Commit Graph

7 Commits

Author SHA1 Message Date
cproudlock
99e7679e87 HeatTreat: bump DNC app 6.2.1 -> 6.4.9
Replace HeatTreat_6.2.1.msi with HeatTreat_6-4-9.msi (ProductVersion
6.4.9.0, ProductCode {9E603EFE-888A-4E3F-8CF5-7F03B7029919}). The install
script globs HeatTreat*.msi so no logic change; the MSI's NOT
NEWERVERSIONDETECTED LaunchCondition makes 6.2.1 -> 6.4.9 a clean
in-place upgrade. Update version references in 02-Setup-HeatTreat.ps1.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-08 17:09:05 -04:00
cproudlock
1e6603d331 eDNC: default to single shared installer (C:\PreInstall\installers\dnc\eDNC-6.4.7.msi)
01-eDNC.ps1 (all 4 DNC types) now installs eDNC from the shared pre-install copy
staged by startnet.cmd to C:\PreInstall\installers\dnc - one source of truth
(currently 6.4.7) instead of a per-type bundled msi. Falls back to the per-type
eDNC\ folder when the shared copy is absent (older images). eMxInfo.txt, the
x86->64 mirror, and Site/MachineNo registry steps are unchanged.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-05 10:45:24 -04:00
cproudlock
0b116e3ecf HeatTreat: import per-machine DNC .reg by machine number
HeatTreat bays pick a machine number (6601-6604) at imaging; 02-Setup-
HeatTreat now imports the matching reg\<machine-number>.reg after the MSI,
rewritten to WOW6432Node (DNC is 32-bit; reg import does not honor /reg:32),
mirroring the Part Marker WJPRT.reg flow.

- startnet.cmd: route gea-shopfloor-heattreat to the machine-number prompt
  (was defaulting to skip), so machine-number.txt is written for the picker.
- The 6601-6604 .reg files are gitignored (they carry a DNC FtpPasswd
  credential) and deploy via the enrollment share from the working tree.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-01 11:21:58 -04:00
cproudlock
59b1a9fb65 Add Part Marker + HeatTreat shopfloor PC types (eDNC + vendor MSI)
New gea-shopfloor-partmarker type (startnet menu option 10) and fill the
gea-shopfloor-heattreat stub. Both follow the collections eDNC pattern:
01-eDNC.ps1 installs DNC, then a 02-Setup script installs the vendor MSI.

Part Marker (02-Setup-PartMarker.ps1):
- msiexec Mark-6.2.1.msi /qn /norestart LAUNCHNTLARS=false (the LaunchNtlars
  custom action otherwise fires under /qn and launches NTLARS mid-install,
  same as eDNC).
- After install: import WJPRT.reg rewritten to WOW6432Node (reg import does
  not honor /reg:32; DNC is 32-bit and reads the redirected hive), then copy
  the Mark overlay + eMxInfo.txt into C:\Program Files (x86)\Mark.

HeatTreat (02-Setup-HeatTreat.ps1):
- msiexec HeatTreat_6.2.1.msi /qn /norestart LAUNCHNTLARS=false. Existing
  09-Setup-Heattreat.ps1 (OpenText) still runs after. Optional .reg/file
  copy left as a marked TODO pending confirmation.

Both MSIs decompiled: WiX/GE Aviation, no forced reboot, only LaunchCondition
is NOT NEWERVERSIONDETECTED. utilpassword.txt is gitignored (secret, deployed
via the enrollment share from the working tree).

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-01 10:59:45 -04:00
cproudlock
8cd0c147d8 imaging: renumber stages to be time-monotonic (1=WinPE, 7=Intune ID)
Previously the stage indices reflected logical milestones but not the
order they fire in. Run-ShopfloorSetup posted idx=1 (start) and idx=4
(PPKG) - but 09-Setup-Keyence (inside per-type loop) ran BETWEEN them
and posted idx=5/6. The dashboard then "regressed" from 6 back to 4
when PPKG fired, making it look stuck at the per-type-complete card.

