GE-Enforce mounts the SFLD share on W: and holds it for the whole enforce
cycle, passing W:\<pctype> as -InstallerRoot to Install-FromManifest. Two
scripts that run inside that cycle, as SYSTEM in the same drive namespace,
mapped W: for their own use and deleted it on exit:
Restore-UDCData.ps1 manifest PS1 entry, mounts the UDC backup share
Update-MachineNumber.ps1 "Apply Machine Number" task, same backup share
Once W: is gone, the next manifest entry's Join-Path resolves against a dead
drive qualifier. In Windows PowerShell 5.1 that emits nothing rather than
throwing, so the null lands in Test-Path -LiteralPath and the entry dies with
"Cannot bind argument to parameter 'LiteralPath' because it is null".
Observed on a collections bay: the controller-credential entry, which runs
immediately after UDC Data Restore, failed this way while the entry one line
earlier had resolved a W: path successfully one second before.
Restore-UDCData now uses R: and Update-MachineNumber uses N: for the UDC
backup share. Neither letter is referenced anywhere else in the tree; V: was
not an option because Restore-EDncReg and Update-MachineNumber's NTLARS
restore already use it.
The re-mount at GE-Enforce.ps1:239-244 does not cover this. It runs after the
manifest loop and blames idle SMB timeout, but the whole cycle took one
second, so timeout was never the cause.
Adds os= and boot= to the POST log line so report-asset-*.log shows whether
the PC actually grabbed the OS version and LastBootUpTime (uptime source).
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
- collect logged-in user (console user via Win32_ComputerSystem, bare
username), pc-type (C:\Enrollment\pc-type.txt), make/model, OS version
(caption + DisplayVersion + build), last boot time (for uptime)
- report BOTH corp and controller NICs (physical only), each with MAC,
tagged IsMachineNetwork; was corp-only before
- machine-number sourcing adds C:\Enrollment\cmm\cmmid.txt (CMM bay id)
and skips the 9999 placeholder everywhere
- intended to run from common\ (every pc-type), not collections-only;
api.asp patch-style update keeps it from clobbering other types
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
- lib Install-FromManifest 2.5->2.6: add _CmmVersion per-entry filter (reads
C:\Enrollment\cmm\version.txt). Lifted the version gate out of 09-Setup-CMM
into the shared lib so imaging and GE-Enforce apply it identically and cannot
drift (root cause of PC-DMIS 2016 installing on every CMM).
- Install-goCMMSettings: canonicalize the part-group share host to the FQDN in
both the registry and ApplicationSettings.xml. Handles bare \\tsgwp00525\ and
the legacy rd.ds.ge.com domain; idempotent. VM-tested.
- Report-AssetToShopDB: resolve the machine number eDNC registry first, then fall
back to C:\Enrollment\machine-number.txt (matches the lib resolution order) so
a freshly imaged PC still reports its number for the PC-machine relationship.
- Add Update-CMMEnforcer.ps1/.bat: update one CMM's local lib to the gated
version and self-heal its PC-DMIS version.
- Add Debug-ShopDBReporting.ps1/.bat: one-shot reporter triage (preconditions,
client log, live test POST, verdict).
- Add Verify-And-Heal-Staging.ps1/.bat: post-boot check that every imaging
payload arrived and re-pull anything missing from the share, including the CMM
bundle and the selected bay's backup (the payload that times out in WinPE).
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Replace per-type eDNC_6-4-5.msi with eDNC-6.4.7.msi (ProductVersion
6.4.7.0) in collections, nocollections, heattreat, and partmarker.
01-eDNC.ps1 already prefers the single shared installer at
C:\PreInstall\installers\dnc (6.4.7); aligning the per-type fallback
means an empty shared dir can no longer install a stale 6.4.5. All DNC
types now resolve to 6.4.7 on either path.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
01-eDNC.ps1 (all 4 DNC types) now installs eDNC from the shared pre-install copy
staged by startnet.cmd to C:\PreInstall\installers\dnc - one source of truth
(currently 6.4.7) instead of a per-type bundled msi. Falls back to the per-type
eDNC\ folder when the shared copy is absent (older images). eMxInfo.txt, the
x86->64 mirror, and Site/MachineNo registry steps are unchanged.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Adds Report-AssetToShopDB.ps1 (Type=PS1, DetectionMethod=Always manifest entry)
for collections PCs. Reads hostname, BIOS serial, eDNC MachineNo and the corp
NIC IPv4 (filtered to WJ corp ranges, controller NIC dropped) and POSTs
action=updateCompleteAsset to ShopDB api.asp, which upserts the machine, stores
the IP, and links the PC to its machine-number equipment. manifest-entry-report-asset.json
is the snippet to merge into the SFLD share collections manifest (+ stage the
script under apps/). Note: relies on the ShopDB api.asp LogToFile Err-leak fix
(separate shopdb repo commit) to create the relationship reliably.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
09-Setup-CMM: add Step 2.6 that launches each installed PC-DMIS
version once as admin before the PPKG locks the machine down. Also
adds PC-DMIS 2026.1 to the ACL directory list.
