The extracted VC++ 2008/2010/2012/2013/2022 MSIs have a hardcoded
CustomAction CA_LaunchCondition (type 19 = msidbCustomActionTypeError)
whose Target is "To install this product, please run Setup.exe. For
other installation options, see the Installation section of ReadMe.htm."
The CA's Condition row in InstallExecuteSequence is:
NOT( (ADDEPLOY = 1 OR NOVSUI = 1 OR VSEXTUI = 1 OR
ADVERTISED = 1 OR ProductState >= 1) )
So it fires (= aborts the install with that error) unless one of those
sentinel properties is set on the command line. The 2008 MSI uses a
slightly different name (CA_LaunchCondition_5122) and a different set:
NOT( (USING_EXUIH = 1 OR USING_EXUIH_SILENT = 1 OR ProductState >= 1) )
The bootstrappers normally set NOVSUI=1 / USING_EXUIH_SILENT=1 to
identify themselves as non-interactive installers. When we run the
extracted MSI directly via msiexec, the property isn't set, the CA
fires, msiexec returns 1603 with MSI Note 1: 1708, and the install
rolls back.
Fix: pass both properties unconditionally on every VC++ install. MSIs
ignore unknown properties, so one args string works for all of them.
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
The Microsoft VC++ bootstrappers (vcredist*_x86.exe) ignore /norestart
and trigger immediate Windows reboots when CRT DLLs are in use, which
in practice is always. We saw this break a live Standard PC imaging
run (installlog showed the manual shutdown -a sequence between runs).
Fix follows the existing 2008 pattern: extract the inner MSIs from
each Burn bundle, run them via msiexec with REBOOT=ReallySuppress
(a hard Windows Installer property the bootstrapper can't override),
and treat exit 3010 as success. Files are now staged per-version
under dependencies/vcredist/<version>/ because each MSI's Media table
hardcodes its CAB filename, so the pairs would otherwise collide.
preinstall.json: 4 EXE entries replaced with 8 MSI entries (Min+Add
for 2012/2013/2022 because each version's Burn bundle ships them
as separate MSIs). 2008 also moved into the same vcredist/2008/
subdir for consistency. ProductCodes verified against the existing
detection paths (the previous "bootstrapper" GUIDs were actually
the Min runtime GUIDs inherited up the chain).
sync-preinstall.sh: now tarballs the dependencies/vcredist/ subtree
to preserve directory structure across the scp+sudo-cp boundary,
flat installers (UDC, Oracle) still copied individually, and the
remote install script now removes the legacy flat vc_red.msi/cab
plus the obsolete vcredist*_x86.exe bootstrappers on every sync.
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
Adds a local-install pipeline so Standard shopfloor PCs get Oracle, the
VC++ redists (2008-2022), and UDC installed during PXE imaging via Samba
instead of pulling ~215 MB per device from Azure blob over the corporate
WAN. Intune DSC then verifies (already-installed apps are skipped) and
the only Azure traffic on the happy path is ~11 KB of CustomScripts
wrapper polling.
New files:
- playbook/preinstall/preinstall.json — curated app list with PCTypes
filter and per-app detection rules. Install order puts VC++ 2008
LAST so its (formerly) reboot-triggering bootstrapper doesn't kill
the runner mid-loop. (2008 itself now uses extracted vc_red.msi with
REBOOT=ReallySuppress; the reorder is defense in depth.)
- playbook/shopfloor-setup/Shopfloor/00-PreInstall-MachineApps.ps1 —
the runner. Numbered 00- so it runs first in the baseline sequence.
Reads preinstall.json, filters by PCTYPE, polls for completion via
detection check (handles UDC's hung WPF process by killing it once
detection passes), uses synchronous WriteThrough logging that
survives hard reboots, preserves log history across runs.
- playbook/shopfloor-setup/Standard/Set-MachineNumber.{ps1,bat} — desktop
helper for SupportUser. Reads current UDC + eDNC machine numbers,
prompts via VB InputBox, validates digits-only, kills running UDC,
edits both C:\ProgramData\UDC\udc_settings.json and HKLM\…\GE Aircraft
Engines\DNC\General\MachineNo, relaunches UDC. Lets a tech assign a
real machine number to a mass-produced PC without admin/LAPS.
- playbook/sync-preinstall.sh — workstation helper to push installer
binaries from /home/camp/pxe-images/main/ to the live PXE Samba.
Changes:
- playbook/startnet.cmd + startnet-template.cmd — add xcopy to stage
preinstall bundle from Y:\preinstall\ to W:\PreInstall\ during the
WinPE imaging phase, gated on PCTYPE being set.
- playbook/pxe_server_setup.yml — create /srv/samba/enrollment/preinstall
+ installers/ directories and deploy preinstall.json there.
- playbook/shopfloor-setup/Run-ShopfloorSetup.ps1 — bump AutoLogonCount
to 99 at start (defense against any installer triggering an immediate
reboot mid-dispatcher; final line still resets to 2 on successful
completion). Copy Set-MachineNumber.{ps1,bat} to SupportUser desktop
on Standard PCs.
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>