cproudlock
564f14ffcf PreInstall runner: capture real exit codes, surface MSI errors
Three observability fixes that made the VC++ MSI failures actually
debuggable instead of showing "Exit code  - FAILED" with an empty
value for every install:

1. Switch from Start-Process -PassThru (without -Wait) to
   [System.Diagnostics.Process]::Start() with a ProcessStartInfo.
   PowerShell 5.1 has a known bug where Start-Process disposes the
   Process object's OS handle when control returns to the script,
   so $proc.ExitCode reads as $null even after WaitForExit() - which
   was causing every MSI install to be reported as failed regardless
   of the actual result.

2. Pass /L*v <log> to msiexec on every MSI install so we get a full
   verbose log per app at C:\Logs\PreInstall\msi-<safename>.log.

3. On install failure, scan the verbose log for *meaningful* lines
   (Note: 1: <code>, "return value 3", custom action errors, "Failed
   to", "Installation failed", common 2xxx error codes) instead of
   tailing the last 25 lines, which is rollback/cleanup noise. This
   surfaces the actual root-cause line directly in the runner log so
   you don't have to dig through C:\Logs to diagnose.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-09 10:08:42 -04:00
cproudlock
ded0a7184b Shopfloor scripts: em-dash to hyphen, add positional Level param
Replace em-dash characters with plain hyphens across the 5 shopfloor
setup scripts (avoids cp1252 mojibake in .bat files and keeps the
PowerShell sources consistent). Also adds [Parameter(Position=1)] to
Write-PreInstallLog so the Level argument can be passed positionally.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-08 14:24:37 -04:00
cproudlock
a1a78e2ba3 PXE preinstall pipeline + Set-MachineNumber helper for Standard PCs
Adds a local-install pipeline so Standard shopfloor PCs get Oracle, the
VC++ redists (2008-2022), and UDC installed during PXE imaging via Samba
instead of pulling ~215 MB per device from Azure blob over the corporate
WAN. Intune DSC then verifies (already-installed apps are skipped) and
the only Azure traffic on the happy path is ~11 KB of CustomScripts
wrapper polling.

New files:
- playbook/preinstall/preinstall.json — curated app list with PCTypes
  filter and per-app detection rules. Install order puts VC++ 2008
  LAST so its (formerly) reboot-triggering bootstrapper doesn't kill
  the runner mid-loop. (2008 itself now uses extracted vc_red.msi with
  REBOOT=ReallySuppress; the reorder is defense in depth.)
- playbook/shopfloor-setup/Shopfloor/00-PreInstall-MachineApps.ps1 —
  the runner. Numbered 00- so it runs first in the baseline sequence.
  Reads preinstall.json, filters by PCTYPE, polls for completion via
  detection check (handles UDC's hung WPF process by killing it once
  detection passes), uses synchronous WriteThrough logging that
  survives hard reboots, preserves log history across runs.
- playbook/shopfloor-setup/Standard/Set-MachineNumber.{ps1,bat} — desktop
  helper for SupportUser. Reads current UDC + eDNC machine numbers,
  prompts via VB InputBox, validates digits-only, kills running UDC,
  edits both C:\ProgramData\UDC\udc_settings.json and HKLM\…\GE Aircraft
  Engines\DNC\General\MachineNo, relaunches UDC. Lets a tech assign a
  real machine number to a mass-produced PC without admin/LAPS.
- playbook/sync-preinstall.sh — workstation helper to push installer
  binaries from /home/camp/pxe-images/main/ to the live PXE Samba.

Changes:
- playbook/startnet.cmd + startnet-template.cmd — add xcopy to stage
  preinstall bundle from Y:\preinstall\ to W:\PreInstall\ during the
  WinPE imaging phase, gated on PCTYPE being set.
- playbook/pxe_server_setup.yml — create /srv/samba/enrollment/preinstall
  + installers/ directories and deploy preinstall.json there.
- playbook/shopfloor-setup/Run-ShopfloorSetup.ps1 — bump AutoLogonCount
  to 99 at start (defense against any installer triggering an immediate
  reboot mid-dispatcher; final line still resets to 2 on successful
  completion). Copy Set-MachineNumber.{ps1,bat} to SupportUser desktop
  on Standard PCs.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>