Controller credential: cmdkey /add under SYSTEM stored creds in the
wrong vault. Switch to a Register script (MarkerFile detection, runs
once) that creates an AtLogOn scheduled task under BUILTIN\Users so
cmdkey runs in the ShopFloor user's session.
IE compat: update test matrix hash for the new site list that adds
wjfms3.apps.wlm.geaerospace.net.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
OLD design: a single 'Check Machine Number' scheduled task ran as the
logged-in user (BUILTIN\Users, Limited) on AtLogOn. It both showed the
InputBox AND tried to update HKLM\SOFTWARE\WOW6432Node\GE Aircraft
Engines\DNC\General + C:\ProgramData\UDC\udc_settings.json. To make
those non-admin writes possible, 02-MachineNumberACLs.ps1 pre-granted
BUILTIN\Users SetValue + Modify on those targets during imaging.
Three problems with that:
1. SECURITY: any logged-in user could overwrite the machine-identity
reg key.
2. FRAGILE: ACL grants raced with eDNC install timing on some bays
(eDNC reg key didn't exist yet when 02-MachineNumberACLs ran;
OpenSubKey returned null, ACL silently skipped, Check-MachineNumber
later failed with PermissionDenied).
3. SILENT-SUCCESS BUG: Update-MachineNumber's Set-ItemProperty calls
lacked -ErrorAction Stop. PermissionDenied is a non-terminating
error in PS5.1, so the try/catch never fired. The script set
$out.EdncUpdated=$true anyway and the dialog reported success
while the reg value stayed at 9999. WJF capture log on FGY07FZ3
shows this exact pattern.
NEW design - two scheduled tasks split by responsibility:
- "Prompt Machine Number" : AtLogOn trigger, BUILTIN\Users (Limited).
Reads current values (read-only). If 9999, shows InputBox. Writes
typed number to C:\Logs\SFLD\machine-number-request.txt. Triggers
SYSTEM Apply via schtasks /run. Polls for result JSON (60s timeout).
Shows result MessageBox with TopMost so it isn't hidden behind
other windows.
- "Apply Machine Number" : on-demand, SYSTEM (Highest). Reads the
request file, calls Update-MachineNumber (full HKLM + ProgramData
access from SYSTEM context). Pulls per-machine NTLARS .reg + UDC
settings JSON + UDC live data from the SFLD share if site-config
has share paths. Writes result JSON. Removes request file.
Unregisters the Prompt task on full success (Prompt itself can't
self-unregister - Limited users can't delete a SYSTEM-owned task).
- Default task SDDL only allows Admins + SYSTEM to read/run a
SYSTEM-owned task. Added BUILTIN\Users GR+GX ACE via COM
SetSecurityDescriptor so the Limited Prompt task can schtasks /run
Apply on demand. They can read + execute it; not modify or delete.
- Update-MachineNumber.ps1 writes now have -ErrorAction Stop so
PermissionDenied actually fires the catch block instead of being
swallowed.
- 02-MachineNumberACLs.ps1 gutted to a no-op (left in place for
Stage-Dispatcher discovery; no longer grants the ACLs). Old bays'
existing grants are harmless since SYSTEM ignores them.
- Register-CheckMachineNumberTask.ps1 now installs both tasks AND
unregisters the legacy 'Check Machine Number' task name on
re-imaging. Run-ShopfloorSetup.ps1's $skipInBaseline list now
includes Prompt-MachineNumber.ps1 + Apply-MachineNumber.ps1 so
they aren't auto-run during the baseline pass (only via the
scheduled tasks).
Smoke tested end-to-end on win11 VM with ShopFloor (Limited) logging in
interactively: AtLogOn trigger fired Prompt, dialog rendered, tech
typed 7777, schtasks /run succeeded (the SDDL fix lets Limited users
trigger SYSTEM tasks), Apply ran as SYSTEM, eDNC reg + machine-number.txt
both updated to 7777, result MessageBox shown, Prompt task auto-
unregistered by Apply's cleanup step. No ACL grants needed on any user.
Apply also re-tested with -ErrorAction Stop confirming non-terminating
PermissionDenied now properly throws into the catch + populates Errors[]
+ flips $out.EdncUpdated to false - so any future write failures will
report honestly instead of silently claiming success.
