cproudlock
c595d3b9cb Shopfloor unattend: move Orders 4/5 logic to external PS1 scripts
FlatUnattendW10-shopfloor.xml was rejected by Windows OOBE with
"the answer file is invalid" after the earlier tower-no-WiFi fix.
Root cause: the inline PowerShell in <CommandLine> for Orders 4 and
5 exceeded the SynchronousCommand CommandLine length limit (~1024
chars) and/or contained characters the unattend schema validator
dislikes.

Fix: move the logic to two external PS1 scripts and shrink both
CommandLine entries to ~85 chars each that just invoke the scripts.

- playbook/wait-for-internet.ps1: 60s interactive prompt ("connect
  production network now"), then poll TCP 443 to login.microsoft-
  online.us for up to 10 min with a hard timeout so the loop always
  exits. Uses Test-NetConnection -Port 443 (not Test-Connection /
  ICMP) because Microsoft 365 edges do not reliably respond to ping.
- playbook/migrate-to-wifi.ps1: Gates the entire wired-disable
  migration on "does a WiFi adapter exist?" If not (tower), the
  script is a no-op. If yes, disable wired / wait for WiFi internet
  with a 5 min timeout / re-enable wired on timeout fallback.
- startnet.cmd stages both new scripts to W:\Enrollment\ next to
  run-enrollment.ps1 during the WinPE phase.
- FlatUnattendW10-shopfloor.xml Orders 4 and 5 shrunk to short
  invocations of C:\Enrollment\wait-for-internet.ps1 and
  C:\Enrollment\migrate-to-wifi.ps1.
- startnet-template.cmd kept in sync.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-11 16:50:58 -04:00
cproudlock
3ea20b271e Shopfloor unattend: fix tower (no-WiFi) hang on internet wait
FlatUnattendW10-shopfloor.xml Orders 4 and 5 hung forever on
desktops/towers with no WiFi NIC. Two underlying bugs:

1. Order 4 used Test-Connection (ICMP) against login.microsoftonline.us.
   Microsoft 365 endpoints do not reliably respond to ICMP, so even
   with working TCP 443 internet the ping loop ran forever. Symptom
   on a user-facing machine was the PowerShell window permanently
   stuck on "Waiting for internet connectivity...".
2. Order 5 unconditionally disabled all wired adapters and waited for
   WiFi internet. On a tower with no WiFi NIC this left the machine
   completely offline, and the following while loop waited for a WiFi
   connection that could never happen.

Fixes:
- Order 4 now emits a 60s interactive prompt asking the user to
  connect to the production network (so towers have a window to
  unplug PXE and plug into a production port), then uses
  Test-NetConnection -Port 443 with a 10 min hard timeout so the
  loop always exits.
- Order 5 checks for a physical WiFi adapter first; if none exists
  (tower case), it logs "No WiFi adapter - staying on ethernet" and
  returns immediately instead of disabling wired. If WiFi is present
  and migration times out, wired adapters are re-enabled as a
  fallback so the machine is never left offline.

Both orders now use Test-NetConnection -Port 443 instead of
Test-Connection (ICMP) so ICMP-blocking firewalls and non-responsive
cloud endpoints no longer produce infinite waits.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-11 14:25:41 -04:00
cproudlock
76165495ff Shopfloor PC type system, webapp enhancements, slim Blancco GRUB
- Shopfloor PC type menu (CMM, WaxAndTrace, Keyence, Genspect, Display, Standard)
- Baseline scripts: OpenText CSF, Start Menu shortcuts, network/WinRM, power/display
- Standard type: eDNC + MarkZebra with 64-bit path mirroring
- CMM type: Hexagon CLM Tools, PC-DMIS 2016/2019 R2
- Display sub-type: Lobby vs Dashboard
- Webapp: enrollment management, image config editor, UI refresh
- Upload-Image.ps1: robocopy MCL cache to PXE server
- Download-Drivers.ps1: Dell driver download pipeline
- Slim Blancco GRUB EFI (10MB -> 660KB) for old hardware compat
- Shopfloor display imaging guide docs

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-03-26 11:25:07 -04:00
cproudlock
6d0e6ee284 BIOS check fix, parallel downloads, shopfloor hardening
- Fix check-bios.cmd: replace parenthesized if blocks with goto labels
  (cmd.exe fails silently with if/else on network-mapped drives)
- Move BIOS check files to winpeapps/_shared/BIOS for reliable SMB access
- Add network wait loop before BIOS check in startnet.cmd
- Show firmware status in WinPE menu header (BIOS_STATUS variable)
- Add BypassNRO registry key to skip OOBE network requirement
- Refactor download-drivers.py with --parallel N flag (ThreadPoolExecutor)
- Set SupportUser AutoLogonCount to 3 in shopfloor unattend
- Add shutdown -a at start + shutdown /r /t 10 at end of Run-ShopfloorSetup.ps1
- Switch download-drivers.py from wget to curl for reliable stall detection

Co-Authored-By: Claude Opus 4.6 <noreply@anthropic.com>
2026-03-23 11:02:36 -04:00