New numbering matches actual execution order:

  1 - WinPE: PESetup / WIM apply              (startnet.cmd)
  2 - Run-ShopfloorSetup: starting            (Run-ShopfloorSetup.ps1)
  3 - 09-Setup-<Type>: starting               (per-type)
  4 - 09-Setup-<Type>: complete               (per-type)
  5 - Run-ShopfloorSetup: PPKG enrollment     (Run-ShopfloorSetup.ps1)
  6 - Run-ShopfloorSetup: handoff to Monitor  (Run-ShopfloorSetup.ps1)
  7 - Monitor-IntuneProgress: Intune Device ID captured

services/imaging_status.py rewind threshold reverts to stage_index <= 1
now that WinPE startnet posts idx=1.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-13 11:34:01 -04:00
cproudlock
908b668bde shopfloor: instrument 09-Setup-CMM, Common, Heattreat with Send-PxeStatus
Wires the imaging-progress helper into the three PC-type setup scripts
that were either clean (CMM) or untracked (Common, Heattreat). Each
gains two calls per the pattern committed for Keyence in 9122b28:

  * idx 5/8 - "09-Setup-<Type>: starting" right after the session start banner
  * idx 6/8 - "09-Setup-<Type>: complete" just before the completion banner

Display, Genspect, and WaxAndTrace also got the same two-line additions
locally and on the live server, but those files have pre-existing WIP
edits intermixed so they aren't staged here. They'll travel along
when the operator commits their unrelated shopfloor work.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-13 10:17:24 -04:00
cproudlock
6dcf96e40a Phase 3+4 rename reorg: repo dir renames + startnet.cmd menu
Pairs with Phase 1+2 from earlier (alias maps in Install-FromManifest,
GE-Enforce, Get-PCProfile, verify-state). See project-shopfloor-rename-reorg
memory for the plan.

Phase 3 (repo + paths):
- git mv per-PC-type dirs to gea-shopfloor-* names:
    Standard      -> gea-shopfloor-collections
    CMM           -> gea-shopfloor-cmm
    Keyence       -> gea-shopfloor-keyence
    Genspect      -> gea-shopfloor-genspect
    WaxAndTrace   -> gea-shopfloor-waxtrace
    Display       -> gea-shopfloor-display
    Lab           -> gea-shopfloor-common (folded; Timeclock+Lab merge)
- New gea-shopfloor-nocollections/ (clone of collections sans UDC scripts).
- New gea-shopfloor-heattreat/ (placeholder, README only).
- Move Standard/ntlars-backups/ -> _ntlars-backups/ (per-MN, not per-type).
- Run-ShopfloorSetup.ps1: Resolve-PCTypeDir helper walks alias group when
  the on-disk dir for the current pcType is missing. Set-MachineNumber
  helper-copy gated on collections|nocollections|legacy Standard-Machine.
- Update-MachineNumber.ps1: pcProfiles lookups try gea-shopfloor-collections
  first, fall back to legacy Standard-Machine. PowerShell 5.1 compatible
  (no null-coalesce).

Phase 4 (startnet.cmd menu):
- Choice 3 "GEA Shopfloor" now drills into a 9-item sub-menu instead of
  going straight to enrollment. Sub-cats:
    1. Machine with Collections        -> gea-shopfloor-collections
    2. Machine without Collections     -> gea-shopfloor-nocollections
    3. Common (Timeclock, Lab)         -> gea-shopfloor-common
    4. Keyence                         -> gea-shopfloor-keyence
    5. CMM                             -> gea-shopfloor-cmm
    6. Genspect                        -> gea-shopfloor-genspect
    7. Heattreat                       -> gea-shopfloor-heattreat
    8. Wax and Trace                   -> gea-shopfloor-waxtrace
    9. Display                         -> gea-shopfloor-display
- Office menu (existing 6-option) follows for every sub-cat.
- Machine number prompt only for collections + nocollections.
- pc-subtype.txt + display-type.txt no longer written. PCTYPE is a
  single full string (gea-shopfloor-*); subtype-aware code paths fall
  back to empty and resolve via the alias map.
- CMM bootstrap stage gate switched from "%PCTYPE%"=="CMM" to
  "%PCTYPE%"=="gea-shopfloor-cmm".

Test harness:
- B-enforce/run.sh PCSUBTYPE default changed from "Machine" to "" so
  single-arg invocation matches the new single-string scheme. Two-arg
  legacy form ("Standard Machine") still works via aliasing.
- B-enforce/tamper.ps1 alias-aware Test-MatrixEntryMatches mirroring
  verify-state.ps1.

Smoke-tested on win11 VM as SYSTEM via qga: B-enforce harness 5-phase
cycle (stage / baseline / tamper / heal / idempotent) passes 10/10
with PCType=gea-shopfloor-collections AND with legacy "Standard Machine"
two-arg form.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-04 08:09:16 -04:00