Commit Graph

14 Commits

Author SHA1 Message Date
cproudlock
6db170bf54 Shell defaults + eDNC reg restore from machine-number backups
- 03-ShellDefaults.ps1: Default-User TaskbarAl=0 (left), HKLM policies to
  hide Start Recommended section, kill Bing web search + suggestions,
  disable Cortana. LTSC-honoured; runs fleet-wide via baseline loop.

- ntlars-backups/: 147 per-machine eDNC registry backups renamed to
  flat <MachineNumber>.reg scheme. Historical off-by-one entries from
  the original dump rewritten to match CSV-target MachineNo.

- Standard/03-RestoreEDncConfig.ps1: at imaging time, if tech typed a
  real machine number at PXE (not 9999), import <num>.reg from the local
  staged copy. Restores eFocas IP, PPDCS serial, Hssb relays -- not just
  the bare MachineNo. Skipped on Timeclock / 9999 / missing backup.

- Update-MachineNumber.ps1: when tech later sets a real number from 9999,
  pull <num>.reg from tsgwp00525 SFLD share (ntlarsBackupSharePath in
  site-config) and reg-import it before writing the new MachineNo.

- Restore-EDncReg.ps1: shared helper (Mount-SFLDShare + Import-EDncRegBackup)
  used by both callers.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-15 15:42:21 -04:00
cproudlock
855d501fc2 Fix Display sync loop, PPKG deployment, dnsmasq cron, dpkg configure
- Monitor-IntuneProgress: Display PCs skip DSC phases entirely (no SAS
  token, no DSCInstall.log), complete after Phase 1 identity. Renderer
  hides Phase 2-5 for Display type.
- Playbook: deploy PPKG files and run-enrollment.ps1 from USB to
  enrollment share. Bump dnsmasq restart cron from 15s to 30s.
- build-usb.sh: copy enrollment/ directory (PPKGs) onto USB if present.
- user-data: add dpkg --configure -a after offline .deb install to fix
  packages left in unconfigured state (cron, systemd-timesyncd).

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-13 14:27:21 -04:00
cproudlock
f3211dfd29 CMM test iteration: desktop shortcuts, rename to 09-Setup-*, defer NIC re-enable
Rolls up everything from the CMM imaging test iteration tonight. No
single concern - several small, related polish items on the option-3
patched-MSI pipeline and the shopfloor-setup / sync_intune handoff.

