Push stages 2-6 to dashboard before going dark. Wired stays up through
PPKG enrollment so all standard imaging progress lights up the dashboard
card. Disable fires AFTER idx=6 push (handoff to Monitor PostPpkg) +
BEFORE PostPpkg settle's Schedule #3 hammer + BEFORE the PPKG-driven
reboot + BEFORE IME starts firing Report IP. Result: dashboard shows
2-6 cleanly, dark from 6 to 7, then catches up at 7 with QR.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Recurring Phase 2 "Device Configuration" stuck: GE Intune Proactive
Remediation "Report IP" script enumerates Get-NetIPAddress and POSTs
all IPs to a GE webhook. Bays cabled to air-gapped PXE LAN have
10.9.100.x leak into that report. GE backend tags bays "not on corp
net" -> dynamic-group assignment-filter at GE excludes them from the
SFLD ConfigurationProfile (Function + SasToken OMA-URI) ->
HKLM:\SOFTWARE\GE\SFLD\DSC never populates -> Monitor Phase 2 gate
never closes. Confirmed via mdm-diag-F907T5X3 dump: every Microsoft
policy delivered fine, zero SFLD/GE-namespace OMA-URI present.
Fix flow:
1. Run-ShopfloorSetup line 43: disable every Up wired NIC right after
stage 2 push. NIC names persisted to
C:\Enrollment\disabled-wired-nics.txt for later re-enable.
2. Stages 3-6 status pushes fail silently while wired is down (PXE
server lives on the air-gapped 10.9.100.0/24 LAN, unreachable from
WiFi). Dashboard goes dark in that window.
3. PPKG installs, immediate reboot, AAD/Intune enroll over WiFi only.
4. IME boots, Report IP script fires with corp-WiFi IP only, writes
C:\Logs\GE_Report_IP_Address*.txt. Webhook records clean IP. GE
dynamic group eligibility flips. SFLD policy delivers next sync.
5. Monitor-IntuneProgress detects the log file, re-enables every NIC
in the persisted list, sleeps 1s for link, then pushes idx=7 with
DeviceId so the dashboard card flips to QR before the Intune-
triggered LAPS-prompt reboot lands.
Phase 1 remains "in progress" on the dashboard until Report IP fires
- correct, the bay isn't actually registration-clean until then.
Files:
- Disable-WiredNics.ps1 (new) - persists names + disables
- Run-ShopfloorSetup.ps1 - call after stage 2 Report-Stage
- Monitor-IntuneProgress.ps1 - gate idx=7 push + re-enable
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Empirical evidence: MDM baseline policy push lands well within 60s
after PPKG triggers immediate reboot path on bays where assignment
filter matches. Bays where it doesn't deliver in 60s aren't going
to deliver in 180s either - they're blocked on an assignment-filter
or dynamic-group lag (sometimes 30+ min in GCC-High), not on the
raw sync window. Trimming 120s of dead wait off every imaging cycle.
Aggressive 30s Schedule #3 hammer + early-exit on baseline (>=5
subkeys) preserved - those still help bays that DO deliver fast.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Run-ShopfloorSetup.ps1 is copied by startnet.cmd to W:\Enrollment\
(root of Enrollment, NOT inside shopfloor-setup/). So $PSScriptRoot is
W:\Enrollment\. The dot-source path was Join-Path $PSScriptRoot
'Shopfloor\lib\Send-PxeStatus.ps1' which resolves to
W:\Enrollment\Shopfloor\lib\Send-PxeStatus.ps1 - that path does not
exist.
The actual file lands at W:\Enrollment\shopfloor-setup\Shopfloor\lib\
Send-PxeStatus.ps1 (xcopied by startnet from the Shopfloor share dir
into the shopfloor-setup\ subdir). Test-Path returned false, dot-source
silently skipped, Send-PxeStatus was never defined, every Report-Stage
call no-op'd, no log file was written, no POSTs reached the dashboard.
Symptom: bay reaches Windows desktop + runs Run-ShopfloorSetup but
never appears on /imaging dashboard. C:\Logs\send-pxe-status.log does
not exist on the bay.
Fix: add the missing 'shopfloor-setup\' segment so the path resolves
to the actual file location.
09-Setup-*.ps1 use a different relative path ('..\Shopfloor\lib\...')
from inside the per-type dir and were unaffected. Monitor-IntuneProgress
sits in Shopfloor\lib already and uses a sibling lookup - also fine.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Previously the stage indices reflected logical milestones but not the
order they fire in. Run-ShopfloorSetup posted idx=1 (start) and idx=4
(PPKG) - but 09-Setup-Keyence (inside per-type loop) ran BETWEEN them
and posted idx=5/6. The dashboard then "regressed" from 6 back to 4
when PPKG fired, making it look stuck at the per-type-complete card.
New numbering matches actual execution order:
1 - WinPE: PESetup / WIM apply (startnet.cmd)
2 - Run-ShopfloorSetup: starting (Run-ShopfloorSetup.ps1)
3 - 09-Setup-<Type>: starting (per-type)
4 - 09-Setup-<Type>: complete (per-type)
5 - Run-ShopfloorSetup: PPKG enrollment (Run-ShopfloorSetup.ps1)
6 - Run-ShopfloorSetup: handoff to Monitor (Run-ShopfloorSetup.ps1)
7 - Monitor-IntuneProgress: Intune Device ID captured
services/imaging_status.py rewind threshold reverts to stage_index <= 1
now that WinPE startnet posts idx=1.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Adds end-to-end progress tracking for PXE imaging sessions and surfaces
each Blancco report's BIOS serial in the report list.
webapp:
* services/imaging_status.py - JSON-per-serial state store under
IMAGING_DIR (default /var/log/pxe-imaging). Atomic write via
tempfile + rename. log_tail capped at 50 lines. Merges partial
updates so clients can post just the current_stage tick.
* config.py - new IMAGING_DIR env-overridable path.
