Commit Graph

5 Commits

Author SHA1 Message Date
cproudlock
6e218f3daf CMM/DODA: Install-DODA does the full unattended runtime+app install
The vendor GE_DODA_build5_Installer.exe is a multi-app NSIS bundler whose /S
silent mode is broken (nested sub-install -> MSI 1619); VM-confirmed it only
works interactively. So Install-DODA now drives the bundled components directly,
all silent:
  python-2.7.16 msi /qn  -> C:\Python27
  openjdk-1.8.0.232 msi /qn -> C:\Program Files\RedHat
  gs927w64.exe /S        -> Ghostscript 9.27
  vc_redist /quiet
  doda_build*.zip        -> C:\Apps\DODA  (+ writes .settings the zip lacks)
Then sets AFDA_INSTALL_DIR + Java PATH, precompiles .py->.pyc as admin, and
grants Users+Auth Users Full on C:\Apps\DODA so the locked-down operator can run
DovetailAnalysis.exe (writes .pyc/PreProcess/$TMP). Each step detects-and-skips;
idempotent. VM-validated end to end incl a non-admin operator-paths test.

Runtime binaries (python/jdk/gs/vc msis + doda zip) are staged on the share, not
committed.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-17 19:54:15 -04:00
cproudlock
b5b644a360 CMM/DODA: restore on DODA bays + grant Full on whole C:\Apps\DODA
- Restore-CMM: drop the skip-on-doda gate. DODA bays now restore the
  config-version PC-DMIS + goCMM settings like any other bay (they have backups
  now; DODA itself installs separately to C:\Apps\DODA and is unaffected).
- sync-cmm-backups.sh: update the stale "do not back up DODA bays" note.
- Install-DODA.ps1: grant Users + Authenticated Users Full on the WHOLE
  C:\Apps\DODA (was PreProcess only) - DODA writes output/temp throughout the
  folder as the locked-down operator. /T covers PreProcess.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-17 17:22:06 -04:00
cproudlock
1487abdba5 CMM/DODA: enable on bays 4/10/11/12, fix PCTypes match, grant PreProcess ACL
Three fixes so DODA actually deploys on the four bays that need it:

- cmm-bay-config.csv: doda=yes for CMM4, CMM10, CMM11, CMM12 (was no on all
  bays). Drives doda.txt -> startnet pc-subtype.txt=doda -> the cmm-doda path.
- cmm-manifest.json: DODA entry PCTypes "cmm-doda" -> "gea-shopfloor-cmm-doda".
  The old value never matched: Test-PCTypeMatches builds the PC identity set as
  {gea-shopfloor-cmm, gea-shopfloor-cmm-doda, CMM} (the alias of the cmm type is
  bare CMM, no subtype variant), so "cmm-doda" was in no set and the entry was
  silently skipped. Must be the exact Type-SubType string.
- Install-DODA.ps1: grant Users + Authenticated Users Full on C:\Apps\DODA\
  PreProcess (icacls, SIDs, OI/CI inherit), applied every run. MergeFiles.exe
  writes there as the locked-down operator; without it the merge step fails.

Not yet pushed to the SFLD/enrollment share (server unreachable at commit time).
Not smoke-tested - no pwsh available here; logic-traced only.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-17 16:35:39 -04:00
cproudlock
57fae57d3b CMM/DODA: fix DODA paths + CyberArk EPM policy doc
- 09-Setup-CMM.ps1: Step 2.5 ACL list targeted C:\Program Files\DODA (a path
  that never exists), so the BUILTIN\Users write grant on DODA was silently
  skipped. Corrected to C:\Apps\DODA, where Install-DODA.ps1 actually extracts.
- Install-DODA.ps1: create C:\Apps\DODA\PreProcess after extract. The DODA
  zip unpacks flat without it; MergeFiles.exe expects it and crashed with
  DirectoryNotFoundException (MergeFiles.GetDoDAFolder) when absent.
- docs/cyberark-cmm-doda-policy.md: EPM admin reference for elevating the CMM
  report toolchain. CyberArk EPM elevation is per-process and not inherited, so
  the external tools PC-DMIS spawns (MergeFiles/PCDToIGES/RotateProbeVector/
  DovetailAnalysis) run un-elevated and fail. Doc gives the Application Group
  (by SHA-256), the Elevate policy, scope, verify steps, and the
  CREATE_PDF_FROM_RTF.BAS rework that drops Word/Reader from the elevation set.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-01 12:38:34 -04:00
cproudlock
5e13d38512 CMM per-bay PC-DMIS version selection + DODA deploy
Add bay picker (same arrow-key pattern as waxtrace) that maps CMM1-12
to a PC-DMIS version (2016/2019/2026) and DODA flag via cmm-bay-config.csv.

startnet.cmd: replace Standard/DODA submenu with bay picker. Writes
CMMID (e.g. CMM4) to machine-number.txt so the existing
TargetMachineNumbers filter on the SFLD share manifest gates per-bay
entries with no lib changes.

09-Setup-CMM: reads resolved version.txt and filters cmm-manifest.json
by _CmmVersion tag at imaging time so only the matched PC-DMIS version
installs.

cmm-manifest.json: add PC-DMIS 2026.1 entry (patched MSI, product code
{81BACE1B-FB08-4DCF-8100-79911AD3EC1E}) and DODA entry (flat zip extract
to C:\Apps\DODA\). Existing 2016/2019 entries tagged with _CmmVersion.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-27 12:01:27 -04:00