- Rename all type-specific "01-Setup-<Type>.ps1" scripts to
  "09-Setup-<Type>.ps1" across CMM, Display, Genspect, Keyence, Lab,
  and WaxAndTrace. The "01-" prefix implied the script runs first in
  the overall sequence when it actually runs between baseline (00, 04)
  and finalization (06, 07). Logs now read "Running CMM setup:
  09-Setup-CMM.ps1" which matches the real position. Standard/
  01-eDNC.ps1 + 02-MachineNumberACLs.ps1 left alone - those digits
  represent real within-type ordering.
- playbook/shopfloor-setup/site-config.json CMM profile updates:
  - startupItems = [] (empty). Previously had WJ Shopfloor auto-launch
    which the user does not want on CMM workstations. Now relies on
    the Get-ProfileValue empty-array fix to not fall through to site
    defaults.
  - desktopApps + taskbarPins gain entries for PC-DMIS 2016, PC-DMIS
    2019 R2, CLM Admin, and goCMM so 06-OrganizeDesktop Phase 2
    materializes them into C:\\Users\\Public\\Desktop\\Shopfloor Tools\\
    and 07-TaskbarLayout pins them. goCMM is under C:\\Program Files
    (x86)\\General Electric\\goCMM\\ (GE product, not Hexagon).
- playbook/shopfloor-setup/Run-ShopfloorSetup.ps1: remove the blocking
  "UNPLUG ethernet cable, press any key" prompt + the interactive
  wired-NIC re-enable. The whole prompt block was a hard blocker on
  the imaging chain that required a human to walk to each PC.
- playbook/shopfloor-setup/Shopfloor/lib/Monitor-IntuneProgress.ps1:
  re-enable wired NICs unconditionally at the top of the transcript.
  This is the new home for the re-enable that used to live behind the
  prompt in Run-ShopfloorSetup. By the time sync_intune fires (after
  PPKG reboot + auto-login + Stage-Dispatcher), the tech has had
  minutes of wall-clock time to physically rewire from PXE to
  production without us blocking on a keypress. Tower case is a
  no-op because migrate-to-wifi.ps1 already left wired enabled.
- Internal comment updates in 09-Setup-CMM.ps1, cmm-manifest.json,
  Install-FromManifest.ps1, and startnet.cmd (+ startnet-template)
  to reflect the new filename.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-11 21:03:09 -04:00
cproudlock
ee7d3bad66 Shopfloor imaging: CMM type, Configure-PC override fix, serial drivers
- CMM imaging pipeline: WinPE-staged bootstrap + on-logon enforcer
  against tsgwp00525 share, manifest-driven installer runner shared via
  Install-FromManifest.ps1. Installs PC-DMIS 2016/2019 R2, CLM 1.8,
  goCMM; enables .NET 3.5 prereq; registers GE CMM Enforce logon task
  for ongoing version enforcement.
- Shopfloor serial drivers: StarTech PCIe serial + Prolific PL2303
  USB-to-serial via Install-Drivers.cmd wrapper calling pnputil
  /add-driver /subdirs /install. Scoped to Standard PCs.
- OpenText extended to CMM/Keyence/Genspect/WaxAndTrace via
  preinstall.json PCTypes; Defect Tracker added to CMM profile
  desktopApps + taskbarPins.
- Configure-PC startup-item toggle now persists across the logon
  sweep via C:\\ProgramData\\GE\\Shopfloor\\startup-overrides.json;
  06-OrganizeDesktop Phase 3 respects suppressed items.
- Get-ProfileValue helper added to Shopfloor/lib/Get-PCProfile.ps1;
  distinguishes explicit empty array from missing key (fixes Lab
  getting Plant Apps in startup because empty array was falsy).
- 06-OrganizeDesktop gains transcript logging at C:\\Logs\\SFLD\\
  06-OrganizeDesktop.log and now deletes the stale Shopfloor Intune
  Sync task when C:\\Enrollment\\sync-complete.txt is present (task
  was registered with Limited principal and couldn't self-unregister).
- startnet.cmd CMM xcopy block (gated on pc-type=CMM) stages the
  bundle to W:\\CMM-Install during WinPE.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-11 12:58:47 -04:00
cproudlock
3d5814cd7c Use marker file instead of task unregister for sync completion
BUILTIN\Users (Limited RunLevel) can't delete scheduled tasks, so
Unregister-ScheduledTask failed silently and the sync task kept firing
at every logon even after completion.

Fix: write C:\Enrollment\sync-complete.txt on completion. At script
startup in -AsTask mode, check for the marker and exit immediately if
found. The task stays in Task Scheduler but does nothing -- fires at
logon, sees marker, exits in under a second. No visible window.

Manual sync_intune.bat runs (no -AsTask) ignore the marker and always
show the full status display for inventory QR code purposes.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-10 15:09:11 -04:00
cproudlock
07ebe819bd Auto-apply startup items from profile, Configure-PC -MachineNumberOnly
Three changes to eliminate the redundant startup-item picker during
the imaging chain:

06-OrganizeDesktop.ps1 - new Phase 3: auto-apply startup items
  Reads pcProfile.startupItems (or site-wide default) and creates
  .lnk files in AllUsers Startup folder. Supports exe, existing, and
  url types (same as Configure-PC). Idempotent - skips items that
  already exist so manual changes aren't overwritten. Runs during
  shopfloor setup finalization, so the tech doesn't need to select
  startup items again.

Configure-PC.ps1 - new -MachineNumberOnly switch
  When set, skips the entire startup-items section and only shows the
  machine number prompt (if UDC/eDNC at 9999). Used by sync_intune
  -AsTask after completion. Full startup picker still available when
  the tech opens Configure-PC.bat manually from the desktop.

Monitor-IntuneProgress.ps1 - simplified -AsTask completion
  After post-reboot DSC complete: unregisters task, launches
  Configure-PC -MachineNumberOnly, exits. Tech uses sync_intune.bat
  on the desktop to see QR code for inventory purposes.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-10 14:54:31 -04:00
cproudlock
15f67063bd Refresh QR code after AAD join detected
The QR code text was built once at script startup. If the device wasn't
AAD-joined yet, it showed "Device not yet Azure AD joined" forever -
even after Phase 1 checks passed. Now regenerates Build-QRCodeText
when Phase1.AzureAdJoined transitions to true.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-10 14:38:15 -04:00
cproudlock
c06310f5bd Replace all Unicode characters with ASCII in playbook scripts
Em dashes (U+2014) and arrows (U+2192) break PowerShell 5.1 on
Windows when the file has no UTF-8 BOM -- byte 0x94 gets read as
a right double quote in Windows-1252, silently closing strings
mid-parse. This caused run-enrollment.ps1 to fail on PXE-imaged
machines with "string is missing the terminator" at line 113.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-10 13:23:11 -04:00
cproudlock
7c8eb6899d Shared machine-number helper, site-config for OpenText + PreInstall, placeholder type dirs
Three optimization batches from the pipeline audit:

1. Shared Update-MachineNumber.ps1 helper (lib/)
   Extracts duplicated machine-number update logic from Configure-PC.ps1,
   Check-MachineNumber.ps1, and Set-MachineNumber.ps1 into a shared
   dot-sourceable helper at Shopfloor/lib/Update-MachineNumber.ps1.

   Exports:
     Get-CurrentMachineNumber → @{ Udc = $string; Ednc = $string }
     Update-MachineNumber -NewNumber <n> [-Site <s>] → @{ UdcUpdated; EdncUpdated; Errors }

   All three consumers now dot-source the helper instead of duplicating
   ~50 lines each. Set-MachineNumber.ps1 also migrated from inline
   Get-SiteConfig to dot-sourcing Get-PCProfile.ps1 for consistency.

2. Site-config integration for remaining scripts
   Setup-OpenText.ps1: exclude lists (profiles + shortcuts) now read from
     site-config.json opentext section, falling back to West Jefferson
     defaults. Inline Get-SiteConfig since the script runs from
     C:\PreInstall\installers\opentext\ (can't dot-source Get-PCProfile).

   00-PreInstall-MachineApps.ps1: after parsing preinstall.json, scans
     InstallArgs for "West Jefferson" and replaces with site-config
     siteName if different. Inline Get-SiteConfig for same reason.

3. Placeholder type-specific directories
   Created skeleton 01-Setup-*.ps1 scripts for all PC types so the
   directory structure is in place and Run-ShopfloorSetup's type-specific
   loop has something to iterate over:
     Genspect/01-Setup-Genspect.ps1
     Keyence/01-Setup-Keyence.ps1
     WaxAndTrace/01-Setup-WaxAndTrace.ps1
     Lab/01-Setup-Lab.ps1
   Each logs a "no type-specific apps configured yet" banner and exits.
   Fill in app installs when details are finalized; for share-based
   installs, copy the CMM/01-Setup-CMM.ps1 pattern.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-10 11:44:10 -04:00
cproudlock
ed803539e0 PC profiles: per-type/sub-type config + Standard Timeclock/Machine menu
Adds a pcProfiles section to site-config.json that lets each PC type (and
optional sub-type) override startupItems, taskbarPins, and desktopApps.
Scripts resolve: pcProfile > site-wide default > hardcoded fallback.

New shared helper: Shopfloor/lib/Get-PCProfile.ps1
  Dot-sourced by consuming scripts. Reads pc-type.txt + pc-subtype.txt,
  builds a profile key (e.g. "Standard-Machine"), and looks it up in
  site-config.json pcProfiles. Exports $siteConfig, $pcType, $pcSubtype,
  $profileKey, $pcProfile for the caller to use.

  Replaces the inline Get-SiteConfig function that was copy-pasted into
  each script. Scripts now do:
    . "$PSScriptRoot\lib\Get-PCProfile.ps1"
  instead of duplicating the loader.

startnet.cmd changes:
  - Added Lab as PC type option (7)
  - Standard now has a sub-type menu: Timeclock / Machine
  - Display sub-type menu also writes PCSUBTYPE for consistency
  - pc-subtype.txt written alongside pc-type.txt when sub-type selected
  - site-config.json copied from enrollment share to W:\Enrollment\

site-config.json v2.0:
  - New pcProfiles section with profiles for:
    Standard-Timeclock, Standard-Machine, CMM, Genspect, Keyence,
    WaxAndTrace, Lab, Display-Lobby, Display-Dashboard
  - CMM/Genspect/Keyence/WaxAndTrace profiles have TODO comments for
    type-specific apps (placeholder with WJ Shopfloor baseline only)
  - Lab/Display profiles have empty startupItems and desktopApps
  - Top-level startupItems/taskbarPins/desktopApps remain as site-wide
    defaults (used when no profile matches)

Updated scripts:
  06-OrganizeDesktop.ps1 - desktopApps from profile > site > hardcoded
  07-TaskbarLayout.ps1   - taskbarPins from profile > site > hardcoded
  08-EdgeDefaultBrowser.ps1 - uses shared profile loader
  Configure-PC.ps1       - startupItems from profile > site > hardcoded

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-10 11:19:51 -04:00
cproudlock
b13e34c05a Imaging chain: Stage-Dispatcher + PPKG reboot + unattended sync_intune
Replaces the single-session "cancel PPKG reboot and cram everything into
one autologon" flow with a staged chain where each reboot advances to the
next step automatically. The technician touches the keyboard 3 times total
(UNPLUG prompt, Y to reboot, Configure-PC selections).