* services/csrf.py - explicit exempt list for machine-to-machine
endpoints; /imaging/status is the first entry. Air-gapped LAN;
trust-by-network for client posts.
* app.py - four new routes:
GET /imaging dashboard (renders all sessions)
POST /imaging/status client status push (JSON body)
GET /imaging/<serial>.json raw session JSON for ad-hoc polling
POST /imaging/delete/<s> clear a session from the dashboard
Also parses each Blancco XML in the /reports list to surface
system.serial + system.model columns.
* templates/imaging.html - Bootstrap dashboard with per-session
cards (state badge, progress bar, stage idx/total, mac, elapsed,
log tail). meta http-equiv refresh=5 for auto-tick.
* templates/base.html - new "Imaging Progress" nav entry.
* templates/reports.html - Serial + Model columns added.
playbook:
* shopfloor-setup/Shopfloor/lib/Send-PxeStatus.ps1 - new helper.
Dot-source this then call Send-PxeStatus -Stage X -StageIndex N
-StageTotal M from any stage script. BIOS serial via CIM, MAC via
Get-NetAdapter, pctype + machinenumber from C:\Enrollment.
Failures are swallowed to a local log so a network blip doesn't
block imaging.
* shopfloor-setup/Run-ShopfloorSetup.ps1 - dot-sources helper +
posts at three coarse milestones (start, PPKG enrollment,
handoff to Monitor-IntuneProgress).
* shopfloor-setup/gea-shopfloor-keyence/09-Setup-Keyence.ps1 -
posts at session start + after Install-FromManifest with
succeeded/failed status derived from $rc. Other 09-Setup-*.ps1
scripts can follow the same pattern.
ID is BIOS serial (stable across WinPE -> Windows transition and
across reboots, unlike hostname which is random pre-PPKG). Operator
already knows the serial of the bay they imaged.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Display kiosk user cannot authenticate to the tsgwp00525 SFLD share,
so any share-dependent enforcement task on Displays would fail every
cycle. Display is now self-contained: kiosk EXE installs at imaging
time via preinstall.json (Install-KioskApp.cmd) and Edge kiosk
policies via 09-Setup-Display.ps1. No ongoing SFLD-share dependency.
Gate both registrations behind a $noEnforceTypes alias group so
either pcType form (Display, gea-shopfloor-display) hits the skip
path. Other PC types still register both tasks unchanged.
Verified on win11 VM: matrix test confirmed Display + gea-shopfloor-
display SKIP both gates while Standard / CMM / gea-shopfloor-
collections still REGISTER.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Block run-enrollment when this PC has no WiFi adapter and no default
route. PXE imaging LAN has no DHCP gateway, so towers without WiFi
get stuck in PPKG enrollment (AAD + Intune endpoints unreachable)
and require a re-image. Recurring failure mode observed 2026-05-05.
Tech-facing R/X retry+abort prompt walks them through plugging into
a corp wall jack.
Replace plain post-PPKG reboot with handoff to Monitor-IntuneProgress
-PostPpkg: cancel the pending shutdown timer, run a 180s settle so
MDM can push the baseline policy, render live status during settle,
then issue a clean reboot. The persistent @logon sync_intune task
resumes tracking on the next boot.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Filter by PhysicalMediaType + HardwareInterface instead of
InterfaceDescription regex. Name/description varies per vendor
(Realtek Gaming GbE, Intel I219-V, etc.) so a name-only filter
missed adapters on some hardware. Keep an InterfaceDescription
negative guard for drivers that mis-report PhysicalMediaType.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Pairs with Phase 1+2 from earlier (alias maps in Install-FromManifest,
GE-Enforce, Get-PCProfile, verify-state). See project-shopfloor-rename-reorg
memory for the plan.
Phase 3 (repo + paths):
- git mv per-PC-type dirs to gea-shopfloor-* names:
Standard -> gea-shopfloor-collections
CMM -> gea-shopfloor-cmm
Keyence -> gea-shopfloor-keyence
Genspect -> gea-shopfloor-genspect
WaxAndTrace -> gea-shopfloor-waxtrace
Display -> gea-shopfloor-display
Lab -> gea-shopfloor-common (folded; Timeclock+Lab merge)
- New gea-shopfloor-nocollections/ (clone of collections sans UDC scripts).
- New gea-shopfloor-heattreat/ (placeholder, README only).
- Move Standard/ntlars-backups/ -> _ntlars-backups/ (per-MN, not per-type).
- Run-ShopfloorSetup.ps1: Resolve-PCTypeDir helper walks alias group when
the on-disk dir for the current pcType is missing. Set-MachineNumber
helper-copy gated on collections|nocollections|legacy Standard-Machine.
- Update-MachineNumber.ps1: pcProfiles lookups try gea-shopfloor-collections
first, fall back to legacy Standard-Machine. PowerShell 5.1 compatible
(no null-coalesce).
Phase 4 (startnet.cmd menu):
- Choice 3 "GEA Shopfloor" now drills into a 9-item sub-menu instead of
going straight to enrollment. Sub-cats:
1. Machine with Collections -> gea-shopfloor-collections
2. Machine without Collections -> gea-shopfloor-nocollections
3. Common (Timeclock, Lab) -> gea-shopfloor-common
4. Keyence -> gea-shopfloor-keyence
5. CMM -> gea-shopfloor-cmm
6. Genspect -> gea-shopfloor-genspect
7. Heattreat -> gea-shopfloor-heattreat
8. Wax and Trace -> gea-shopfloor-waxtrace
9. Display -> gea-shopfloor-display
- Office menu (existing 6-option) follows for every sub-cat.
- Machine number prompt only for collections + nocollections.
- pc-subtype.txt + display-type.txt no longer written. PCTYPE is a
single full string (gea-shopfloor-*); subtype-aware code paths fall
back to empty and resolve via the alias map.
- CMM bootstrap stage gate switched from "%PCTYPE%"=="CMM" to
"%PCTYPE%"=="gea-shopfloor-cmm".
