Commit Graph

10 Commits

Author SHA1 Message Date
cproudlock
c2b0c3d35e Share accounts: an older live Blancco release warns instead of failing
A fresh server gets boot-tools/blancco from the USB, which can be an older
Blancco (7.15.1) than our preferences (7.20). The version guard refused to
patch its config.img and the exception failed the whole share apply, so the
first-boot playbook failed. refresh_live_prefs() now returns a warning for
config.img and still writes the served preferences.xml (UEFI path).
2026-10-17 12:40:00 -04:00
cproudlock
fa79f76951 Share accounts: per-site Samba passwords from the webapp
Tools > Share accounts sets the pxe-upload, blancco and clonezilla Samba
passwords. Saving one runs smbpasswd and writes it everywhere it is used:
startnet.cmd in boot.wim (pxe-upload), the served Blancco preferences and
the live config.img (blancco), the iPXE menu's Clonezilla entries
(clonezilla). Refused while a PC is imaging unless forced. Stored 0600 in
UPDATES_DIR/shares/accounts.json, never shown back.

- The stored values are the authority: the playbook only creates the
  Samba accounts, seeds the store from site-vars (pxe_upload_password,
  blancco_smb_password, clonezilla_smb_password) for accounts it does not
  hold, and runs "share_accounts apply" at the end of every run.
- Every startnet save re-pins SHAREPASS, so a restored snapshot cannot
  bring an old password back; new menu blocks use %SHAREUSER%/%SHAREPASS%.
- Shop floor unattend Order 4 reads the login from fetch-source.txt;
  Invoke-PostPpkg deletes that file once the PPKG is applied.
- Upload-Image.ps1 asks for the password unless -Pass is given.
- pxe_admin_password: the Linux pxe login. Required while the box still
  has the shipped "pxe"; set with chpasswd when it differs.
- Blancco site settings now also reach the live config.img (BIOS path).
2026-10-17 12:29:06 -04:00
cproudlock
b9a4d0230d Engineer image: upload the Engineering Layer from the web app
New Engineering Layer tab on the engineer image page. A site uploads
Engineering_Install_v<ver>.exe (keeps prereqs) or a .zip of the whole
extra_engineering payload. The upload is streamed to disk, checked (MZ
header, no unsafe zip paths) and swapped in; the replaced payload is
archived (two kept) with a Restore button. Install-EngineeringLayer.ps1
stays repo-owned and now installs the newest Engineering_Install_v*.exe.

KB: Part 4 becomes Site Content (enrollment package, Engineering Layer,
Blancco site settings, Shop Floor apps) plus a new Adding Shop Floor
Apps section for preinstall.json/postppkg.json. WJ examples removed.
2026-10-16 20:48:25 -04:00
cproudlock
04db6d6605 Generic build for other GE sites: no WJ data, one shopfloor type, Windows USB builder
Everything West Jefferson specific moved out to a separate repo
(pxe-site-wj): NTLARS/UDC/heat-treat backups keyed by WJ machine numbers,
CMM and Wax/Trace bay lists, WJ OpenText profiles, site-config.json, the
WJ preinstall list, and the WJ shopfloor PC types (Collections,
NoCollections, Common, Keyence, CMM, Genspect, HeatTreat, Wax/Trace,
Display, PartMarker) with GE-Enforce, machine numbers and the desktop
layout. The part-marker bench tools moved to their own repo. Dead
scripts removed: build-proxmox-iso, deploy-bios, sync_hardware_models,
mirror-from-gold, pull-bios, startnet-template.cmd.

Shopfloor is one generic type, gea-shopfloor-standard, with today's
timing:
- PPKG at first logon (unattend Order 10, unchanged).
- Install-AppList.ps1 runs C:\PreInstall\preinstall.json during setup.
- A new SYSTEM task, GE Shopfloor Post-PPKG, runs postppkg.json once
  after the post-PPKG reboot. It also clears AutoLogonCount after the
  ShopFloor handover (the Users-level monitor can be denied that HKLM
  write) and removes the Intune Sync task when done.
- Both lists ship empty. A site adds entries and installers.
- WinPE choice 3 goes straight to the PPKG menu. Staging, fetch and heal
  carry only the generic payload. The webapp's shopfloor sub-menu editor
  is gone, and the imaging tiles name the new stages.
- The playbook deploys the empty lists only if missing. It now deploys
  the PowerShell 7 MSI the shopfloor unattend installs, which it never
  did before.

Blancco site settings move into the webapp (Updates > Blancco releases):
business location, licensing Wi-Fi SSID and password. They are rendered
into the served preferences.xml and applied to every staged release, and
are seeded from site-vars (site_name, blancco_wifi_ssid,
blancco_wifi_password) only while none exist. The repo XML carries no
site values; the plaintext Wi-Fi password is gone from it.

New site_name and site_timezone settings: report and evidence-pack site
name, server clock and webapp time zone. No more West Jefferson defaults
in webapp/config.py or the dashboard title. Sync-BPRT.ps1 gets the
server address filled in at download instead of WJ's GE address.

USB on Windows:
- scripts/Build-PxeUsb.ps1 runs the same checks as build-usb.sh. It
  writes one FAT32 CIDATA partition (ISO files plus patched grub.cfg plus
  payload) with diskpart and reads every file back by SHA-256.
- Tested with Windows PowerShell 5.1 in the win11 VM, and the layout
  installs and first-boots in the pxetest VM.
- scripts/stage-usb-share.sh stages the build folder on a share.
- site-content/ is optional for both builders.

KB docs/kb/How_To_Deploy_PXE_Server_New_Site.html: new-site deployment,
Windows only, with a site-vars.yml guide.

