PC-DMIS writes settings, probe configs, and measurement data to its own
Program Files install directory at runtime. Without Modify permission
for BUILTIN\Users, non-admin accounts (ShopFloor) get a UAC elevation
prompt on every launch. The "run as admin once" workaround can't be
automated because PC-DMIS shows a license dialog on first run that
blocks silently.
Fix: grant BUILTIN\Users Modify with inheritance on:
- C:\Program Files\Hexagon\PC-DMIS 2016.0 64-bit
- C:\Program Files\Hexagon\PC-DMIS 2019 R2 64-bit
- C:\ProgramData\Hexagon
Runs as Step 2.5 in 09-Setup-CMM.ps1 after Install-FromManifest
completes. If the exe also has an embedded requireAdministrator manifest
(separate from the file-permission issue), that will need an additional
fix after testing.
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
Rolls up everything from the CMM imaging test iteration tonight. No
single concern - several small, related polish items on the option-3
patched-MSI pipeline and the shopfloor-setup / sync_intune handoff.
- Rename all type-specific "01-Setup-<Type>.ps1" scripts to
"09-Setup-<Type>.ps1" across CMM, Display, Genspect, Keyence, Lab,
and WaxAndTrace. The "01-" prefix implied the script runs first in
the overall sequence when it actually runs between baseline (00, 04)
and finalization (06, 07). Logs now read "Running CMM setup:
09-Setup-CMM.ps1" which matches the real position. Standard/
01-eDNC.ps1 + 02-MachineNumberACLs.ps1 left alone - those digits
represent real within-type ordering.
- playbook/shopfloor-setup/site-config.json CMM profile updates:
- startupItems = [] (empty). Previously had WJ Shopfloor auto-launch
which the user does not want on CMM workstations. Now relies on
the Get-ProfileValue empty-array fix to not fall through to site
defaults.
- desktopApps + taskbarPins gain entries for PC-DMIS 2016, PC-DMIS
2019 R2, CLM Admin, and goCMM so 06-OrganizeDesktop Phase 2
materializes them into C:\\Users\\Public\\Desktop\\Shopfloor Tools\\
and 07-TaskbarLayout pins them. goCMM is under C:\\Program Files
(x86)\\General Electric\\goCMM\\ (GE product, not Hexagon).
- playbook/shopfloor-setup/Run-ShopfloorSetup.ps1: remove the blocking
"UNPLUG ethernet cable, press any key" prompt + the interactive
wired-NIC re-enable. The whole prompt block was a hard blocker on
the imaging chain that required a human to walk to each PC.
- playbook/shopfloor-setup/Shopfloor/lib/Monitor-IntuneProgress.ps1:
re-enable wired NICs unconditionally at the top of the transcript.
This is the new home for the re-enable that used to live behind the
prompt in Run-ShopfloorSetup. By the time sync_intune fires (after
PPKG reboot + auto-login + Stage-Dispatcher), the tech has had
minutes of wall-clock time to physically rewire from PXE to
production without us blocking on a keypress. Tower case is a
no-op because migrate-to-wifi.ps1 already left wired enabled.
- Internal comment updates in 09-Setup-CMM.ps1, cmm-manifest.json,
Install-FromManifest.ps1, and startnet.cmd (+ startnet-template)
to reflect the new filename.
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>