Test harness:
- B-enforce/run.sh PCSUBTYPE default changed from "Machine" to "" so
single-arg invocation matches the new single-string scheme. Two-arg
legacy form ("Standard Machine") still works via aliasing.
- B-enforce/tamper.ps1 alias-aware Test-MatrixEntryMatches mirroring
verify-state.ps1.
Smoke-tested on win11 VM as SYSTEM via qga: B-enforce harness 5-phase
cycle (stage / baseline / tamper / heal / idempotent) passes 10/10
with PCType=gea-shopfloor-collections AND with legacy "Standard Machine"
two-arg form.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Two bugs that have been silently masking GE-Enforce registration since
Stage 2a landed 2026-04-22, surfaced when v1 enforcers were retired
(commit 0badfc1) and could no longer cover for the missing v2 registration.
Bug 1: startnet.cmd at imaging time only xcopied Shopfloor\ and the
PCTYPE-specific dir from the imaging share to W:\Enrollment\shopfloor-setup\.
common\ was never copied. v1 dispatchers lived per-pctype and rode in via
the %PCTYPE% xcopy, so this was never noticed. v2's GE-Enforce.ps1 +
Register-GEEnforce.ps1 + lib\Install-FromManifest.ps1 all live in common\
and got skipped at imaging entirely.
Fix: add a third xcopy block for common\, mirroring the Shopfloor\ block
above it. Applies to playbook/startnet.cmd and startnet-template.cmd.
Bug 2: Run-ShopfloorSetup.ps1 line 288 set $commonSetupDir via
'Join-Path $PSScriptRoot common'. Run-ShopfloorSetup.ps1 lives at
C:\Enrollment\Run-ShopfloorSetup.ps1 (xcopied by startnet.cmd), so
$PSScriptRoot resolves to C:\Enrollment, and $commonSetupDir resolved
to C:\Enrollment\common - which is NOT where common\ lives even after
the bug 1 fix (correct path is C:\Enrollment\shopfloor-setup\common\).
The Test-Path -LiteralPath check on Register-GEEnforce.ps1 returned
false silently and GE-Enforce never registered.
Same bug existed for Register-MapSfldShare on line 321.
Fix: $PSScriptRoot -> $setupDir for both. $setupDir was already defined
on line 51 as Join-Path $enrollDir "shopfloor-setup", which is the path
the rest of the script uses consistently.
Pre-v1-cleanup, v1's per-pctype enforcer registrations on lines 322-357
(now deleted) ran independently and covered the gap, so PCs ended up
with v1 enforcers and the user thought v2 was running. Post-cleanup,
this bug means nothing gets registered.
PXE server has been patched directly: boot.wim re-baked with the new
startnet.cmd, /srv/samba/enrollment/shopfloor-setup/Run-ShopfloorSetup.ps1
replaced. New PXE-imaged PCs from this point forward will register
GE-Enforce correctly.
For PCs imaged before this fix: run Deploy-GEEnforce.ps1 from the SFLD
share's _meta/runtime/ to retrofit. Same one-liner used for promoting
v1 PCs to v2.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Stage 2a (GE-Enforce.ps1, landed 2026-04-22) is now the only ongoing-update
enforcer. The legacy per-pctype tasks (Machine-Enforce, Common-Enforce,
CMM-Enforce, Keyence-Enforce, Acrobat-Enforce) were kept as transition
belt-and-suspenders; with retrofitted PCs handled, the v1 path is dead and
gets removed entirely.
Deleted (13 files):
Standard/{Machine-Enforce,Register-MachineEnforce}.ps1
Standard/machineapps-manifest.template.json
common/{Common-Enforce,Acrobat-Enforce,Register-CommonEnforce,Register-AcrobatEnforce}.ps1
common/common-apps-manifest.template.json
CMM/CMM-Enforce.ps1
Keyence/Keyence-Enforce.ps1
{CMM,Keyence,Standard}/lib/Install-FromManifest.ps1 (orphan dups of common/lib)
Trimmed:
Run-ShopfloorSetup.ps1: dropped the legacy register-* invocations (Common,
Machine) and the transition-period comment. Sole enforcer registration
is now Register-GEEnforce.
09-Setup-Keyence.ps1: keeps imaging-time install (step 1); removes the
enforcer staging (step 2) and scheduled-task registration (step 3).
Library lookup repointed to common/lib/Install-FromManifest.ps1.
09-Setup-CMM.ps1: same treatment - keeps .NET 3.5 enable, install,
PC-DMIS ACL grants, and bootstrap cleanup. Library repointed to common/lib.
cmm-manifest.json + keyence-manifest.json: _comment fields updated to
reflect imaging-time-only role (ongoing enforcement now goes through
the v2 share manifests via GE-Enforce).
Verified clean: no orphan references to *-Enforce.ps1 / Register-*Enforce.ps1
/ machineapps-manifest / common-apps-manifest in any code path that runs.
A few historical mentions remain in unmodified header comments (GE-Enforce.ps1,
Deploy-GEEnforce.ps1, Monitor-IntuneProgress.ps1) describing what the new
dispatcher replaced; left as historical context.
Run-ShopfloorSetup.ps1 also picks up an unrelated 1-line hunk adding
SetShopfloorAutoLogon.bat to the desktop-copy list (already in the working
tree from a prior session). The file itself is not yet tracked; the
desktop-copy step is Test-Path-guarded so this is harmless until the
.bat is committed.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Consolidates per-type enforcers (CMM, Keyence, Machine, Common, Acrobat)
into one dispatcher driven by pc-type.txt + site-config and a share-side
manifest layout. Same share is now the single source of truth for routine
software updates without re-imaging.
Runtime:
common/GE-Enforce.ps1 SYSTEM scheduled task. Reads
common/manifest.json plus optional
<pcType>/manifest.json and
<pcType-subType>/manifest.json.