- Drop -Physical + MediaType filter from Get-NetAdapter; some OEM driver
stacks report HardwareInterface=False or localize MediaType, hiding the
Realtek controller NIC from the previous query.
- Refine corp-vs-controller classification: skip only if a gateway is set
AND it's not 192.168.1.x, OR if the IP looks corp (10.x / 172.16-31.x).
Keep candidates that are unconfigured, link-local, or 192.168.x.
- Disable DHCP in both PersistentStore and ActiveStore before New-NetIPAddress
to avoid "Inconsistent parameters PolicyStore PersistentStore and Dhcp
enabled" failures.
- Fall back to netsh interface ip set address when the PS cmdlets still
fight each other; netsh writes both stores cleanly.
04-SetControllerNicIP.ps1 (imaging-time, runs once via Run-ShopfloorSetup):
- Finds the Realtek physical Ethernet adapter (controller NIC on every
collections bay; corp LAN is Intel)
- Skips any candidate with a DHCP default gateway (that one is the corp
LAN, not the controller)
- Skips any candidate already on 192.168.1.2
- Sets static 192.168.1.2/24, no gateway, clears DNS - matches the
manual procedure documented in post-deploy-debug-flowchart.md section 2B
- Refuses to guess when multiple Realtek NICs remain ambiguous
- Imaging-time only, not enforced via GE-Enforce so the tech can override
on a specific bay if needed without the drift-catcher reverting
Set-ControllerCredential.ps1 + manifest-entry-controller-credential.json:
- Break-glass cmdkey /add for the controller SMB share (\\192.168.1.1\md1
used by DNC). Scoped to the 12 Okuma LOC650 machine numbers (3201-3212).
- Manifest entry is detection-less so it runs every enforce cycle if the
script is armed (.ps1 extension); disarmed by default (.ps1.bak on the
share) so a coach can rename when a bay loses its credential without
the enforcer overwriting per-bay deviations between events.
- Smoke-tested end-to-end on win11 VM via QGA: SYSTEM context cmdkey /add
succeeds, cmdkey /list shows the entry. DNC service runs as LocalSystem
so SYSTEM vault is the right target.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Single-site bay-stuck issue at WJ: GE Intune Report IP script filters
Get-NetIPAddress on StartsWith("10.") and posts everything matching
to the GE Tines webhook. Bays at WJ get the PXE LAN 10.9.100.x IP
captured and reported -> GE backend tags bays as on a non-corp 10.x
subnet -> dynamic group eligibility for SFLD policy never matches.
Other GE sites work because their PXE LANs aren't on 10.x at all.
Renumber PXE LAN to RFC1918 172.16.9.0/24 so the GE filter naturally
skips wired PXE addresses without any disable-NIC dance.
Server-side already in flight (netplan dual-bound, dnsmasq scope +
boot URL repointed, blancco preferences + grub.cfg + iPXE GetPxeScript
all sed'd to 172.16.9.1). This commit is the playbook / scripts /
docs side: 109 hits across 35 files sed'd in one shot.
After this lands + boot.wim is rebuilt + bays renumber off DHCP,
the 10.9.100.1 binding will be dropped from netplan as the final
cleanup step.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Tech catches a PC imaged with a wrong machine number. Previously the
share restore (NTLARS .reg + UDC settings + UDC live data) only fired
on the placeholder->real transition, so a real->real change rewrote
only UDC JSON, eDNC reg, and MTConnect Devices.xml - leaving the wrong
NTLARS config in place.
Update-MachineNumber.ps1: replace the placeholder-only guard with an
any-change guard so the share restore block fires on reassign too.
The existing one-shot migrated/ consumption keeps live-data restore
idempotent. Also writes C:\Enrollment\machine-number.txt to keep
imaging-time scripts in sync.
Set-MachineNumber.ps1 (both collections + nocollections): show a
confirmation dialog when reassigning between two real numbers, naming
old/new and listing what gets pulled. Audit each call to
C:\Logs\Shopfloor\reassign.log.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Bundles drift left uncommitted from prior sessions and the UDC matrix
verify entry added today.
