H1 corp_admin_cidrs (UFW 22/9009 on the corp NIC from these only; refuses
when it would lock out the current SSH client) and corp_ssh_password_auth
(sshd drop-in, passwords only from the imaging subnet). Defaults keep the
current behaviour and print a loud warning.
H2 pxe-netplan-apply.sh: pre-flight refusal (pxe-MAC NIC holds the default
route, a DHCP lease or the route to an SSH client), run from the USB
before anything changes; post-apply checks (names, imaging IPv4, corp
IPv4 back within 30 s, SSH route) and a 120 s systemd-run auto-revert.
H3 restore() puts the previous NIC names back (two-phase rename via
temporary names, so swaps work) before generate + apply.
H4 a failed rename is fatal (restore + exit 1); the play drops the old
any-interface UFW rules only after verifying both NICs and their
per-interface SSH rules.
H5 first-boot checks the playbook exit code, retries at next boot (max 5),
writes /var/lib/pxe-firstboot.failed and /etc/issue + /etc/motd banners.
M1 build-usb.sh verifies iPXE files against the playbook pins, every wheel
against its own package's hashes, drops the unpinned pip fallback,
requires --site-vars or --no-site-vars.
M2 webapp restarts when the code, wheels or unit changed.
M3 ignore-carrier on the imaging NIC; ip_nonlocal_bind kept for the
apache/networkd boot race.
M4 menu suffix must match blancco_kver; missing kernel with no earlier
build is fatal; a live menu with the staged Blancco test entry is not
overwritten.
M5 build-proxmox-iso.sh is unsupported (hard exit); use build-usb --image.
M6 deploy-unattend.sh: password via SSHPASS env and sudo stdin only,
%q-quoted remote args, sha256 check of the live file; lint-unattend.py
reads PXE_SERVER/PXE_USER/PXE_PASS and uses sshpass -e.
M7 the playbook lints the unattend files before the force: yes copies
(lint-unattend.py ships on CIDATA as scripts/); pre-commit ACMR.
M8 Blancco initramfs build: no ignore_errors, pipefail, trap cleanup.
Also: Send-ImagingStage.ps1 deploy, carrier hook install tasks
(pxe-nic-carrier, networkd-dispatcher), L1 imaging-active hold
(allow_disruptive) and no iPXE downgrade below an Updates-page install,
L2 iso-volid, L3 kver pin read from the playbook, L4 cp -rL, L5 refuse
>= 4 GiB WinPE files, L6 PIP_DIR wipe guard, L7 per-package wheel hashes,
no online fallback, L8 check-updates.py (apt_pkg/cached compare, all
components, exit 2 on no debs / bad answers).
Well-formed XML is not enough. Windows Setup validates against a schema and one
bad value invalidates the WHOLE answer file for its pass, so the machine stops at
a dialog with nothing configured and the only clue is an XPath buried in
C:\Windows\Panther\setupact.log.
On 2026-08-06 every shopfloor, standard and engineer build was failing exactly
that way:
/settings/RunSynchronous/RunSynchronousCommand/[Order="16"]/Path
Description = Value is invalid. hrResult = 0x80220005 pass = specialize
An inlined "powershell.exe -Command ..." had grown to 676 characters in a field
capped at 259, and had been broken since the previous evening. Every check here
is mechanical and would have caught it before a bay was booted:
path-too-long RunSynchronousCommand/Path > 259
cmdline-too-long SynchronousCommand/CommandLine > 1024
description-too-long Description > 256
duplicate-element a once-only element appearing twice
not-well-formed XML does not parse
bom UTF-8 BOM (the live files have none, and python's
utf-8-sig silently ADDS one when writing them back)
unknown-token %token% PESetup will not substitute; %WINDIR% and the
other shell variables are excluded or it cries wolf
Reads over SSH via base64 so a BOM or CRLF survives the hop unchanged. Exits
non-zero on any ERROR so it can gate a deploy.
Immediately found a second live defect the manual review had missed: a 329-char
Description on gea-engineer Order 11, which would have failed the oobeSystem pass
once specialize started passing. All three live image types and both repo copies
now lint clean.