Dispatches each entry through the lib.
Writes _outputs/logs/<hostname>/status.json
on the share after each cycle for fleet
monitoring.
common/Register-GEEnforce.ps1 Task registration. Triggers: AtLogOn +
every 5 min (jittered per-PC from
hostname hash) + daily at 05:45,
13:45, 21:45 EST shift windows.
Unregisters legacy per-type tasks on
install so the two coexist at most for
the duration of a single enforce cycle.
common/Deploy-GEEnforce.ps1 Retrofit helper for already-imaged PCs
(admin-run; copies runtime + registers
task + optional immediate trigger).
Library (common/lib/Install-FromManifest.ps1):
- New Type values: PS1, BAT, File, Registry, INF
- New DetectionMethod values: Always, MarkerFile, ValueMatches, pnputil
- TargetHostnames filter (exact + -like wildcards, ANDed with PCTypes)
- Schema version check (logs WARN on manifest newer than lib MAJOR)
- Auto-writes MarkerFile on successful one-shot PS1/BAT/CMD runs
- MSI log scan on failure surfaces meaningful install errors
- Lib version bumped 2.0 -> 2.1 for TargetHostnames
Observability:
common/monitor-fleet-status.py Scans _outputs/logs/*/status.json for
stale check-ins, failed scopes, and
version drift. Respects scope (dir-name),
PCTypes, and TargetHostnames filters so
entries excluded from a PC do not
false-flag as drift.
Regression harness:
common/test/ Parameterized VM harness + README
covering every action type plus
rollback, bad/missing SFLD creds, and
schema versioning.
Imaging integration:
Run-ShopfloorSetup.ps1 now stages GE-Enforce.ps1 and lib to
C:\Program Files\GE\Shopfloor\ and invokes Register-GEEnforce.ps1
at the end of setup. Legacy Register-CommonEnforce invocation is
kept for the transition; it and the legacy per-type enforcer files
are dead code once Register-GEEnforce runs and will be removed in a
dedicated cleanup pass.
Standard-Machine manifest:
eDNC entry bumped 6.4.3 -> 6.4.5. DetectionValue pinned to the
4-part FileVersion 6.4.5.0 verified against a fresh install in the
Win11 analyzer VM. UDC DetectionValue pinned to 1.0.34 (registry
stores 3-part for UDC; verified live).
scripts/mirror-from-gold.sh:
Restructured around share-root rsyncs (one pass per Samba share)
to close gaps in the prior per-subdir layout: winpeapps/_shared/
Applications (7.5 GB of Adobe + fonts + Java + Office + OpenText
+ printdrivers + wireless + Zscaler), additional winpeapps image
types, and enrollment flat-layout root files. Adds
--skip-clonezilla and --skip-reports.
Verified end-to-end in the Win11 analyzer VM:
- Every action Type and DetectionMethod round-tripped
- PCTypes filter (Oracle excluded on Shopfloor, Firefox included
on Shopfloor and DESKTOP-*, excluded elsewhere)
- TargetHostnames filter (exact, wildcard, no-match)
- Upgrade path: XML hash bump + fleet re-copy
- Rollback path: history-archive restore propagates via enforcer,
fleet converges back without per-PC intervention
- Status writeback + monitor script drift detection
- Graceful degradation on bad creds, missing creds, share
unreachable (all exit 0, log clearly, retry next cycle)
Not in this commit (follow-ups):
- Retire legacy per-type *-Enforce.ps1 files and simplify
09-Setup-*.ps1 scripts (coordinated multi-file cleanup)
- Stage 2b: InUseCheck close-and-reopen, ApplyMode gating,
UpdateWindow, .apply-now.txt sentinel, BITS pre-staging,
1618 mutex retry, PostInstallCheck, Uninstall action
- Management app (manifest CRUD + deploy + rollback + fleet view)
- ShopFloor autologon persistence bug (deferred for next imaging
attempt with live registry evidence)
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
- Register-MapSfldShare.ps1: swap scheduled task for HKLM\Run entry. Task with -GroupId runs in session 0 with no HKCU, so /persistent:yes fails and the drive mapping isn't visible to Explorer. Run key fires at Explorer startup in the interactive user's session with full token + HKCU. Unregisters legacy 'GE Shopfloor Map S: Drive' task for PCs already imaged.
- Run-ShopfloorSetup.ps1: stop bumping AutoLogonCount (99 at start, 4 at end). Windows decrements per-logon and at 0 clears AutoAdminLogon + DefaultPassword, which nukes the lockdown-configured ShopFloor autologon. Re-enable-wired-NICs task now gates on Autologon_Remediation.log 'Autologon set for ShopFloor' instead of SFLD creds, so wired stays off through the whole Intune+DSC+lockdown chain.
- Monitor-IntuneProgress.ps1: Phase 4 treats 'no custom scripts' as COMPLETE when DSC install is done (was WAITING, which stalled the state machine on PC types without scripts). Push retrigger out to 15min when entering lockdown-wait so a stale 5min retrigger doesn't fire mid-Remediation. Removed the AutoLogonCount delete in Invoke-SetupComplete since we no longer set it.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
AutoLogonCount depletion:
Run-ShopfloorSetup set AutoLogonCount=4 for SupportUser. Windows
decrements per-logon; at 0 it clears AutoAdminLogon + DefaultPassword,
nuking the lockdown-configured ShopFloor autologon. Fix: delete
AutoLogonCount in Invoke-SetupComplete before the lockdown reboot.
ShopFloor's Autologon.exe-set config persists indefinitely.
Sync_intune window on ShopFloor:
The marker-check path used 'exit 0' but the task runs with -NoExit,
leaving a dangling PowerShell window on every ShopFloor logon. Fix:
[Environment]::Exit(0) kills the host outright, defeating -NoExit.