Drift items (all per session-progress.md, completed in earlier sessions
but never staged):
- playbook/check-bios.cmd (deleted, moved to BIOS/check-bios.cmd)
- playbook/migrate-to-wifi.ps1 (made no-op 2026-04-24 after the dnsmasq
no-gateway fix removed the wired-NIC race that motivated it)
- playbook/preinstall/oracle/Install-Oracle11r2.cmd (post-OUI .ora copy
added 2026-04-24)
- playbook/preinstall/oracle/tnsnames.ora (live tnsnames, 469 KB,
deployed alongside the wrapper 2026-04-24)
- playbook/pxe_server_setup.yml (dnsmasq dhcp-option=3,6 commented,
Oracle .ora deploy task added 2026-04-24)
- playbook/shopfloor-setup/BIOS/{check-bios.cmd, models.txt} (BIOS
detection refinements)
- playbook/shopfloor-setup/Shopfloor/Force-Lockdown.bat
- playbook/shopfloor-setup/Shopfloor/Monitor-IntuneProgress.ps1
- playbook/shopfloor-setup/Shopfloor/SetShopfloorAutoLogon.bat (new)
- playbook/shopfloor-setup/Shopfloor/09-Install-PrinterInstallerMap.ps1
(new, places PrinterInstallerMap.exe + Public Desktop shortcut at
imaging time; manifest entry self-heals on tamper)
- playbook/shopfloor-setup/Shopfloor/lib/Show-IntuneDeviceQR.ps1 (new,
standalone QR rendering for site that wanted just that piece)
- playbook/shopfloor-setup/gea-shopfloor-collections/{Install-eMxInfo.cmd.template,
Restore-UDCData.ps1} (these were uncommitted in pre-rename Standard/;
git mv didn't catch them because they were untracked at the time)
- docs/shopfloor-machine-imaging-guide.md (operator-facing how-to)
Matrix:
- common.test/matrix.json: add UDC verify entry to gea-shopfloor-collections
row. Surfaces UDC silent-install issue (item H pending) instead of
letting it pass silently.
.gitignore:
- PrinterInstallerMap.exe (142 MB) excluded. Track via LFS or stage on
PXE server only - too big for regular git history. Untouched on disk
so existing local copy still works.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Pairs with Phase 1+2 from earlier (alias maps in Install-FromManifest,
GE-Enforce, Get-PCProfile, verify-state). See project-shopfloor-rename-reorg
memory for the plan.
Phase 3 (repo + paths):
- git mv per-PC-type dirs to gea-shopfloor-* names:
Standard -> gea-shopfloor-collections
CMM -> gea-shopfloor-cmm
Keyence -> gea-shopfloor-keyence
Genspect -> gea-shopfloor-genspect
WaxAndTrace -> gea-shopfloor-waxtrace
Display -> gea-shopfloor-display
Lab -> gea-shopfloor-common (folded; Timeclock+Lab merge)
- New gea-shopfloor-nocollections/ (clone of collections sans UDC scripts).
- New gea-shopfloor-heattreat/ (placeholder, README only).
- Move Standard/ntlars-backups/ -> _ntlars-backups/ (per-MN, not per-type).
- Run-ShopfloorSetup.ps1: Resolve-PCTypeDir helper walks alias group when
the on-disk dir for the current pcType is missing. Set-MachineNumber
helper-copy gated on collections|nocollections|legacy Standard-Machine.
- Update-MachineNumber.ps1: pcProfiles lookups try gea-shopfloor-collections
first, fall back to legacy Standard-Machine. PowerShell 5.1 compatible
(no null-coalesce).
Phase 4 (startnet.cmd menu):
- Choice 3 "GEA Shopfloor" now drills into a 9-item sub-menu instead of
going straight to enrollment. Sub-cats:
1. Machine with Collections -> gea-shopfloor-collections
2. Machine without Collections -> gea-shopfloor-nocollections
3. Common (Timeclock, Lab) -> gea-shopfloor-common
4. Keyence -> gea-shopfloor-keyence
5. CMM -> gea-shopfloor-cmm
6. Genspect -> gea-shopfloor-genspect
7. Heattreat -> gea-shopfloor-heattreat
8. Wax and Trace -> gea-shopfloor-waxtrace
9. Display -> gea-shopfloor-display
- Office menu (existing 6-option) follows for every sub-cat.
- Machine number prompt only for collections + nocollections.
- pc-subtype.txt + display-type.txt no longer written. PCTYPE is a
single full string (gea-shopfloor-*); subtype-aware code paths fall
back to empty and resolve via the alias map.
- CMM bootstrap stage gate switched from "%PCTYPE%"=="CMM" to
"%PCTYPE%"=="gea-shopfloor-cmm".
Test harness:
- B-enforce/run.sh PCSUBTYPE default changed from "Machine" to "" so
single-arg invocation matches the new single-string scheme. Two-arg
legacy form ("Standard Machine") still works via aliasing.
- B-enforce/tamper.ps1 alias-aware Test-MatrixEntryMatches mirroring
verify-state.ps1.
Smoke-tested on win11 VM as SYSTEM via qga: B-enforce harness 5-phase
cycle (stage / baseline / tamper / heal / idempotent) passes 10/10
with PCType=gea-shopfloor-collections AND with legacy "Standard Machine"
two-arg form.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>