Checks: webapp tests pass (5 suites); the unattend lint and playbook
syntax checks pass; every .ps1 parses; there are no WJ hosts, IPs, names
or PC types in playbook/, webapp/, scripts/ or autoinstall/.
2026-10-16 20:37:22 -04:00
cproudlock
606659bf07 webapp: fix review findings (imaging types, NIC status, iPXE gates)
- imaging: coerce client payload and stored session fields to str/int,
  drop lists/dicts; tiles template guards pctype/current_stage; POST
  rejects non-object bodies and non-string serials.
- nic_status: normalise every check-file entry; load nic.conf as-is with
  a [nic] fallback; split interface= lists; keep the check's binding while
  fresh, resolve wildcard sockets from the dnsmasq pin (never True for an
  excluded NIC); mark vanished NICs down; include role bridges; stale or
  future-dated files downgrade to warnings and drop evidence.
- Overview renders the network pill in its own try and shows
  'Network: unknown' when status fails.
- ipxe_update: read every Authenticode signature (all WIN_CERTIFICATE
  entries plus nested SPC_NESTED_SIGNATURE) with openssl; shim swap and
  install need both Microsoft UEFI CA 2011 and 2023; install re-reads
  each file (snponly ipxe.efi only); staged.json schema version, older
  records shown stale and refused; uhci counts as native USB.
- backups describe their files; risky rollbacks need a confirm flag.
- mac_folders: guarded listdir, cached describe, configured TFTP root,
  warning for a shim without ipxe.efi.
- evidence pack: years 2000..2100, 400 days inclusive.
- a11y role=group on quick ranges; progress bar stays full during 'shim'.
- tests/test_review_fixes.py: 29 unittest cases incl. both real shims.
2026-10-15 14:20:24 -04:00
cproudlock
81c2d85301 Webapp: iPXE page stages the dual-signed shim, knows snponly and per-MAC folders
Staging fetches ipxe-shimx64.efi from the ipxe/shim release (sha256 from
GitHub), and uses it instead of the tarball's 2011-only shim when it is
signed under the Microsoft UEFI CA 2023 and trusts the same iPXE CA;
otherwise the tarball shim stays, with the reason shown. snponly.efi and
snponly-shim.efi are managed alongside ipxe.efi and ipxe-shim.efi, each
iPXE build says whether it drives USB itself (kills USB keyboards), and
tftp-unique-root per-MAC folders are listed read-only.
2026-10-14 15:37:14 -04:00
cproudlock
2ed2cbe2e9 Webapp redesign: fixes from the functional regression test
- Unattend: a command's '...' menu stayed open after Move up/down and
  covered the next row's menu, so the next click could stage removing the
  wrong command. The menu now closes and focus returns to its button.
- '...' menus close on an outside click, on Escape and when another
  opens (static/app.js), for every page.
- Drivers: Remove asks to confirm again, as before the redesign. Long zip
  paths in a row body wrap (the page scrolled sideways at 390 px).
- Rollback review returns to the page it was opened from (Dell page or
  Updates overview), for both Cancel and the rollback itself.
- To-do: the ServiceNow period offers a year again (366 days).
- Imaging floor: a search that matches a log-only bay opens that group;
  its open state survives the live refresh. 'Clear all' states the
  number of session files it deletes, hidden finished ones included.
- Dashboard: the image key pattern is valid under the browser's v flag
  (client-side validation was silently skipped).
- Import: allowed_import_source() compares real paths, so
  '<upload dir>/../..' is refused. This path traversal predates the
  redesign; the import moves the source tree, so it mattered.
2026-10-14 14:48:10 -04:00
cproudlock
cc1e76f3ab Webapp redesign phase 4: Updates overview and rollback review
- GET /updates/: one card per updater (Dell, iPXE, Blancco, BPRT) with
  its state, a Check now / Open action and details in accordions; the
  shared download cap is a small popover.
- Dell applies list: one line per apply titled by its first change
  ('Latitude 5350 pack A11 to A12', model looked up in the maps) and
  'and n more'; the chip says how many written files are unchanged since
  the apply. The body lists every change, skipped item, error and file.
- dell_updates.file_status(): per file an apply wrote, unchanged /
  changed / missing by content hash, the same test rollback uses.
  describe(), history_view() and rollback_preview() build on it.
- GET /updates/dell/rollback/<id>: review a rollback before doing it,
  with the files that would be restored and a diff of each. The POST
  route is unchanged; both forms can return to the overview.
2026-10-14 13:54:41 -04:00
cproudlock
6187219378 BPRT sync: point the page and docstrings at static/Sync-BPRT.ps1
Follow-up to 92f1e62, which moved the file but missed these references.
2026-10-13 17:12:51 -04:00
cproudlock
397063f987 Webapp: Updates pages, image page tabs with review-before-save, BPRT sync
Updates group:
- Dell drivers and BIOS: check Dell's catalogs against all three driver maps
  and models.txt, download with a shared speed cap, repack, preview, apply
  with backups and rollback.
- iPXE boot files: check GitHub for the signed Secure Boot set, verify the
  sha256 and each file's signer, install atomically, roll back. Includes the
  by-hand procedure.
- Blancco: upload a release, stage it, test-boot it from the menu, activate,
  roll back.
- BPRT sync: validate a batch uploaded from the MediaCreator Lite cache
  (scripts/windows/Sync-BPRT.ps1 or a zip), show the diff, swap with the site
  overlay files kept.

Images: one sidebar entry per image with Overview, Drivers, Unattend and OS and
Packages tabs. Every save shows a diff first, keeps the file's format, makes a
backup and can be undone. Driver lint runs inline.

Enrollment: upload standard/engineer MCL packages, one per tenant/purpose,
with archive and restore. Hardware coverage counts engineer as Win11.
2026-10-13 16:58:55 -04:00