S: drive mapping:
Vendor ConsumeCredentials.ps1 calls New-StoredCredential -Persist
LocalMachine (needs admin) before net use. ShopFloor is non-admin so
cred-store fails silently and net use has no auth. Fix: new
Map-SfldShare.ps1 reads HKLM creds and passes them inline to
net use /user: -- no Credential Manager needed, works as Limited.
Register-MapSfldShare updated to stage + reference our script.
Wired NIC re-enable:
SYSTEM task polls for SFLD creds (Phase 5), re-enables wired NICs,
self-deletes. Replaces the broken Enable-NetAdapter in Monitor
(Limited principal can't enable NICs). No-WiFi devices unaffected
(migrate-to-wifi never disables, re-enable is a no-op).
Sync throttle:
15 min retrigger when only waiting for lockdown (was 5 min for all
phases). Avoids interrupting the Intune Remediation script.
Defect Tracker path:
All references corrected to C:\Program Files (x86)\WJF_Defect_Tracker.
QR code retry:
Build-QRCodeText retried every poll cycle until DeviceId appears
(was single-shot that could miss the dsregcmd timing window).
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
Replaces the Acrobat-only enforcer with a generic Common-Enforce that
handles all cross-PC-type apps from one manifest + one scheduled task
on the SFLD share at \\tsgwp00525\shared\dt\shopfloor\common\apps\.
Renames:
Acrobat-Enforce.ps1 -> Common-Enforce.ps1
Register-AcrobatEnforce -> Register-CommonEnforce
acrobat-manifest.json -> common-apps-manifest.json
common.acrobatSharePath -> common.commonAppsSharePath
'GE Acrobat Enforce' task -> 'GE Common Apps Enforce' task
C:\Program Files\GE\Acrobat -> C:\Program Files\GE\CommonApps
Register-CommonEnforce cleans up the legacy 'GE Acrobat Enforce' task
if present from a prior image.
WJF Defect Tracker (replaces ClickOnce):
- Added to preinstall.json (PCTypes=*, fleet-wide imaging-time install)
- MSI staged on PXE at pre-install/installers/
- Added to common-apps-manifest with FileVersion detection on
C:\Program Files\WJF_Defect_Tracker\Defect_Tracker.exe
- site-config + 06-OrganizeDesktop: shortcut changed from ClickOnce
'existing' to exe-path pointing at the MSI-installed binary
- Update workflow: drop new MSI on share, bump DetectionValue
CMM 09-Setup-CMM: added goCMM + DODA to the ACL grant list.
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
Force-Lockdown.bat (SupportUser desktop):
Vendor escape hatch when Intune Lockdown push hasn't applied within
~30 minutes. Self-elevates via UAC, prompts for typed YES confirmation
that an ARTS request is in place, then runs sfld_autologon.ps1.
Register-MapSfldShare.ps1 (every PC type):
The SFLD vendor's 'SFLD - Consume Credentials' scheduled task is
principal-restricted (admin-only) so it fires for SupportUser logon
but not for ShopFloor logon -- ShopFloor lands at the desktop with
no S: drive and no way to reach \\tsgwp00525\shared. Workaround:
register a parallel 'GE Shopfloor Map S: Drive' AtLogOn task with
Principal=BUILTIN\Users + RunLevel=Limited that invokes the vendor's
C:\ProgramData\SFLD\CredentialManager\ConsumeCredentials.ps1 in the
interactive user's session. Vendor script handles cred-store + net use
end to end; we just give it a wider trigger principal. Cross-PC-type
because every shopfloor account needs S:.
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
Reason: Intune DSC's main-category YAML was pushing these to every main
device, including Timeclocks - DSC has no awareness of our pc-subtype
distinction. After UDC/eDNC/NTLARS are removed from the DSC YAML, ongoing
version drift would no longer be corrected. This enforcer replaces that,
scoped correctly by subtype.
Structure mirrors CMM (CMM-Enforce.ps1) and common (Acrobat-Enforce.ps1):
- Machine-Enforce.ps1: SYSTEM logon task; mounts SFLD share with HKLM-
backed creds; hands off to Install-FromManifest.
- machineapps-manifest.template.json: repo reference; authoritative copy
lives on the share at \\tsgwp00525.wjs.geaerospace.net\shared\dt\
shopfloor\main\machineapps\machineapps-manifest.json.
- Register-MachineEnforce.ps1: idempotent setup; stages scripts to
C:\Program Files\GE\MachineApps and registers the task.
- lib/Install-FromManifest.ps1: copy of the common/ version (already has
Type=CMD support).
Sub-type gating belt-and-suspenders:
- Run-ShopfloorSetup.ps1 only calls Register-MachineEnforce when
$pcType -eq "Standard" -and $pcSubType -eq "Machine".
- Machine-Enforce.ps1 itself re-reads pc-subtype.txt and exits early if
not "Machine", so a mistakenly-deployed copy no-ops.
site-config.json:
- Added "machineappsSharePath" to Standard-Machine pcProfile.
Drive letter U: to stay clear of CMM (S:) and Acrobat (T:) enforcers
that may run concurrently at logon.
Update workflow:
drop new UDC/eDNC/NTLARS installer on the SFLD share,
bump DetectionValue in machineapps-manifest.json,
every Machine PC catches up on next user logon.
Acrobat Reader enforcement:
- playbook/shopfloor-setup/common/ is the cross-PC-type staging dir. Mirrors
CMM/ structure (enforce script + its Install-FromManifest copy + manifest
template + register script).
- Acrobat-Enforce.ps1 runs as SYSTEM on every logon, reads
acrobatSharePath from site-config.common, mounts the SFLD share with
the same HKLM-backed credential lookup CMM-Enforce uses, hands the
acrobat-manifest.json from the share to Install-FromManifest.
- Install-FromManifest extended with Type=CMD so it can invoke vendor-
supplied .cmd wrappers (Install-AcroReader.cmd does a two-step MSI+MSP
install that does not fit MSI/EXE types cleanly). cmd.exe /c wraps it
because UseShellExecute=false cannot launch .cmd directly.
