Tech catches a PC imaged with a wrong machine number. Previously the
share restore (NTLARS .reg + UDC settings + UDC live data) only fired
on the placeholder->real transition, so a real->real change rewrote
only UDC JSON, eDNC reg, and MTConnect Devices.xml - leaving the wrong
NTLARS config in place.
Update-MachineNumber.ps1: replace the placeholder-only guard with an
any-change guard so the share restore block fires on reassign too.
The existing one-shot migrated/ consumption keeps live-data restore
idempotent. Also writes C:\Enrollment\machine-number.txt to keep
imaging-time scripts in sync.
Set-MachineNumber.ps1 (both collections + nocollections): show a
confirmation dialog when reassigning between two real numbers, naming
old/new and listing what gets pulled. Audit each call to
C:\Logs\Shopfloor\reassign.log.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Pairs with Phase 1+2 from earlier (alias maps in Install-FromManifest,
GE-Enforce, Get-PCProfile, verify-state). See project-shopfloor-rename-reorg
memory for the plan.
Phase 3 (repo + paths):
- git mv per-PC-type dirs to gea-shopfloor-* names:
Standard -> gea-shopfloor-collections
CMM -> gea-shopfloor-cmm
Keyence -> gea-shopfloor-keyence
Genspect -> gea-shopfloor-genspect
WaxAndTrace -> gea-shopfloor-waxtrace
Display -> gea-shopfloor-display
Lab -> gea-shopfloor-common (folded; Timeclock+Lab merge)
- New gea-shopfloor-nocollections/ (clone of collections sans UDC scripts).
- New gea-shopfloor-heattreat/ (placeholder, README only).
- Move Standard/ntlars-backups/ -> _ntlars-backups/ (per-MN, not per-type).
- Run-ShopfloorSetup.ps1: Resolve-PCTypeDir helper walks alias group when
the on-disk dir for the current pcType is missing. Set-MachineNumber
helper-copy gated on collections|nocollections|legacy Standard-Machine.
- Update-MachineNumber.ps1: pcProfiles lookups try gea-shopfloor-collections
first, fall back to legacy Standard-Machine. PowerShell 5.1 compatible
(no null-coalesce).
Phase 4 (startnet.cmd menu):
- Choice 3 "GEA Shopfloor" now drills into a 9-item sub-menu instead of
going straight to enrollment. Sub-cats:
1. Machine with Collections -> gea-shopfloor-collections
2. Machine without Collections -> gea-shopfloor-nocollections
3. Common (Timeclock, Lab) -> gea-shopfloor-common
4. Keyence -> gea-shopfloor-keyence
5. CMM -> gea-shopfloor-cmm
6. Genspect -> gea-shopfloor-genspect
7. Heattreat -> gea-shopfloor-heattreat
8. Wax and Trace -> gea-shopfloor-waxtrace
9. Display -> gea-shopfloor-display
- Office menu (existing 6-option) follows for every sub-cat.
- Machine number prompt only for collections + nocollections.
- pc-subtype.txt + display-type.txt no longer written. PCTYPE is a
single full string (gea-shopfloor-*); subtype-aware code paths fall
back to empty and resolve via the alias map.
- CMM bootstrap stage gate switched from "%PCTYPE%"=="CMM" to
"%PCTYPE%"=="gea-shopfloor-cmm".
Test harness:
- B-enforce/run.sh PCSUBTYPE default changed from "Machine" to "" so
single-arg invocation matches the new single-string scheme. Two-arg
legacy form ("Standard Machine") still works via aliasing.
- B-enforce/tamper.ps1 alias-aware Test-MatrixEntryMatches mirroring
verify-state.ps1.
Smoke-tested on win11 VM as SYSTEM via qga: B-enforce harness 5-phase
cycle (stage / baseline / tamper / heal / idempotent) passes 10/10
with PCType=gea-shopfloor-collections AND with legacy "Standard Machine"
two-arg form.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
When the tech transitions a 9999-placeholder PC to its real machine number,
also restore the per-bay udc_settings_<num>.json from
\\tsgwp00525\shared\spc\udc\settings_backups\. PXE-time preinstall can't reach
this share (no SFLD creds yet), so 00-PreInstall uses the local C:\Enrollment
mirror; post-config the share is reachable, so the renumber path goes direct
to the canonical source.
Adds udcSettingsSharePath to site-config.json under Standard-Machine.
Bundles in prior uncommitted work in the same file: ntlars reg restore,
UDC data restore (CurrentData.json + ArchivedData/), MTConnect Devices.xml
inline rewrite + service restart, and one-shot consume of per-bay UDC
backup -> migrated/<timestamp>/.
Root cause found via decompiling UDC_Setup.exe: it never writes
udc_settings.json from CLI args. Instead it pulls
Settings_Backups\udc_settings_<num>.json from \\tsgwp00525\shared\SPC\UDC
-- which is unreachable at imaging time (no SFLD creds yet). Silent
File.Exists() false, settings never copy, UDC lands on Evendale defaults.
