Commit Graph

2 Commits

Author SHA1 Message Date
cproudlock
df443d5d28 ntlars-backups: normalize all 147 per-bay .reg files to wjfms3 + IP secondary
FMSHostPrimary  -> wjfms3.ae.ge.com  (was a mix of WJFMS3, wjfms3.ae.ge.com,
                   WJFMS3.ae.ge.com, WJFMS3.AE.GE.COM across 147 bays)
FMSHostSecondary -> 10.233.112.158   (was a mix of WJFMS3/4 short + .ae.ge.com)

Reasoning: eDNC's CPreScan + DNCdll CDoPersonnel resolve FMS hosts via MFC
CSocket, which calls inet_addr first then gethostbyname. Modern getaddrinfo
(used by PowerShell / Resolve-DnsName) succeeds on the GE corporate net for
this FQDN, but the legacy gethostbyname path does not - eDNC sits there
unable to resolve. Pinning the secondary to a dotted IP makes inet_addr
succeed before any gethostbyname is attempted, so the secondary connect
always works regardless of resolver state. Primary stays as FQDN so the
hosts file pin (added in a separate change to common/manifest.json) gives
gethostbyname an immediate hit. Both values fit the 20-byte buffer cap
that CPreScan + CDoPersonnel use when reading FMSHost* from registry.

Per-bay backups are consumed by Update-MachineNumber's Import-EDncRegBackup
at imaging time, so freshly-imaged PCs land with correct values. Existing
PCs are healed by the matching Type=Registry drift-catcher entries in the
v2 standard-machine manifest.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-02 16:57:50 -04:00
cproudlock
6db170bf54 Shell defaults + eDNC reg restore from machine-number backups
- 03-ShellDefaults.ps1: Default-User TaskbarAl=0 (left), HKLM policies to
  hide Start Recommended section, kill Bing web search + suggestions,
  disable Cortana. LTSC-honoured; runs fleet-wide via baseline loop.

- ntlars-backups/: 147 per-machine eDNC registry backups renamed to
  flat <MachineNumber>.reg scheme. Historical off-by-one entries from
  the original dump rewritten to match CSV-target MachineNo.

- Standard/03-RestoreEDncConfig.ps1: at imaging time, if tech typed a
  real machine number at PXE (not 9999), import <num>.reg from the local
  staged copy. Restores eFocas IP, PPDCS serial, Hssb relays -- not just
  the bare MachineNo. Skipped on Timeclock / 9999 / missing backup.

- Update-MachineNumber.ps1: when tech later sets a real number from 9999,
  pull <num>.reg from tsgwp00525 SFLD share (ntlarsBackupSharePath in
  site-config) and reg-import it before writing the new MachineNo.

- Restore-EDncReg.ps1: shared helper (Mount-SFLDShare + Import-EDncRegBackup)
  used by both callers.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-15 15:42:21 -04:00