Adds a CMM-style logon enforcer so VR-6000 updates push fleet-wide
without re-imaging.
- keyence-manifest.json: declares VR-6000 MSI (ProductCode-keyed) and
KEYENCE VR USB driver (pnputil-keyed). Single source of truth for
both imaging-time and ongoing-enforcement paths.
- lib/Install-FromManifest.ps1: forked from CMM/lib; adds DetectionMethod
"pnputil" (regex-matches `pnputil /enum-drivers` output) and Type
"INF" (invokes `pnputil /add-driver /install`). Everything else
unchanged so CMM-style error parsing + MSI log scanning carry over.
- Keyence-Enforce.ps1: forked from CMM-Enforce.ps1. SYSTEM scheduled
task, logon trigger, mounts tsgwp00525 SFLD share with creds from
HKLM:\SOFTWARE\GE\SFLD\Credentials (provisioned by Azure DSC),
hands off to Install-FromManifest against the share manifest.
- 09-Setup-Keyence.ps1: rewritten around the manifest. Runs
Install-FromManifest at imaging time, stages runtime scripts to
C:\Program Files\GE\Keyence, registers "GE Keyence Enforce"
scheduled task. Idempotent.
- site-config.json: add keyenceSharePath to the Keyence profile
pointing at \\tsgwp00525\shared\dt\shopfloor\keyence\machineapps.
To push a new VR-6000 version: drop the new MSI + updated manifest on
the tsgwp00525 share, every Keyence PC upgrades on next logon.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
- shopfloor-setup/Keyence/09-Setup-Keyence.ps1: populate placeholder with
MSI install via msiexec and driver install via pnputil. Idempotent on
ProductCode {058E7194-...} and DriverStore entry. Logs to C:\Logs\Keyence\.
- shopfloor-setup/Keyence/installers/VR-6000 Series Software.msi: main
product (1.7 MB; pulled from Keyence6000.exe Inno wrapper's Windows
Installer cache, built with InstallShield 2019).
- shopfloor-setup/Keyence/drivers/: KEYENCE VR Series USB driver
package (.inf + .cat + Wdf/WinUsb co-installers). 2.7 MB, pulled from
DriverStore\FileRepository\keyence_vr_series.inf_amd64_b5e5eb0924d7b4ce.
- preinstall.json: add VC++ 2013 x64 Min + Add entries (PCTypes: ["*"])
as prereqs for VR-6000. GUIDs {A749D8E6-B613-...} and {929FBD26-9020-...}.
Staging footprint for non-Keyence PCs is unchanged (the 4.4 MB Keyence
payload lives under shopfloor-setup/Keyence/ which startnet.cmd only
xcopies for PCTYPE=Keyence). Rollout still requires dropping the two
VC++ 2013 x64 MSIs into \$PXE_IMAGES_DIR/dependencies/vcredist/2013-x64-{min,add}/
on the workstation running sync-preinstall.sh.
Rationale for bundling the MSI + driver locally rather than running
Keyence6000.exe: the Inno wrapper calls an InstallShield child (Setup.exe)
without silent flags, which hangs indefinitely in session 0 during
automated imaging. msiexec + pnputil from the extracted bundle runs
fully non-interactive.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Rolls up everything from the CMM imaging test iteration tonight. No
single concern - several small, related polish items on the option-3
patched-MSI pipeline and the shopfloor-setup / sync_intune handoff.
- Rename all type-specific "01-Setup-<Type>.ps1" scripts to
"09-Setup-<Type>.ps1" across CMM, Display, Genspect, Keyence, Lab,
and WaxAndTrace. The "01-" prefix implied the script runs first in
the overall sequence when it actually runs between baseline (00, 04)
and finalization (06, 07). Logs now read "Running CMM setup:
09-Setup-CMM.ps1" which matches the real position. Standard/
01-eDNC.ps1 + 02-MachineNumberACLs.ps1 left alone - those digits
represent real within-type ordering.
- playbook/shopfloor-setup/site-config.json CMM profile updates:
- startupItems = [] (empty). Previously had WJ Shopfloor auto-launch
which the user does not want on CMM workstations. Now relies on
the Get-ProfileValue empty-array fix to not fall through to site
defaults.
- desktopApps + taskbarPins gain entries for PC-DMIS 2016, PC-DMIS
2019 R2, CLM Admin, and goCMM so 06-OrganizeDesktop Phase 2
materializes them into C:\\Users\\Public\\Desktop\\Shopfloor Tools\\
and 07-TaskbarLayout pins them. goCMM is under C:\\Program Files
(x86)\\General Electric\\goCMM\\ (GE product, not Hexagon).
- playbook/shopfloor-setup/Run-ShopfloorSetup.ps1: remove the blocking
"UNPLUG ethernet cable, press any key" prompt + the interactive
wired-NIC re-enable. The whole prompt block was a hard blocker on
the imaging chain that required a human to walk to each PC.
- playbook/shopfloor-setup/Shopfloor/lib/Monitor-IntuneProgress.ps1:
re-enable wired NICs unconditionally at the top of the transcript.
This is the new home for the re-enable that used to live behind the
prompt in Run-ShopfloorSetup. By the time sync_intune fires (after
PPKG reboot + auto-login + Stage-Dispatcher), the tech has had
minutes of wall-clock time to physically rewire from PXE to
production without us blocking on a keypress. Tower case is a
no-op because migrate-to-wifi.ps1 already left wired enabled.
- Internal comment updates in 09-Setup-CMM.ps1, cmm-manifest.json,
Install-FromManifest.ps1, and startnet.cmd (+ startnet-template)
to reflect the new filename.
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
Three optimization batches from the pipeline audit:
1. Shared Update-MachineNumber.ps1 helper (lib/)
Extracts duplicated machine-number update logic from Configure-PC.ps1,
Check-MachineNumber.ps1, and Set-MachineNumber.ps1 into a shared
dot-sourceable helper at Shopfloor/lib/Update-MachineNumber.ps1.
Exports:
Get-CurrentMachineNumber → @{ Udc = $string; Ednc = $string }
Update-MachineNumber -NewNumber <n> [-Site <s>] → @{ UdcUpdated; EdncUpdated; Errors }
All three consumers now dot-source the helper instead of duplicating
~50 lines each. Set-MachineNumber.ps1 also migrated from inline
Get-SiteConfig to dot-sourcing Get-PCProfile.ps1 for consistency.
2. Site-config integration for remaining scripts
Setup-OpenText.ps1: exclude lists (profiles + shortcuts) now read from
site-config.json opentext section, falling back to West Jefferson
defaults. Inline Get-SiteConfig since the script runs from
C:\PreInstall\installers\opentext\ (can't dot-source Get-PCProfile).
00-PreInstall-MachineApps.ps1: after parsing preinstall.json, scans
InstallArgs for "West Jefferson" and replaces with site-config
siteName if different. Inline Get-SiteConfig for same reason.
3. Placeholder type-specific directories
Created skeleton 01-Setup-*.ps1 scripts for all PC types so the
directory structure is in place and Run-ShopfloorSetup's type-specific
loop has something to iterate over:
Genspect/01-Setup-Genspect.ps1
Keyence/01-Setup-Keyence.ps1
WaxAndTrace/01-Setup-WaxAndTrace.ps1
Lab/01-Setup-Lab.ps1
Each logs a "no type-specific apps configured yet" banner and exits.
Fill in app installs when details are finalized; for share-based
installs, copy the CMM/01-Setup-CMM.ps1 pattern.
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>