Single-site bay-stuck issue at WJ: GE Intune Report IP script filters
Get-NetIPAddress on StartsWith("10.") and posts everything matching
to the GE Tines webhook. Bays at WJ get the PXE LAN 10.9.100.x IP
captured and reported -> GE backend tags bays as on a non-corp 10.x
subnet -> dynamic group eligibility for SFLD policy never matches.
Other GE sites work because their PXE LANs aren't on 10.x at all.
Renumber PXE LAN to RFC1918 172.16.9.0/24 so the GE filter naturally
skips wired PXE addresses without any disable-NIC dance.
Server-side already in flight (netplan dual-bound, dnsmasq scope +
boot URL repointed, blancco preferences + grub.cfg + iPXE GetPxeScript
all sed'd to 172.16.9.1). This commit is the playbook / scripts /
docs side: 109 hits across 35 files sed'd in one shot.
After this lands + boot.wim is rebuilt + bays renumber off DHCP,
the 10.9.100.1 binding will be dropped from netplan as the final
cleanup step.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Reverts the 2026-04-24 no-op stub. Empirically the gateway-suppression
fix (dnsmasq dhcp-option=3/=6 empty) alone is NOT sufficient to keep
Windows from using the wired NIC for Intune Device Configuration / DSC
traffic. Even with no default route on wired AND the unattend's
InterfaceMetric trick (WiFi=10, Wired=100), the bay stalls on the DSC
phase until the wired cable is physically unplugged.
Restoring the prior body that disables non-WiFi NICs at first logon
post-PPKG. Gated on Get-NetAdapter for a Wi-Fi/Wireless/WLAN/802.11
adapter - towers without WiFi stay on ethernet (the only-NIC scenario
where disabling would hang first logon). Falls back to re-enabling
ethernet if login.microsoftonline.us:443 doesn't respond within 5 min.
Monitor-IntuneProgress.ps1 already has the symmetric re-enable
("Re-enable any wired NICs that Order 5 disabled") at the start of its
monitor loop, which kicks in after DSC creds land. Net effect: wired
disabled during the DSC fetch window, re-enabled by the time eDNC
autostart needs the local NIC.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Bundles drift left uncommitted from prior sessions and the UDC matrix
verify entry added today.
Drift items (all per session-progress.md, completed in earlier sessions
but never staged):
- playbook/check-bios.cmd (deleted, moved to BIOS/check-bios.cmd)
- playbook/migrate-to-wifi.ps1 (made no-op 2026-04-24 after the dnsmasq
no-gateway fix removed the wired-NIC race that motivated it)
- playbook/preinstall/oracle/Install-Oracle11r2.cmd (post-OUI .ora copy
added 2026-04-24)
- playbook/preinstall/oracle/tnsnames.ora (live tnsnames, 469 KB,
deployed alongside the wrapper 2026-04-24)
- playbook/pxe_server_setup.yml (dnsmasq dhcp-option=3,6 commented,
Oracle .ora deploy task added 2026-04-24)
- playbook/shopfloor-setup/BIOS/{check-bios.cmd, models.txt} (BIOS
detection refinements)
- playbook/shopfloor-setup/Shopfloor/Force-Lockdown.bat
- playbook/shopfloor-setup/Shopfloor/Monitor-IntuneProgress.ps1
- playbook/shopfloor-setup/Shopfloor/SetShopfloorAutoLogon.bat (new)
- playbook/shopfloor-setup/Shopfloor/09-Install-PrinterInstallerMap.ps1
(new, places PrinterInstallerMap.exe + Public Desktop shortcut at
imaging time; manifest entry self-heals on tamper)
- playbook/shopfloor-setup/Shopfloor/lib/Show-IntuneDeviceQR.ps1 (new,
standalone QR rendering for site that wanted just that piece)
- playbook/shopfloor-setup/gea-shopfloor-collections/{Install-eMxInfo.cmd.template,
Restore-UDCData.ps1} (these were uncommitted in pre-rename Standard/;
git mv didn't catch them because they were untracked at the time)
- docs/shopfloor-machine-imaging-guide.md (operator-facing how-to)
Matrix:
- common.test/matrix.json: add UDC verify entry to gea-shopfloor-collections
row. Surfaces UDC silent-install issue (item H pending) instead of
letting it pass silently.
.gitignore:
- PrinterInstallerMap.exe (142 MB) excluded. Track via LFS or stage on
PXE server only - too big for regular git history. Untouched on disk
so existing local copy still works.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
FlatUnattendW10-shopfloor.xml was rejected by Windows OOBE with
"the answer file is invalid" after the earlier tower-no-WiFi fix.
Root cause: the inline PowerShell in <CommandLine> for Orders 4 and
5 exceeded the SynchronousCommand CommandLine length limit (~1024
chars) and/or contained characters the unattend schema validator
dislikes.
Fix: move the logic to two external PS1 scripts and shrink both
CommandLine entries to ~85 chars each that just invoke the scripts.
- playbook/wait-for-internet.ps1: 60s interactive prompt ("connect
production network now"), then poll TCP 443 to login.microsoft-
online.us for up to 10 min with a hard timeout so the loop always
exits. Uses Test-NetConnection -Port 443 (not Test-Connection /
ICMP) because Microsoft 365 edges do not reliably respond to ping.
- playbook/migrate-to-wifi.ps1: Gates the entire wired-disable
migration on "does a WiFi adapter exist?" If not (tower), the
script is a no-op. If yes, disable wired / wait for WiFi internet
with a 5 min timeout / re-enable wired on timeout fallback.
- startnet.cmd stages both new scripts to W:\Enrollment\ next to
run-enrollment.ps1 during the WinPE phase.
- FlatUnattendW10-shopfloor.xml Orders 4 and 5 shrunk to short
invocations of C:\Enrollment\wait-for-internet.ps1 and
C:\Enrollment\migrate-to-wifi.ps1.
- startnet-template.cmd kept in sync.
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>