Click effect: button flashes green with "copied!" text and 1.15x
scale pulse, reverts after 1.2s. Failure case (clipboard API blocked
or HTTP context) shows red "failed" for 1.5s. Handler moved out of
inline onclick into a single delegated click listener at the doc
level so future copy buttons just need the .copy-btn class +
data-copy-text attribute.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Field bay surfaced two bugs in one diag dump (mdm-diag-F907T5X3 -
6PPSF24):
1. GE Proactive Remediation Report IP actually writes
GE_Report_IP_Address_2_5.LOG (uppercase .LOG), not the .txt I
assumed. Globs in two places had .txt filter -> never matched ->
Phase 1 stuck IN PROGRESS forever even after the file landed and
wired-NIC re-enable never fired. Drop extension from both globs
in Monitor-IntuneProgress.ps1 (id=7 push gate + p1Done check).
2. The "GE Re-enable Wired NICs" SYSTEM task registered by
Run-ShopfloorSetup was polling Autologon_Remediation.log for
"Autologon set for ShopFloor" - a lockdown-time signal. Re-enable
needs to fire at Report-IP time (well before lockdown) so that
Monitor can push idx=7 with the QR before the Intune-triggered
LAPS-prompt reboot. Repoint the SYSTEM task's poll to
C:\Logs\GE_Report_IP_Address* (any extension).
Plus minor UX: copy button next to the Intune device ID on
/imaging dashboard so techs can grab the GUID without having to
double-click-select the <code>.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Monitor-IntuneProgress.ps1: the previous Ensure-SendPxeStatus function
ran '. $lib' from inside the function body. PowerShell's dot-source-
inside-function semantics put the imported Send-PxeStatus into the
function's LOCAL scope, not the script scope. By the time Get-Phase1
called Get-Command Send-PxeStatus, the function had already returned
and Send-PxeStatus was out of scope - silently never invoked, no log
entry at all (success or failure). Diagnostic confirmed: bay had
DeviceId in dsregcmd, manual Send-PxeStatus from operator prompt
fired idx=7 cleanly with QR rendered, but Monitor's automatic call
never showed up in C:\Logs\send-pxe-status.log.
Fix: dot-source at script top-level (outside any function). Then
Send-PxeStatus is in script scope where every function in the file
can call it. Keep Ensure-SendPxeStatus as a no-op stub for any caller
still invoking it.
imaging.html: bump QR data-qr-size from 56 to 160 px. A 36-char UUID
at ECC M needs ~29x29 modules; at 56px each module was ~1.5px which
is too tight for a phone camera to lock onto from typical distance.
160 px gives ~5 px/module which scans cleanly.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Adds end-to-end progress tracking for PXE imaging sessions and surfaces
each Blancco report's BIOS serial in the report list.
webapp:
* services/imaging_status.py - JSON-per-serial state store under
IMAGING_DIR (default /var/log/pxe-imaging). Atomic write via
tempfile + rename. log_tail capped at 50 lines. Merges partial
updates so clients can post just the current_stage tick.
* config.py - new IMAGING_DIR env-overridable path.
* services/csrf.py - explicit exempt list for machine-to-machine
endpoints; /imaging/status is the first entry. Air-gapped LAN;
trust-by-network for client posts.
* app.py - four new routes:
GET /imaging dashboard (renders all sessions)
POST /imaging/status client status push (JSON body)
GET /imaging/<serial>.json raw session JSON for ad-hoc polling
POST /imaging/delete/<s> clear a session from the dashboard
Also parses each Blancco XML in the /reports list to surface
system.serial + system.model columns.
* templates/imaging.html - Bootstrap dashboard with per-session
cards (state badge, progress bar, stage idx/total, mac, elapsed,
log tail). meta http-equiv refresh=5 for auto-tick.
* templates/base.html - new "Imaging Progress" nav entry.
* templates/reports.html - Serial + Model columns added.
playbook:
* shopfloor-setup/Shopfloor/lib/Send-PxeStatus.ps1 - new helper.
Dot-source this then call Send-PxeStatus -Stage X -StageIndex N
-StageTotal M from any stage script. BIOS serial via CIM, MAC via
Get-NetAdapter, pctype + machinenumber from C:\Enrollment.
Failures are swallowed to a local log so a network blip doesn't
block imaging.
* shopfloor-setup/Run-ShopfloorSetup.ps1 - dot-sources helper +
posts at three coarse milestones (start, PPKG enrollment,
handoff to Monitor-IntuneProgress).
* shopfloor-setup/gea-shopfloor-keyence/09-Setup-Keyence.ps1 -
posts at session start + after Install-FromManifest with
succeeded/failed status derived from $rc. Other 09-Setup-*.ps1
scripts can follow the same pattern.
ID is BIOS serial (stable across WinPE -> Windows transition and
across reboots, unlike hostname which is random pre-PPKG). Operator
already knows the serial of the bay they imaged.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>