New Stage-Dispatcher.ps1:
  Reads C:\Enrollment\setup-stage.txt and chains through:
    shopfloor-setup -> sync-intune -> configure-pc
  Each stage re-registers HKLM RunOnce so the dispatcher fires again on
  the next logon. Stage file is deleted when the chain completes.
  Transcript logged to C:\Logs\SFLD\stage-dispatcher.log.

  Stage "shopfloor-setup": runs Run-ShopfloorSetup.ps1 (which reboots via
    shutdown /r /t 10). Dispatcher advances stage to sync-intune in the
    ~10 second window before the machine goes down, re-registers RunOnce.

  Stage "sync-intune": launches Monitor-IntuneProgress.ps1 -Unattended.
    Exit 2 (pre-reboot done, user confirmed): dispatcher re-registers
    RunOnce and initiates shutdown /r /t 5. Stage stays at sync-intune so
    the monitor picks up post-reboot state on next boot.
    Exit 0 (post-reboot install complete): dispatcher chains directly to
    Configure-PC.ps1 in the same session, then deletes the stage file.

  Stage "configure-pc": runs Configure-PC.ps1 and deletes the stage file.
    Fallback entry point if the post-reboot chain was interrupted.

Modified run-enrollment.ps1:
  Removed the shutdown /a that canceled the PPKG reboot. Instead writes
  setup-stage.txt = "shopfloor-setup" and registers RunOnce for the
  dispatcher. PPKG reboot fires naturally (handles PendingFileRename
  operations like Zscaler rename and PPKG self-cleanup). Now tracked in
  the git repo at playbook/shopfloor-setup/run-enrollment.ps1.

Modified Monitor-IntuneProgress.ps1:
  New -Unattended switch. When set:
    Invoke-SetupComplete exits 0 without waiting for keypress.
    Invoke-RebootPrompt exits 2 without prompting or rebooting (dispatcher
    handles both). Manual sync_intune.bat usage (no flag) unchanged.
  RetriggerMinutes bumped from 3 to 5 (user request).

Modified startnet.cmd:
  Now also copies Stage-Dispatcher.ps1 from the PXE server to
  W:\Enrollment\Stage-Dispatcher.ps1 alongside run-enrollment.ps1.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-10 09:55:00 -04:00
cproudlock
7c26e10f7e sync_intune: gate reboot prompt on Phase 1+2+3 pre-reboot completion
Don't prompt the user to reboot until the enrollment pipeline has
finished its pre-reboot work. Previously Test-RebootState fired as
soon as DSCDeployment.log showed "completed", even if Phase 1 (Identity)
or Phase 2 (SFLD config) checks were still in progress.

Now the reboot prompt requires ALL of these to be green in the snapshot:
  Phase 1: AzureAdJoined, IntuneEnrolled, EmTaskExists, PoliciesArriving
  Phase 2: SfldRoot, FunctionOk, SasTokenOk
  Phase 3: DeployLogExists, DeployComplete

This prevents the edge case where DSCDeployment.log completes but the
user reboots before Intune policies have fully landed, which could leave
the post-reboot DSC install phase without the SAS token or function
assignment it needs.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-10 09:31:11 -04:00
cproudlock
c464f45f4f Shopfloor sync_intune + Set-MachineNumber hardening
Long debugging round on the shopfloor test PC with several overlapping
bugs. This commit folds all the fixes together.

sync_intune.bat
- Slim down to an elevation thunk that launches a NEW elevated PS
  window via Start-Process -Verb RunAs (with -NoExit so the window
  doesn't vanish on error). All UI now lives in the PS monitor, not
  mixed into the cmd launcher.
- Goto-based control flow. Earlier version had nested if (...) blocks
  with literal parens inside echo lines (e.g. "wrappers (Install-eDNC,
  ...etc)."); cmd parses if-blocks by counting parens character-by-
  character, so the ")" in "etc)." closed the outer block early and
  the leftover "." threw ". was unexpected at this time.", crashing
  the elevated cmd /c window before pause ran.
- Multi-location Monitor-IntuneProgress.ps1 lookup so the user's
  quick-test workflow (drop both files on the desktop) works without
  manually editing the hardcoded path. Lookup order:
    1. %~dp0lib\Monitor-IntuneProgress.ps1
    2. %~dp0Monitor-IntuneProgress.ps1
    3. C:\Users\SupportUser\Desktop\Monitor-IntuneProgress.ps1
    4. C:\Enrollment\shopfloor-setup\Shopfloor\lib\Monitor-IntuneProgress.ps1
- Prints "Launching: <path>" as its first line so you can see which
  copy it actually loaded. This caught a bug where a stale desktop
  copy was shadowing the canonical file via fallback #2.