- Register-AcrobatEnforce.ps1 stages scripts to C:\Program Files\GE\Acrobat
and registers "GE Acrobat Enforce" scheduled task. Called from
Run-ShopfloorSetup.ps1 right before the enrollment (PPKG) step so it
applies to every PC type, not just CMM.
- acrobat-manifest.template.json is the repo reference; the authoritative
copy lives on the SFLD share at
\\tsgwp00525.wjs.geaerospace.net\shared\dt\shopfloor\common\acrobat\
Bumping Acrobat updates = drop new MSP on share, bump DetectionValue in
manifest; enforcer catches every PC on next logon.
- site-config.json: add "common": { "acrobatSharePath": ... }. Uses a
new top-level block rather than a PC-type-specific one since Acrobat
applies everywhere.
Initial install still happens via the preinstall flow
(Install-AcroReader.cmd during WinPE). The enforcer is the ongoing-
updates side; on a freshly-imaged PC detection passes and it no-ops.
Also in this commit:
- run-enrollment.ps1: provtool.exe argument syntax fix. First test
returned 0x80004005 E_FAIL in 1s because /ppkg: and /log: are not
valid provtool flags; the cmdlet's internal call used positional
path + /quiet + /source. Switched to that syntax.
Rolls up everything from the CMM imaging test iteration tonight. No
single concern - several small, related polish items on the option-3
patched-MSI pipeline and the shopfloor-setup / sync_intune handoff.
- Rename all type-specific "01-Setup-<Type>.ps1" scripts to
"09-Setup-<Type>.ps1" across CMM, Display, Genspect, Keyence, Lab,
and WaxAndTrace. The "01-" prefix implied the script runs first in
the overall sequence when it actually runs between baseline (00, 04)
and finalization (06, 07). Logs now read "Running CMM setup:
09-Setup-CMM.ps1" which matches the real position. Standard/
01-eDNC.ps1 + 02-MachineNumberACLs.ps1 left alone - those digits
represent real within-type ordering.
- playbook/shopfloor-setup/site-config.json CMM profile updates:
- startupItems = [] (empty). Previously had WJ Shopfloor auto-launch
which the user does not want on CMM workstations. Now relies on
the Get-ProfileValue empty-array fix to not fall through to site
defaults.
- desktopApps + taskbarPins gain entries for PC-DMIS 2016, PC-DMIS
2019 R2, CLM Admin, and goCMM so 06-OrganizeDesktop Phase 2
materializes them into C:\\Users\\Public\\Desktop\\Shopfloor Tools\\
and 07-TaskbarLayout pins them. goCMM is under C:\\Program Files
(x86)\\General Electric\\goCMM\\ (GE product, not Hexagon).
- playbook/shopfloor-setup/Run-ShopfloorSetup.ps1: remove the blocking
"UNPLUG ethernet cable, press any key" prompt + the interactive
wired-NIC re-enable. The whole prompt block was a hard blocker on
the imaging chain that required a human to walk to each PC.
- playbook/shopfloor-setup/Shopfloor/lib/Monitor-IntuneProgress.ps1:
re-enable wired NICs unconditionally at the top of the transcript.
This is the new home for the re-enable that used to live behind the
prompt in Run-ShopfloorSetup. By the time sync_intune fires (after
PPKG reboot + auto-login + Stage-Dispatcher), the tech has had
minutes of wall-clock time to physically rewire from PXE to
production without us blocking on a keypress. Tower case is a
no-op because migrate-to-wifi.ps1 already left wired enabled.
- Internal comment updates in 09-Setup-CMM.ps1, cmm-manifest.json,
Install-FromManifest.ps1, and startnet.cmd (+ startnet-template)
to reflect the new filename.
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
Install-ProvisioningPackage triggers an immediate reboot that kills
run-enrollment.ps1 before it can register the sync_intune task or do
any post-install work. BPRT app installs happen on the NEXT boot, not
before the reboot.
Fix: move sync task registration into Run-ShopfloorSetup.ps1, executed
BEFORE calling run-enrollment.ps1. The task is safely registered while
we still have control. Then enrollment installs the PPKG and lets it
reboot. After reboot, BPRT finishes in background, sync task fires at
logon, monitors Intune enrollment (which is independent of BPRT).
Run-ShopfloorSetup.ps1:
- Registers "Shopfloor Intune Sync" @logon task after desktop tool
copies but BEFORE enrollment
- Flushes transcript before calling enrollment (since PPKG reboot
will kill us, ensures log is complete)
- Enrollment is the absolute last call
run-enrollment.ps1:
- Stripped to essentials: find PPKG, rename computer, set OOBE,
Install-ProvisioningPackage
- No BPRT polling (irrelevant - happens after reboot)
- No task registration (already done by caller)
- No shutdown call (PPKG handles it)
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
The imaging chain needs exactly 2 autologons after the first boot
(sync_intune pre-reboot + post-reboot). Setting to 4 adds 2 extra
reboots of margin for unexpected restarts from Windows Update, PPKG
file operations, or script crashes.
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
Em dashes (U+2014) and arrows (U+2192) break PowerShell 5.1 on
Windows when the file has no UTF-8 BOM -- byte 0x94 gets read as
a right double quote in Windows-1252, silently closing strings
mid-parse. This caused run-enrollment.ps1 to fail on PXE-imaged
machines with "string is missing the terminator" at line 113.
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
Two related fixes from the pipeline audit:
1. Stage-Dispatcher race condition (critical):
Run-ShopfloorSetup.ps1 called shutdown /r /t 10 and the dispatcher
had to write the next stage + register RunOnce within that 10-second
window. If disk I/O was slow, the reboot fired before RunOnce was
registered, and the chain broke.
Fix: dispatcher now cancels Run-ShopfloorSetup's pending reboot
(shutdown /a) immediately after it returns, then advances the stage
and registers RunOnce with no time pressure, then initiates its own
shutdown /r /t 5.
