdown /a stderr noise: 15+ red "Unable to abort system shutdown"
   lines in the transcript from shutdown.exe writing to stderr when no
   shutdown is pending. Changed all occurrences in Run-ShopfloorSetup,
   00-PreInstall-MachineApps to: cmd /c "shutdown /a 2>nul" *>$null
   which suppresses both native stderr and PS error stream.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-10 09:28:25 -04:00
cproudlock
cb2a9d48a1 Shopfloor: Configure-PC tool, machine-number logon prompt, execution order fixes
New tools:

Configure-PC.bat/.ps1 - Interactive desktop tool for SupportUser to
configure a shopfloor PC after imaging. Two sections:
  1. Machine number: if UDC/eDNC are still at placeholder 9999, prompt
     to set the real number right now (updates UDC JSON + eDNC registry,
     restarts UDC.exe with new args).
  2. Auto-startup toggle: pick which apps start at user logon from a
     numbered list (UDC, eDNC, Defect Tracker, WJ Shopfloor, Plant Apps).
     Creates/removes .lnk files in AllUsers Startup folder. Toggle UI
     shows [ON]/[  ] state, safe to re-run anytime. Plant Apps URL
     resolved from .url file at runtime with hardcoded fallback to
     https://mes-wjefferson.apps.lr.geaerospace.net/run/...
  3. Item 6 in the toggle list: register/unregister a "Check Machine
     Number" logon task for standard (non-admin) users. When enabled,
     the task fires at every logon, checks for 9999, pops an InputBox
     if found, updates both apps, then unregisters itself on success.

Check-MachineNumber.ps1 - The logon task script. Runs as the logged-in
user (needs GUI for InputBox), not SYSTEM. Writing to ProgramData + HKLM
is possible because 02-MachineNumberACLs.ps1 pre-grants BUILTIN\Users
write access on the two specific targets during imaging.

02-MachineNumberACLs.ps1 - Standard type-specific script (runs after
01-eDNC.ps1). Opens C:\ProgramData\UDC\udc_settings.json for Users:Modify
and HKLM:\...\GE Aircraft Engines\DNC\General for Users:SetValue. Narrow
scope, not blanket admin.

Execution order fixes in Run-ShopfloorSetup.ps1:

The dispatcher now has two lists: $skipInBaseline (scripts NOT run in the
alphabetical baseline loop) and $runAfterTypeSpecific (scripts run
explicitly after type-specific scripts complete). This fixes the bug where
06/07 ran before 01-eDNC.ps1 installed DnC, so eDNC/NTLARS shortcuts were
silently skipped.

New execution order:
  Baseline: 00-PreInstall, 04-NetworkAndWinRM (skipping 05-08 + tools)
  Type-specific: 01-eDNC, 02-MachineNumberACLs
  Finalization: 06-OrganizeDesktop, 07-TaskbarLayout

06 internally calls 05 (Office shortcuts, Phase 0) and 08 (Edge config,
Phase 4) as sub-phases, so they also benefit from running late. Office
isn't installed until after the first reboot (ppkg streams C2R), so 05
no-ops at imaging time but succeeds when 06's SYSTEM logon task re-runs
it on the second boot. 08 resolves startup-tab URLs from .url files
delivered by DSC (even later); same self-heal via the logon task.

Other fixes in this commit:

- OpenText Setup-OpenText.ps1 Step 4: exclude WJ_Office.lnk, IBM_qks.lnk,
  mmcs.lnk desktop shortcuts (matching the Step 3 .hep profile exclusion
  from the previous commit). Removes stale copies from prior installs.
- 05-OfficeShortcuts.ps1: widened Office detection to 6 path variants
  covering C2R + MSI + Office15/16, with diagnostic output on miss.
- 06-OrganizeDesktop.ps1: removed Phase 3 (desktop-root pin copies for
  eDNC/NTLARS) so shortcuts live in Shopfloor Tools only, not duplicated
  at root. Emptied $keepAtRoot. Added Phase 0 (call 05) and Phase 4
  (call 08). Lazy folder creation + empty-folder cleanup. Scheduled task
  now runs as SYSTEM (was BUILTIN\Users with Limited which failed the
  admin check). Added NTLARS to 07's taskbar pin list.
- 08-EdgeDefaultBrowser.ps1: Plant Apps URL fallback hardcoded from
  device-config.yaml.
- All new scripts have Start-Transcript logging to C:\Logs\SFLD\ with
  timestamps and running-as identity.
- Run-ShopfloorSetup.ps1: Start-Transcript + Stop-Transcript wrapping
  entire dispatcher run, writes to C:\Logs\SFLD\shopfloor-setup.log.
  Configure-PC.bat added to SupportUser desktop copy list.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-10 08:44:28 -04:00
cproudlock
900180cd12 Shopfloor: desktop folder org, taskbar pins, Edge defaults
Three new baseline scripts that run during shopfloor imaging to clean up
the end-user Public Desktop. Before this, Azure AD users logged into a
shopfloor PC and saw 20+ loose shortcuts at the desktop root (Office
apps, OpenText sessions, WJ web portals, DNC utilities, Defect Tracker,
plus .url files for every intranet page) with no organization. End users
couldn't find anything.

06-OrganizeDesktop.ps1 - Single source of truth for Public Desktop layout
  Phase 1: sweeps loose shortcuts at the desktop root into three category
    folders - Office\, Shopfloor Tools\, Web Links\ - by filename regex,
    extension, and .lnk target resolution. Allowlists eDNC.lnk and
    NTLARS.lnk to stay at root since end users click them too often.
    Unknown items are left at the root on purpose (never delete).
  Phase 2: materializes specific app shortcuts into Shopfloor Tools\.
    UDC / eDNC / NTLARS are built fresh from their .exe paths; WJ
    Shopfloor and Defect_Tracker are MSI-advertised (empty TargetPath,
    Darwin descriptor) so we copy the existing .lnk from wherever it
    lives via a multi-location lookup. Each entry is conditional on its
    source being present - script runs cleanly on PC types without DnC.
  Phase 3: drops eDNC.lnk and NTLARS.lnk at desktop root from the
    Shopfloor Tools\ copies, so end users have both a folder version
    and a quick-access root version.
  Phase 4: registers an "Organize Public Desktop" scheduled task that
    re-runs phase 1 at every logon. Shortcuts added later by DSC /
    Intune / msiexec get filed automatically without another imaging
    pass. Admin check at the top, -ErrorAction Stop on Register-
    ScheduledTask and directory creation so failures are caught
    instead of printing false success.

07-TaskbarLayout.ps1 - Minimal taskbar pinner
  Checks which .lnk files 06 created in Shopfloor Tools\, then writes
  LayoutModification.xml to the Default User profile with taskbar pins
  in order: Edge, WJ Shopfloor, UDC, eDNC, Defect_Tracker. No shortcut
  creation in this script - all shortcut management lives in 06.
  Missing .lnks are skipped (PC types without DnC just get fewer pins).
  Applies on first logon of new user profiles (Azure AD users after
  enrollment). Existing profiles don't re-read Default User - Windows
  design limitation since 1703, no programmatic fix.

08-EdgeDefaultBrowser.ps1 - Edge as default browser + startup tabs
  Motivated by the ppkg installing Chrome alongside Edge: new Azure AD
  users hit a "Choose your default app" picker on first URL click
  because nothing is marked default. Two layers:
    1. dism /Online /Import-DefaultAppAssociations:<xml> writes an XML
       with Edge ProgIds for http/https/.htm/.html/.pdf/.svg/.webp into
       the Default User profile template. New profiles inherit.
    2. HKLM:\SOFTWARE\Policies\Microsoft\Windows\System\
       DefaultAssociationsConfiguration registry value (the "Set a
       default associations configuration file" GPO) points at the same
       XML so Windows re-applies on every logon, catching Windows-update
       defaults-reset cases.
  Leaves Chrome installed, just not the default URL handler.