Set-MachineNumber.bat
- Same multi-location lookup pattern. Old version used
  %~dp0Set-MachineNumber.ps1 and bombed when the bat was copied to
  the desktop without its .ps1 sibling.
- Goto-based dispatch, no nested parens, for the same parser reason.

Monitor-IntuneProgress.ps1
- Start-Transcript at the top, writing to C:\Logs\SFLD\ (falls back
  to %TEMP% if C:\Logs\SFLD isn't writable yet) with a startup banner
  including a timestamp. Every run leaves a captured trace.
- Main polling loop wrapped in try/catch/finally. Unhandled exceptions
  print a red report with type, message, position, and stack trace,
  then block on Wait-ForAnyKey so the window can't auto-close on a
  silent crash.
- Console window resize at startup via $Host.UI.RawUI.WindowSize /
  BufferSize, wrapped in try/catch (Windows Terminal ignores it, but
  classic conhost honors it).
- Clear-KeyBuffer / Read-SingleKey / Wait-ForAnyKey helpers. Drain any
  buffered keystrokes from the polling loop before each prompt so an
  accidental keypress can't satisfy a pause prematurely.
- Invoke-SetupComplete / Invoke-RebootPrompt final-state handlers.
  The REBOOT REQUIRED branch now shows a yellow 3-line header, a
  four-line explanation, and a cyan "Press Y to reboot now, or N to
  cancel:" prompt via Read-SingleKey @('Y','N'). Y triggers
  Restart-Computer -Force (with shutdown.exe fallback), N falls
  through to Wait-ForAnyKey.
- Display order: status table FIRST, QR LAST. The cursor ends below
  the QR so the viewport always follows it - keeps the QR on screen
  regardless of window height. Works on both classic conhost and
  Windows Terminal (neither reliably honors programmatic resize).
- Half-block QR renderer: walks QRCoder's ModuleMatrix directly and
  emits U+2580 / U+2584 / U+2588 / space, one output line per two
  matrix rows. Halves the rendered height vs AsciiQRCode full-block.
  Quiet zone added manually via $pad=4 since QRCoder's ModuleMatrix
  doesn't include one. Trade-off: may not be perfectly square on all
  fonts, but the user accepted that for the smaller footprint after
  multiple iterations comparing full-block vs half-block vs PNG popup.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-09 13:30:12 -04:00
cproudlock
a33a115394 Move Monitor-IntuneProgress.ps1 to lib/ - it was hanging the dispatcher
Run-ShopfloorSetup.ps1 line 46-47 does:

  Get-ChildItem -Path $baselineDir -Filter "*.ps1" -File | Sort-Object Name
  foreach ($script in $scripts) { & $script.FullName }

This picks up EVERY *.ps1 in Shopfloor\ and runs it as a baseline
script. Last commit (66d13d8) put Monitor-IntuneProgress.ps1 in that
same directory, which means the dispatcher was running it as the LAST
baseline script (M sorts after 00/04/05). The monitor is an infinite
poll loop that never returns until the SFLD lifecycle is complete -
so the dispatcher hung there forever, and Standard\01-eDNC.ps1 and
Standard\Set-MachineNumber.ps1 never ran.

Symptoms in the test run:
  - 00-PreInstall-MachineApps.ps1 ran (10 installed, 1 OpenText fail)
  - 04-NetworkAndWinRM.ps1 ran silently
  - 05-OfficeShortcuts.ps1 ran silently
  - Monitor-IntuneProgress.ps1 started (Clear-Host + status table) and
    hung in its main loop
  - eDNC + Set-MachineNumber never ran

Fix: move Monitor-IntuneProgress.ps1 into Shopfloor\lib\ so the
dispatcher's non-recursive Get-ChildItem doesn't see it. Update
sync_intune.bat's MONITOR path to the new location, and add a
comment explaining WHY the monitor lives under lib\ to prevent this
mistake from being repeated.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>