Fix: stage 80 udc_settings_*.json backups under
shopfloor-setup/Standard/udc-backups/ (same tree as ntlars-backups,
xcopy'd to C:\Enrollment\ by existing startnet.cmd). 00-PreInstall
pre-creates C:\ProgramData\UDC\udc_settings.json from the matching
backup BEFORE UDC_Setup.exe runs. Installer's server-side copy silently
fails (unreachable), our pre-staged file survives.
Also:
- preinstall.json UDC InstallArgs corrected: "West Jefferson" -9999
(quoted spaced site + dash-prefixed number, confirmed via decompile)
- Update-MachineNumber.ps1 UDC.exe relaunch: quoted site + dash number
- Monitor-IntuneProgress: action prompts (Select Device Category after
Phase 1; Initiate ARTS Lockdown after Phase 5/creds), Display flow
(3-phase: Registration -> Config -> Lockdown), Phase 6 IME-based
lockdown detection
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
UDC_Setup.exe and UDC.exe expect:
UDC_Setup.exe WestJefferson -7605
Not the spaced-quoted positional pair we'd been passing:
UDC_Setup.exe "West Jefferson" 7605
The wrong format meant UDC ignored both args, fell back to defaults
(Site=Evendale, MachineNumber=blank). Combined with the kill-after-detect
window, neither value got persisted to udc_settings.json regardless of
whether UDC.exe was given time to write.
Changes:
- preinstall.json: UDC InstallArgs now "WestJefferson -9999"
- 00-PreInstall-MachineApps.ps1: site override now matches/replaces
the compact 'WestJefferson' token (not 'West Jefferson') and uses
siteNameCompact from site-config; targetNum extraction regex updated
to '-(\d+)$' for the new dash-prefix format
- Update-MachineNumber.ps1: UDC.exe relaunch now passes positional
compact-site + dash-prefixed number instead of -site/-machine flags
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
- 03-ShellDefaults.ps1: Default-User TaskbarAl=0 (left), HKLM policies to
hide Start Recommended section, kill Bing web search + suggestions,
disable Cortana. LTSC-honoured; runs fleet-wide via baseline loop.
- ntlars-backups/: 147 per-machine eDNC registry backups renamed to
flat <MachineNumber>.reg scheme. Historical off-by-one entries from
the original dump rewritten to match CSV-target MachineNo.
- Standard/03-RestoreEDncConfig.ps1: at imaging time, if tech typed a
real machine number at PXE (not 9999), import <num>.reg from the local
staged copy. Restores eFocas IP, PPDCS serial, Hssb relays -- not just
the bare MachineNo. Skipped on Timeclock / 9999 / missing backup.
- Update-MachineNumber.ps1: when tech later sets a real number from 9999,
pull <num>.reg from tsgwp00525 SFLD share (ntlarsBackupSharePath in
site-config) and reg-import it before writing the new MachineNo.
- Restore-EDncReg.ps1: shared helper (Mount-SFLDShare + Import-EDncRegBackup)
used by both callers.
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
Three optimization batches from the pipeline audit:
1. Shared Update-MachineNumber.ps1 helper (lib/)
Extracts duplicated machine-number update logic from Configure-PC.ps1,
Check-MachineNumber.ps1, and Set-MachineNumber.ps1 into a shared
dot-sourceable helper at Shopfloor/lib/Update-MachineNumber.ps1.
Exports:
Get-CurrentMachineNumber → @{ Udc = $string; Ednc = $string }
Update-MachineNumber -NewNumber <n> [-Site <s>] → @{ UdcUpdated; EdncUpdated; Errors }
All three consumers now dot-source the helper instead of duplicating
~50 lines each. Set-MachineNumber.ps1 also migrated from inline
Get-SiteConfig to dot-sourcing Get-PCProfile.ps1 for consistency.
2. Site-config integration for remaining scripts
Setup-OpenText.ps1: exclude lists (profiles + shortcuts) now read from
site-config.json opentext section, falling back to West Jefferson
defaults. Inline Get-SiteConfig since the script runs from
C:\PreInstall\installers\opentext\ (can't dot-source Get-PCProfile).
00-PreInstall-MachineApps.ps1: after parsing preinstall.json, scans
InstallArgs for "West Jefferson" and replaces with site-config
siteName if different. Inline Get-SiteConfig for same reason.
3. Placeholder type-specific directories
Created skeleton 01-Setup-*.ps1 scripts for all PC types so the
directory structure is in place and Run-ShopfloorSetup's type-specific
loop has something to iterate over:
Genspect/01-Setup-Genspect.ps1
Keyence/01-Setup-Keyence.ps1
WaxAndTrace/01-Setup-WaxAndTrace.ps1
Lab/01-Setup-Lab.ps1
Each logs a "no type-specific apps configured yet" banner and exits.
Fill in app installs when details are finalized; for share-based
installs, copy the CMM/01-Setup-CMM.ps1 pattern.