Commit Graph

4 Commits

Author SHA1 Message Date
cproudlock
7c8eb6899d Shared machine-number helper, site-config for OpenText + PreInstall, placeholder type dirs
Three optimization batches from the pipeline audit:

1. Shared Update-MachineNumber.ps1 helper (lib/)
   Extracts duplicated machine-number update logic from Configure-PC.ps1,
   Check-MachineNumber.ps1, and Set-MachineNumber.ps1 into a shared
   dot-sourceable helper at Shopfloor/lib/Update-MachineNumber.ps1.

   Exports:
     Get-CurrentMachineNumber → @{ Udc = $string; Ednc = $string }
     Update-MachineNumber -NewNumber <n> [-Site <s>] → @{ UdcUpdated; EdncUpdated; Errors }

   All three consumers now dot-source the helper instead of duplicating
   ~50 lines each. Set-MachineNumber.ps1 also migrated from inline
   Get-SiteConfig to dot-sourcing Get-PCProfile.ps1 for consistency.

2. Site-config integration for remaining scripts
   Setup-OpenText.ps1: exclude lists (profiles + shortcuts) now read from
     site-config.json opentext section, falling back to West Jefferson
     defaults. Inline Get-SiteConfig since the script runs from
     C:\PreInstall\installers\opentext\ (can't dot-source Get-PCProfile).

   00-PreInstall-MachineApps.ps1: after parsing preinstall.json, scans
     InstallArgs for "West Jefferson" and replaces with site-config
     siteName if different. Inline Get-SiteConfig for same reason.

3. Placeholder type-specific directories
   Created skeleton 01-Setup-*.ps1 scripts for all PC types so the
   directory structure is in place and Run-ShopfloorSetup's type-specific
   loop has something to iterate over:
     Genspect/01-Setup-Genspect.ps1
     Keyence/01-Setup-Keyence.ps1
     WaxAndTrace/01-Setup-WaxAndTrace.ps1
     Lab/01-Setup-Lab.ps1
   Each logs a "no type-specific apps configured yet" banner and exits.
   Fill in app installs when details are finalized; for share-based
   installs, copy the CMM/01-Setup-CMM.ps1 pattern.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-10 11:44:10 -04:00
cproudlock
cb2a9d48a1 Shopfloor: Configure-PC tool, machine-number logon prompt, execution order fixes
New tools:

Configure-PC.bat/.ps1 - Interactive desktop tool for SupportUser to
configure a shopfloor PC after imaging. Two sections:
  1. Machine number: if UDC/eDNC are still at placeholder 9999, prompt
     to set the real number right now (updates UDC JSON + eDNC registry,
     restarts UDC.exe with new args).
  2. Auto-startup toggle: pick which apps start at user logon from a
     numbered list (UDC, eDNC, Defect Tracker, WJ Shopfloor, Plant Apps).
     Creates/removes .lnk files in AllUsers Startup folder. Toggle UI
     shows [ON]/[  ] state, safe to re-run anytime. Plant Apps URL
     resolved from .url file at runtime with hardcoded fallback to
     https://mes-wjefferson.apps.lr.geaerospace.net/run/...
  3. Item 6 in the toggle list: register/unregister a "Check Machine
     Number" logon task for standard (non-admin) users. When enabled,
     the task fires at every logon, checks for 9999, pops an InputBox
     if found, updates both apps, then unregisters itself on success.

Check-MachineNumber.ps1 - The logon task script. Runs as the logged-in
user (needs GUI for InputBox), not SYSTEM. Writing to ProgramData + HKLM
is possible because 02-MachineNumberACLs.ps1 pre-grants BUILTIN\Users
write access on the two specific targets during imaging.

02-MachineNumberACLs.ps1 - Standard type-specific script (runs after
01-eDNC.ps1). Opens C:\ProgramData\UDC\udc_settings.json for Users:Modify
and HKLM:\...\GE Aircraft Engines\DNC\General for Users:SetValue. Narrow
scope, not blanket admin.

Execution order fixes in Run-ShopfloorSetup.ps1:

The dispatcher now has two lists: $skipInBaseline (scripts NOT run in the
alphabetical baseline loop) and $runAfterTypeSpecific (scripts run
explicitly after type-specific scripts complete). This fixes the bug where
06/07 ran before 01-eDNC.ps1 installed DnC, so eDNC/NTLARS shortcuts were
silently skipped.

New execution order:
  Baseline: 00-PreInstall, 04-NetworkAndWinRM (skipping 05-08 + tools)
  Type-specific: 01-eDNC, 02-MachineNumberACLs
  Finalization: 06-OrganizeDesktop, 07-TaskbarLayout

06 internally calls 05 (Office shortcuts, Phase 0) and 08 (Edge config,
Phase 4) as sub-phases, so they also benefit from running late. Office
isn't installed until after the first reboot (ppkg streams C2R), so 05
no-ops at imaging time but succeeds when 06's SYSTEM logon task re-runs
it on the second boot. 08 resolves startup-tab URLs from .url files
delivered by DSC (even later); same self-heal via the logon task.