2. Dispatcher owns all reboots:
Run-ShopfloorSetup.ps1 now checks the -FromDispatcher flag at the
end. When called by the dispatcher, it schedules shutdown /r /t 30
as a safety net (the dispatcher cancels it immediately). When called
standalone (manual run or legacy FirstLogonCommands), it reboots
directly with /t 10 as before.
This means the dispatcher has full control over the reboot lifecycle:
cancel -> advance stage -> register RunOnce -> reboot. No racing.
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
The stage-file gate in Run-ShopfloorSetup.ps1 would fire even when
called by Stage-Dispatcher.ps1 (because the stage file still contains
"shopfloor-setup"), causing an infinite exit loop.
Fix: Run-ShopfloorSetup now accepts -FromDispatcher switch. The gate
only fires when the switch is absent (i.e. when called by the unattend's
FirstLogonCommands). Stage-Dispatcher passes -FromDispatcher when
invoking Run-ShopfloorSetup, bypassing the gate.
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
Run-ShopfloorSetup.ps1 now checks for C:\Enrollment\setup-stage.txt at
the very top. If the stage file exists (written by run-enrollment.ps1),
the script exits immediately with "deferring to Stage-Dispatcher.ps1
on next logon". This prevents the unattend's FirstLogonCommands chain
from running Run-ShopfloorSetup in the same session as run-enrollment,
which was bypassing the entire staged reboot chain.
Without this gate:
FirstLogonCommand #1: run-enrollment.ps1 (sets stage file + RunOnce)
FirstLogonCommand #2: Run-ShopfloorSetup.ps1 (runs immediately, ignoring stage)
PPKG reboot fires after both complete
Next boot: dispatcher has nothing to do (Run-ShopfloorSetup already ran)
With the gate:
FirstLogonCommand #1: run-enrollment.ps1 (sets stage file + RunOnce)
FirstLogonCommand #2: Run-ShopfloorSetup.ps1 (sees stage file, exits)
PPKG reboot fires
Next boot: RunOnce fires dispatcher, reads "shopfloor-setup", runs
Run-ShopfloorSetup properly (stage file deleted by gate on re-entry)
Also: Monitor-IntuneProgress.ps1 RetriggerMinutes bumped from 3 to 5.
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
1. UDC JSON ACL: set on directory C:\ProgramData\UDC\ with
ContainerInherit+ObjectInherit instead of the file. UDC_Setup.exe
gets killed by KillAfterDetection before UDC.exe creates
udc_settings.json, so the file doesn't exist at ACL-grant time.
Directory-level ACL with inheritance covers any file created later.
2. Set-MachineNumber.ps1 auto-running: the type-specific loop's
Get-ChildItem -Filter "*.ps1" picked up the desktop tool alongside
the numbered installer scripts. Added Where-Object { $_.Name -match
'^\d' } so only numbered-prefix scripts (01-eDNC, 02-ACLs) run.
3. WJ Shopfloor copy-to-self: Phase 1 sweep moved WJ Shopfloor.lnk
into Shopfloor Tools\, then Phase 2's Find-ExistingLnk found it
there and tried to Copy-Item to the same path. Now checks if
resolved source path == destination and prints "exists: (already
in Shopfloor Tools)" instead of erroring.
4. NTLARS missing from taskbar pins: the $pinSpec entry was never
added to 07-TaskbarLayout.ps1 despite the comment update. Added
between eDNC and Defect_Tracker in pin order.
5. shutdown /a stderr noise: 15+ red "Unable to abort system shutdown"
lines in the transcript from shutdown.exe writing to stderr when no
shutdown is pending. Changed all occurrences in Run-ShopfloorSetup,
00-PreInstall-MachineApps to: cmd /c "shutdown /a 2>nul" *>$null
which suppresses both native stderr and PS error stream.
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
New tools:
Configure-PC.bat/.ps1 - Interactive desktop tool for SupportUser to
configure a shopfloor PC after imaging. Two sections:
1. Machine number: if UDC/eDNC are still at placeholder 9999, prompt
to set the real number right now (updates UDC JSON + eDNC registry,
restarts UDC.exe with new args).
2. Auto-startup toggle: pick which apps start at user logon from a
numbered list (UDC, eDNC, Defect Tracker, WJ Shopfloor, Plant Apps).
Creates/removes .lnk files in AllUsers Startup folder. Toggle UI
shows [ON]/[ ] state, safe to re-run anytime. Plant Apps URL
resolved from .url file at runtime with hardcoded fallback to
https://mes-wjefferson.apps.lr.geaerospace.net/run/...
3. Item 6 in the toggle list: register/unregister a "Check Machine
Number" logon task for standard (non-admin) users. When enabled,
the task fires at every logon, checks for 9999, pops an InputBox
if found, updates both apps, then unregisters itself on success.
Check-MachineNumber.ps1 - The logon task script. Runs as the logged-in
user (needs GUI for InputBox), not SYSTEM. Writing to ProgramData + HKLM
is possible because 02-MachineNumberACLs.ps1 pre-grants BUILTIN\Users
write access on the two specific targets during imaging.
02-MachineNumberACLs.ps1 - Standard type-specific script (runs after
01-eDNC.ps1). Opens C:\ProgramData\UDC\udc_settings.json for Users:Modify
and HKLM:\...\GE Aircraft Engines\DNC\General for Users:SetValue. Narrow
scope, not blanket admin.
Execution order fixes in Run-ShopfloorSetup.ps1:
The dispatcher now has two lists: $skipInBaseline (scripts NOT run in the
alphabetical baseline loop) and $runAfterTypeSpecific (scripts run
explicitly after type-specific scripts complete). This fixes the bug where
06/07 ran before 01-eDNC.ps1 installed DnC, so eDNC/NTLARS shortcuts were
silently skipped.