  Also sets Edge startup tabs via machine-wide policies under
  HKLM:\SOFTWARE\Policies\Microsoft\Edge:
    RestoreOnStartup      = 4 (open specific URLs)
    RestoreOnStartupURLs  = Plant Apps, WJ Shop Floor Homepage, Shopfloor
                            Dashboard (tab order per spec)
    HomepageLocation      = first tab (Plant Apps)
    HomepageIsNewTabPage  = 0
    ShowHomeButton        = 1
  URLs are resolved dynamically from the .url files on the Public
  Desktop (or Web Links\ after the sweep), so if WJDT changes a URL
  later the script picks it up without a code change. Fallbacks are
  hardcoded for the two portals we have URLs memorized for; Plant Apps
  has no fallback and will be skipped if the .url file is missing.

Test workflow: admin-check in all three scripts fails fast on non-
elevated runs instead of spamming half-successful Access Denied output
like the first draft did.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-09 14:38:38 -04:00
cproudlock
c464f45f4f Shopfloor sync_intune + Set-MachineNumber hardening
Long debugging round on the shopfloor test PC with several overlapping
bugs. This commit folds all the fixes together.

sync_intune.bat
- Slim down to an elevation thunk that launches a NEW elevated PS
  window via Start-Process -Verb RunAs (with -NoExit so the window
  doesn't vanish on error). All UI now lives in the PS monitor, not
  mixed into the cmd launcher.
- Goto-based control flow. Earlier version had nested if (...) blocks
  with literal parens inside echo lines (e.g. "wrappers (Install-eDNC,
  ...etc)."); cmd parses if-blocks by counting parens character-by-
  character, so the ")" in "etc)." closed the outer block early and
  the leftover "." threw ". was unexpected at this time.", crashing
  the elevated cmd /c window before pause ran.
- Multi-location Monitor-IntuneProgress.ps1 lookup so the user's
  quick-test workflow (drop both files on the desktop) works without
  manually editing the hardcoded path. Lookup order:
    1. %~dp0lib\Monitor-IntuneProgress.ps1
    2. %~dp0Monitor-IntuneProgress.ps1
    3. C:\Users\SupportUser\Desktop\Monitor-IntuneProgress.ps1
    4. C:\Enrollment\shopfloor-setup\Shopfloor\lib\Monitor-IntuneProgress.ps1
- Prints "Launching: <path>" as its first line so you can see which
  copy it actually loaded. This caught a bug where a stale desktop
  copy was shadowing the canonical file via fallback #2.

Set-MachineNumber.bat
- Same multi-location lookup pattern. Old version used
  %~dp0Set-MachineNumber.ps1 and bombed when the bat was copied to
  the desktop without its .ps1 sibling.
- Goto-based dispatch, no nested parens, for the same parser reason.

Monitor-IntuneProgress.ps1
- Start-Transcript at the top, writing to C:\Logs\SFLD\ (falls back
  to %TEMP% if C:\Logs\SFLD isn't writable yet) with a startup banner
  including a timestamp. Every run leaves a captured trace.
- Main polling loop wrapped in try/catch/finally. Unhandled exceptions
  print a red report with type, message, position, and stack trace,
  then block on Wait-ForAnyKey so the window can't auto-close on a
  silent crash.
- Console window resize at startup via $Host.UI.RawUI.WindowSize /
  BufferSize, wrapped in try/catch (Windows Terminal ignores it, but
  classic conhost honors it).
- Clear-KeyBuffer / Read-SingleKey / Wait-ForAnyKey helpers. Drain any
  buffered keystrokes from the polling loop before each prompt so an
  accidental keypress can't satisfy a pause prematurely.
- Invoke-SetupComplete / Invoke-RebootPrompt final-state handlers.
  The REBOOT REQUIRED branch now shows a yellow 3-line header, a
  four-line explanation, and a cyan "Press Y to reboot now, or N to
  cancel:" prompt via Read-SingleKey @('Y','N'). Y triggers
  Restart-Computer -Force (with shutdown.exe fallback), N falls
  through to Wait-ForAnyKey.
- Display order: status table FIRST, QR LAST. The cursor ends below
  the QR so the viewport always follows it - keeps the QR on screen
  regardless of window height. Works on both classic conhost and
  Windows Terminal (neither reliably honors programmatic resize).
- Half-block QR renderer: walks QRCoder's ModuleMatrix directly and
  emits U+2580 / U+2584 / U+2588 / space, one output line per two
  matrix rows. Halves the rendered height vs AsciiQRCode full-block.
  Quiet zone added manually via $pad=4 since QRCoder's ModuleMatrix
  doesn't include one. Trade-off: may not be perfectly square on all
  fonts, but the user accepted that for the smaller footprint after
  multiple iterations comparing full-block vs half-block vs PNG popup.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-09 13:30:12 -04:00
cproudlock
cd00d6d2e1 OpenText: track Setup-OpenText scripts in repo, opt-in KillAfterDetection
Two related fixes from a debugging round on the test PC:

1. PreInstall runner: detection-during-install kill is now opt-in via
   "KillAfterDetection: true" on JSON entries that need it. Old behavior
   killed any installer as soon as its detection passed - which broke
   Oracle: Oracle creates its registry key partway through install,
   the runner detected it at the 25s poll, killed msiexec mid-install,
   and msiserver was still doing rollback when the next install (VC++
   2008) started - so VC++ 2008 hit ERROR_INSTALL_ALREADY_RUNNING
   (1618). Only UDC needs the detection-kill (its installer spawns a
   hidden WPF window and never exits). Other installers exit cleanly
   on their own and shouldn't be killed.

2. Track Setup-OpenText scripts in git. The bundled OpenText install
   scripts (Setup-OpenText.ps1, Setup-OpenText.cmd, version.txt) live
   at runtime in /home/camp/pxe-images/main/dependencies/opentext/
   alongside the binary install files (~106 MB of MSI/CAB/MSP/MST plus
   profile content). The binaries stay outside git but the script
   logic and version stamp are mirrored into playbook/preinstall/
   opentext/ here so git history captures changes to the install
   logic and version bumps. README.md explains the workflow.

   Latest Setup-OpenText.ps1 includes:
     - $SourceDir default moved into script body (PowerShell evaluates
       param([string]$X = $PSScriptRoot) defaults at parameter-binding
       time, when $PSScriptRoot may not yet be populated, so the
       default came out as empty string and Join-Path crashed)
     - Logging set up FIRST so any startup error gets captured
     - REBOOT=ReallySuppress dropped from both msiexec calls (base MSI
       and SP1 patch) - OpenText installs shell extensions that hook
       explorer.exe, and Restart Manager closes explorer to replace
       the shell DLLs. With REBOOT=ReallySuppress, RM closed explorer
       but interpreted the relaunch as a "reboot action" and refused
       to do it, leaving the user with no desktop. /norestart on its
       own prevents the actual Windows reboot but lets RM cleanly
       close-and-relaunch explorer mid-install.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-09 12:08:07 -04:00
cproudlock
5eacd1d596 PreInstall runner: surface installer log on EXE failures (LogFile field)
When the runner runs a Type:MSI install it injects /L*v <log> and tails
that log on failure to show what actually went wrong. Type:EXE installs
had no equivalent - if Setup-OpenText.cmd or any other EXE wrapper
failed, the installlog just showed "Exit code 1 - FAILED" with no clue
what happened inside.

Adds an optional LogFile field to JSON entries. When present on a
Type:EXE entry, the runner:
  - Logs "Installer log: <path>" before launching the installer
  - On failure, tails the last 30 lines of that file into the runner
    log (same pattern as the MSI verbose log scan)

Wired up on the OpenText entry to point at C:\Logs\PreInstall\Setup-
OpenText.log (which Setup-OpenText.ps1 already writes itself). Other
EXE entries can opt in by adding their own LogFile field.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-09 11:19:45 -04:00