Other fixes in this commit:

- OpenText Setup-OpenText.ps1 Step 4: exclude WJ_Office.lnk, IBM_qks.lnk,
  mmcs.lnk desktop shortcuts (matching the Step 3 .hep profile exclusion
  from the previous commit). Removes stale copies from prior installs.
- 05-OfficeShortcuts.ps1: widened Office detection to 6 path variants
  covering C2R + MSI + Office15/16, with diagnostic output on miss.
- 06-OrganizeDesktop.ps1: removed Phase 3 (desktop-root pin copies for
  eDNC/NTLARS) so shortcuts live in Shopfloor Tools only, not duplicated
  at root. Emptied $keepAtRoot. Added Phase 0 (call 05) and Phase 4
  (call 08). Lazy folder creation + empty-folder cleanup. Scheduled task
  now runs as SYSTEM (was BUILTIN\Users with Limited which failed the
  admin check). Added NTLARS to 07's taskbar pin list.
- 08-EdgeDefaultBrowser.ps1: Plant Apps URL fallback hardcoded from
  device-config.yaml.
- All new scripts have Start-Transcript logging to C:\Logs\SFLD\ with
  timestamps and running-as identity.
- Run-ShopfloorSetup.ps1: Start-Transcript + Stop-Transcript wrapping
  entire dispatcher run, writes to C:\Logs\SFLD\shopfloor-setup.log.
  Configure-PC.bat added to SupportUser desktop copy list.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-10 08:44:28 -04:00
cproudlock
b91a0a4bb7 OpenText: skip WJ_Office, IBM_qks, mmcs .hep profiles
Per West Jefferson request, those three connection profiles aren't used
on shopfloor PCs and just clutter the HostExplorer session picker.
They stay in the bundled source tree (dependencies/opentext/Profile/)
for rollback, we just don't copy them into the runtime destinations.

Implementation:
- New optional Exclude list on $contentMap entries
- Copy-HummingbirdContent filters files through Exclude before copying
- Also removes any stale excluded files from the destination up-front,
  so a PC that got them from an older install gets cleaned up on
  re-deploy (defensive - no production PC has the 15.0.SP1.2 marker
  yet so this won't actually fire in practice)
- NO version bump: 15.0.SP1.2 stays, per explicit request. First
  imaging run picks up the new logic.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-09 14:37:52 -04:00
cproudlock
cd00d6d2e1 OpenText: track Setup-OpenText scripts in repo, opt-in KillAfterDetection
Two related fixes from a debugging round on the test PC:

1. PreInstall runner: detection-during-install kill is now opt-in via
   "KillAfterDetection: true" on JSON entries that need it. Old behavior
   killed any installer as soon as its detection passed - which broke
   Oracle: Oracle creates its registry key partway through install,
   the runner detected it at the 25s poll, killed msiexec mid-install,
   and msiserver was still doing rollback when the next install (VC++
   2008) started - so VC++ 2008 hit ERROR_INSTALL_ALREADY_RUNNING
   (1618). Only UDC needs the detection-kill (its installer spawns a
   hidden WPF window and never exits). Other installers exit cleanly
   on their own and shouldn't be killed.

2. Track Setup-OpenText scripts in git. The bundled OpenText install
   scripts (Setup-OpenText.ps1, Setup-OpenText.cmd, version.txt) live
   at runtime in /home/camp/pxe-images/main/dependencies/opentext/
   alongside the binary install files (~106 MB of MSI/CAB/MSP/MST plus
   profile content). The binaries stay outside git but the script
   logic and version stamp are mirrored into playbook/preinstall/
   opentext/ here so git history captures changes to the install
   logic and version bumps. README.md explains the workflow.

   Latest Setup-OpenText.ps1 includes:
     - $SourceDir default moved into script body (PowerShell evaluates
       param([string]$X = $PSScriptRoot) defaults at parameter-binding
       time, when $PSScriptRoot may not yet be populated, so the
       default came out as empty string and Join-Path crashed)
     - Logging set up FIRST so any startup error gets captured
     - REBOOT=ReallySuppress dropped from both msiexec calls (base MSI
       and SP1 patch) - OpenText installs shell extensions that hook
       explorer.exe, and Restart Manager closes explorer to replace
       the shell DLLs. With REBOOT=ReallySuppress, RM closed explorer
       but interpreted the relaunch as a "reboot action" and refused
       to do it, leaving the user with no desktop. /norestart on its
       own prevents the actual Windows reboot but lets RM cleanly
       close-and-relaunch explorer mid-install.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-09 12:08:07 -04:00