Single-site bay-stuck issue at WJ: GE Intune Report IP script filters
Get-NetIPAddress on StartsWith("10.") and posts everything matching
to the GE Tines webhook. Bays at WJ get the PXE LAN 10.9.100.x IP
captured and reported -> GE backend tags bays as on a non-corp 10.x
subnet -> dynamic group eligibility for SFLD policy never matches.
Other GE sites work because their PXE LANs aren't on 10.x at all.
Renumber PXE LAN to RFC1918 172.16.9.0/24 so the GE filter naturally
skips wired PXE addresses without any disable-NIC dance.
Server-side already in flight (netplan dual-bound, dnsmasq scope +
boot URL repointed, blancco preferences + grub.cfg + iPXE GetPxeScript
all sed'd to 172.16.9.1). This commit is the playbook / scripts /
docs side: 109 hits across 35 files sed'd in one shot.
After this lands + boot.wim is rebuilt + bays renumber off DHCP,
the 10.9.100.1 binding will be dropped from netplan as the final
cleanup step.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
PowerShell parses $var: as scope-namespaced syntax (e.g. $env:NAME,
$global:foo). The line
Log "server=$PxeServer:$Port pctype=$PCType"
errored at line 26 col 13 - parser interpreted $PxeServer: as a scope
prefix and bailed. Fix: use ${PxeServer}:${Port} so the colon is
literal. The $uri line below already had the right form.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
The inline one-liner in startnet.cmd called Get-NetAdapter, which is
not available in WinPE's stripped PowerShell (no NetTCPIP module).
Errors silently swallowed by the surrounding try/catch - POST never
fired, dashboard never showed bays during the WIM-apply phase.
Externalize to a standalone .ps1 on the enrollment share:
* Uses wmic (always present in WinPE 10+) for both serial AND mac
instead of Get-CimInstance / Get-NetAdapter.
* Logs every step to X:\Windows\Temp\winpe-status-push.log so a
future "POST didn't fire" debug is one file read away.
* startnet.cmd now just runs powershell -File Y:\scripts\winpe-status-
push.ps1. Future edits to the push logic do NOT require a boot.wim
rebuild; just edit the .ps1 on the share.
Mirror the existing pattern for run-enrollment.ps1 / wait-for-internet.ps1
/ migrate-to-wifi.ps1 (all already at /srv/samba/enrollment/scripts/).
Add the new file to the playbook's enrollment-scripts copy loop.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>