New execution order:
Baseline: 00-PreInstall, 04-NetworkAndWinRM (skipping 05-08 + tools)
Type-specific: 01-eDNC, 02-MachineNumberACLs
Finalization: 06-OrganizeDesktop, 07-TaskbarLayout
06 internally calls 05 (Office shortcuts, Phase 0) and 08 (Edge config,
Phase 4) as sub-phases, so they also benefit from running late. Office
isn't installed until after the first reboot (ppkg streams C2R), so 05
no-ops at imaging time but succeeds when 06's SYSTEM logon task re-runs
it on the second boot. 08 resolves startup-tab URLs from .url files
delivered by DSC (even later); same self-heal via the logon task.
Other fixes in this commit:
- OpenText Setup-OpenText.ps1 Step 4: exclude WJ_Office.lnk, IBM_qks.lnk,
mmcs.lnk desktop shortcuts (matching the Step 3 .hep profile exclusion
from the previous commit). Removes stale copies from prior installs.
- 05-OfficeShortcuts.ps1: widened Office detection to 6 path variants
covering C2R + MSI + Office15/16, with diagnostic output on miss.
- 06-OrganizeDesktop.ps1: removed Phase 3 (desktop-root pin copies for
eDNC/NTLARS) so shortcuts live in Shopfloor Tools only, not duplicated
at root. Emptied $keepAtRoot. Added Phase 0 (call 05) and Phase 4
(call 08). Lazy folder creation + empty-folder cleanup. Scheduled task
now runs as SYSTEM (was BUILTIN\Users with Limited which failed the
admin check). Added NTLARS to 07's taskbar pin list.
- 08-EdgeDefaultBrowser.ps1: Plant Apps URL fallback hardcoded from
device-config.yaml.
- All new scripts have Start-Transcript logging to C:\Logs\SFLD\ with
timestamps and running-as identity.
- Run-ShopfloorSetup.ps1: Start-Transcript + Stop-Transcript wrapping
entire dispatcher run, writes to C:\Logs\SFLD\shopfloor-setup.log.
Configure-PC.bat added to SupportUser desktop copy list.
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
Replace em-dash characters with plain hyphens across the 5 shopfloor
setup scripts (avoids cp1252 mojibake in .bat files and keeps the
PowerShell sources consistent). Also adds [Parameter(Position=1)] to
Write-PreInstallLog so the Level argument can be passed positionally.
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
Adds a local-install pipeline so Standard shopfloor PCs get Oracle, the
VC++ redists (2008-2022), and UDC installed during PXE imaging via Samba
instead of pulling ~215 MB per device from Azure blob over the corporate
WAN. Intune DSC then verifies (already-installed apps are skipped) and
the only Azure traffic on the happy path is ~11 KB of CustomScripts
wrapper polling.
New files:
- playbook/preinstall/preinstall.json — curated app list with PCTypes
filter and per-app detection rules. Install order puts VC++ 2008
LAST so its (formerly) reboot-triggering bootstrapper doesn't kill
the runner mid-loop. (2008 itself now uses extracted vc_red.msi with
REBOOT=ReallySuppress; the reorder is defense in depth.)
- playbook/shopfloor-setup/Shopfloor/00-PreInstall-MachineApps.ps1 —
the runner. Numbered 00- so it runs first in the baseline sequence.
Reads preinstall.json, filters by PCTYPE, polls for completion via
detection check (handles UDC's hung WPF process by killing it once
detection passes), uses synchronous WriteThrough logging that
survives hard reboots, preserves log history across runs.
- playbook/shopfloor-setup/Standard/Set-MachineNumber.{ps1,bat} — desktop
helper for SupportUser. Reads current UDC + eDNC machine numbers,
prompts via VB InputBox, validates digits-only, kills running UDC,
edits both C:\ProgramData\UDC\udc_settings.json and HKLM\…\GE Aircraft
Engines\DNC\General\MachineNo, relaunches UDC. Lets a tech assign a
real machine number to a mass-produced PC without admin/LAPS.
- playbook/sync-preinstall.sh — workstation helper to push installer
binaries from /home/camp/pxe-images/main/ to the live PXE Samba.
Changes:
- playbook/startnet.cmd + startnet-template.cmd — add xcopy to stage
preinstall bundle from Y:\preinstall\ to W:\PreInstall\ during the
WinPE imaging phase, gated on PCTYPE being set.
- playbook/pxe_server_setup.yml — create /srv/samba/enrollment/preinstall
+ installers/ directories and deploy preinstall.json there.
- playbook/shopfloor-setup/Run-ShopfloorSetup.ps1 — bump AutoLogonCount
to 99 at start (defense against any installer triggering an immediate
reboot mid-dispatcher; final line still resets to 2 on successful
completion). Copy Set-MachineNumber.{ps1,bat} to SupportUser desktop
on Standard PCs.
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
- AutoLogonCount reduced from 2 to 1 in Run-ShopfloorSetup.ps1
- Remove default pinned Start Menu tiles and set blank layout for future users
- Add sync_intune.bat: triggers MDM sync and polls for SFLD group policies
- Update README.md and SETUP.md with current project state (boot chain, new
scripts, samba shares, webapp pages, commit history)
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
- Fix check-bios.cmd: replace parenthesized if blocks with goto labels
(cmd.exe fails silently with if/else on network-mapped drives)
- Move BIOS check files to winpeapps/_shared/BIOS for reliable SMB access
- Add network wait loop before BIOS check in startnet.cmd
- Show firmware status in WinPE menu header (BIOS_STATUS variable)
- Add BypassNRO registry key to skip OOBE network requirement
- Refactor download-drivers.py with --parallel N flag (ThreadPoolExecutor)
- Set SupportUser AutoLogonCount to 3 in shopfloor unattend
- Add shutdown -a at start + shutdown /r /t 10 at end of Run-ShopfloorSetup.ps1
- Switch download-drivers.py from wget to curl for reliable stall detection
Co-Authored-By: Claude Opus 4.6 <noreply@anthropic.com>