Commit Graph

3 Commits

Author SHA1 Message Date
cproudlock
ce3fbf5a28 sweep: pre-existing drift + matrix UDC entry + ignore 142MB EXE
Bundles drift left uncommitted from prior sessions and the UDC matrix
verify entry added today.

Drift items (all per session-progress.md, completed in earlier sessions
but never staged):

- playbook/check-bios.cmd (deleted, moved to BIOS/check-bios.cmd)
- playbook/migrate-to-wifi.ps1 (made no-op 2026-04-24 after the dnsmasq
  no-gateway fix removed the wired-NIC race that motivated it)
- playbook/preinstall/oracle/Install-Oracle11r2.cmd (post-OUI .ora copy
  added 2026-04-24)
- playbook/preinstall/oracle/tnsnames.ora (live tnsnames, 469 KB,
  deployed alongside the wrapper 2026-04-24)
- playbook/pxe_server_setup.yml (dnsmasq dhcp-option=3,6 commented,
  Oracle .ora deploy task added 2026-04-24)
- playbook/shopfloor-setup/BIOS/{check-bios.cmd, models.txt} (BIOS
  detection refinements)
- playbook/shopfloor-setup/Shopfloor/Force-Lockdown.bat
- playbook/shopfloor-setup/Shopfloor/Monitor-IntuneProgress.ps1
- playbook/shopfloor-setup/Shopfloor/SetShopfloorAutoLogon.bat (new)
- playbook/shopfloor-setup/Shopfloor/09-Install-PrinterInstallerMap.ps1
  (new, places PrinterInstallerMap.exe + Public Desktop shortcut at
  imaging time; manifest entry self-heals on tamper)
- playbook/shopfloor-setup/Shopfloor/lib/Show-IntuneDeviceQR.ps1 (new,
  standalone QR rendering for site that wanted just that piece)
- playbook/shopfloor-setup/gea-shopfloor-collections/{Install-eMxInfo.cmd.template,
  Restore-UDCData.ps1} (these were uncommitted in pre-rename Standard/;
  git mv didn't catch them because they were untracked at the time)
- docs/shopfloor-machine-imaging-guide.md (operator-facing how-to)

Matrix:
- common.test/matrix.json: add UDC verify entry to gea-shopfloor-collections
  row. Surfaces UDC silent-install issue (item H pending) instead of
  letting it pass silently.

.gitignore:
- PrinterInstallerMap.exe (142 MB) excluded. Track via LFS or stage on
  PXE server only - too big for regular git history. Untouched on disk
  so existing local copy still works.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-04 08:49:43 -04:00
cproudlock
a334a56f1e WiFi detection: widen regex to catch hyphen-less 'WiFi' + 802.11
Realtek RTL8852BE describes itself as 'Realtek RTL8852BE WiFi 6 802.11ax
PCIe Adapter' -- no hyphen in 'WiFi' -- which the previous regex
'Wi-Fi|Wireless' rejected. migrate-to-wifi.ps1's gate then exited 0
silently and neither wired NIC got disabled, leaving the imaging chain
running over PXE ethernet for the entire PPKG phase.

New regex Wi-?Fi|Wireless|WLAN|802\.11 covers:
  - Wi-Fi (Intel-style with hyphen)
  - WiFi (Realtek-style without hyphen)
  - Wireless (Intel Wireless-AC, Killer Wireless)
  - WLAN (some Realtek/MediaTek variants)
  - 802.11 (vendor-agnostic spec reference, fallback)

Applied in two callers:
- migrate-to-wifi.ps1 (3 occurrences: gate + disable + re-enable on timeout)
- Monitor-IntuneProgress.ps1 (re-enable wired on sync_intune startup)

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-15 18:03:19 -04:00
cproudlock
c595d3b9cb Shopfloor unattend: move Orders 4/5 logic to external PS1 scripts
FlatUnattendW10-shopfloor.xml was rejected by Windows OOBE with
"the answer file is invalid" after the earlier tower-no-WiFi fix.
Root cause: the inline PowerShell in <CommandLine> for Orders 4 and
5 exceeded the SynchronousCommand CommandLine length limit (~1024
chars) and/or contained characters the unattend schema validator
dislikes.

Fix: move the logic to two external PS1 scripts and shrink both
CommandLine entries to ~85 chars each that just invoke the scripts.

- playbook/wait-for-internet.ps1: 60s interactive prompt ("connect
  production network now"), then poll TCP 443 to login.microsoft-
  online.us for up to 10 min with a hard timeout so the loop always
  exits. Uses Test-NetConnection -Port 443 (not Test-Connection /
  ICMP) because Microsoft 365 edges do not reliably respond to ping.
- playbook/migrate-to-wifi.ps1: Gates the entire wired-disable
  migration on "does a WiFi adapter exist?" If not (tower), the
  script is a no-op. If yes, disable wired / wait for WiFi internet
  with a 5 min timeout / re-enable wired on timeout fallback.
- startnet.cmd stages both new scripts to W:\Enrollment\ next to
  run-enrollment.ps1 during the WinPE phase.
- FlatUnattendW10-shopfloor.xml Orders 4 and 5 shrunk to short
  invocations of C:\Enrollment\wait-for-internet.ps1 and
  C:\Enrollment\migrate-to-wifi.ps1.
- startnet-template.cmd kept in sync.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-11 16:50:58 -04:00