Commit Graph

12 Commits

Author SHA1 Message Date
cproudlock
2461804fc8 CMM: Backup-CMM also captures the whole C:\Program Files\WAI tree
Adds a wai_backup_<PC>_<ts>.zip (robocopy /E of C:\Program Files\WAI + the x86
path) alongside the goCMM + PC-DMIS backups, indexed in cmm-backup-index.json.
Captures machine/controller content beyond the per-version PC-DMIS grab. Can be
multi-GB if WAI holds the full PC-DMIS 2016 install.

NOTE: this only CAPTURES it. sync-cmm-backups.sh + Restore-CMM still handle only
gocmm/pcdmis zips - staging/restoring the WAI zip needs those updated too.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-19 10:40:01 -04:00
cproudlock
48bc609eb5 CMM/DODA: fix DODA-bay profile resolution + goCMM 2.12 DataFolder + settings converter
- Get-PCProfile: subtype-strip fallback. DODA bays set pc-subtype.txt=doda, so
  the profile key became "gea-shopfloor-cmm-doda" which matched NO profile/alias
  -> Get-PCProfile returned null -> callers fell to hardcoded defaults (no
  PC-DMIS desktop icons; Defect Tracker / WJ Shopfloor / Plant Apps force-started).
  Now an unmatched compound key falls back to the bare pc-type (-> CMM). VM-tested:
  gea-shopfloor-cmm/doda + CMM/doda resolve to CMM (7 apps, PC-DMIS present);
  non-CMM unaffected.
- 09-Setup-CMM Step 2.5c: Active Setup seed for goCMM 2.12 DataFolder. goCMM 2.12
  stores its shared-data-dir in HKCU\Software\General Electric\goCMM\DataFolder
  (decompiled: RegistrySettings uses Registry.CurrentUser - per-user). Imaging as
  SupportUser wouldn't reach the ShopFloor operator's HKCU. Active Setup runs the
  StubPath once per user at first logon -> every user gets DataFolder=C:\geaofi\.
  VM-tested: StubPath writes the value with the trailing backslash intact.
- Convert-goCMMSettings.ps1: converts legacy goCMM 1.1 ApplicationSettings.xml ->
  goCMM 2.12 goCMMSettings.xml schema. VM-tested: output byte-identical to a real
  goCMM-2.12-produced CMM10 goCMMSettings.xml.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-19 08:59:08 -04:00
cproudlock
132c57ab39 CMM: create C:\GE PC-DMIS FRONT END at imaging + move regserver helper to Public desktop
- Ensure-PCDMISFrontEnd.ps1/.bat: standalone fix for already-imaged bays -
  create C:\GE PC-DMIS FRONT END + grant Users/Auth Users Modify. PCDToIGES.exe
  writes its error log there in its catch block; on a fresh bay the dir is absent
  (legacy front-end setup isn't part of imaging), so ANY PCDToIGES error becomes
  an unhandled DirectoryNotFoundException that crashes the export and masks the
  real cause (confirmed live on a CMM bay).
- 09-Setup-CMM Step 2.5b: create that dir + ACL at imaging for every CMM bay.
- 09-Setup-CMM Step 2.5: Register-PCDMIS-COM.bat now lands on the Public desktop
  (visible to operator or SupportUser) instead of SupportUser-only.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-18 11:56:00 -04:00
cproudlock
b5b644a360 CMM/DODA: restore on DODA bays + grant Full on whole C:\Apps\DODA
- Restore-CMM: drop the skip-on-doda gate. DODA bays now restore the
  config-version PC-DMIS + goCMM settings like any other bay (they have backups
  now; DODA itself installs separately to C:\Apps\DODA and is unaffected).
- sync-cmm-backups.sh: update the stale "do not back up DODA bays" note.
- Install-DODA.ps1: grant Users + Authenticated Users Full on the WHOLE
  C:\Apps\DODA (was PreProcess only) - DODA writes output/temp throughout the
  folder as the locked-down operator. /T covers PreProcess.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-17 17:22:06 -04:00
cproudlock
7af66575d0 CMM: gocmm-debug - capture the real startup NRE (PC-DMIS COM not registered)
debug.log from the bay shows the part group enumerates fine (14 .geop files
opened), then goCMM connects to PC-DMIS over COM and throws:

  System.ArgumentNullException: Value cannot be null. Parameter name: type
     at System.Activator.CreateInstance(Type type)
     at GEAE.Common.CMM.CMMInterfaces.PCDMIS.PCDMIS.<ConnectToSoftware>b__43_0()
  -> System.NullReferenceException at ConnectToSoftware(...)

Root cause: PC-DMIS automation server is not COM-registered, so
Type.GetTypeFromProgID returns null -> CreateInstance(null) throws -> the NRE
is the downstream symptom. Not part-group, not permissions, not calibration.

- PROBE 4: pull the .NET Runtime / Application Error crash stack for goCMM from
  the Application log so the next run captures the null in one shot.
- PROBE 5: (a) part-group UNC reachability; (b) PC-DMIS COM registration check
  (PCDLRN.* ProgID -> CLSID -> LocalServer32) that names the missing registration
  and the Pcdlrn.exe /regserver fix; plus install presence for context.
- .bat header documents the COM root cause.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-17 08:31:11 -04:00
cproudlock
8e11f0824a CMM: gocmm-debug probes the startup NRE (part-group match), checks real exe
goCMM matches the registry 'Selected Part Group' against the
ApplicationSettings.xml <PartGroup FullName> entries with a case-sensitive
compare. No match -> SelectedPartGroup null -> "Object reference not set to
an instance of an object" at start. This is a different failure from the
registry SecurityException the script already probes.

- PROBE 3: read the reg value (32-bit view) + every FullName in the XML,
  Ordinal-compare, and report exact / case-only / no-match / missing-XML.
  Case-only and no-match name the d441abd canonicalization fix as the remedy.
- Version check now looks for the real goCMM.exe, not the nonexistent
  GEAOperatorFriendlyInterface.exe (was a false MISSING).
- .bat header documents both failure modes it now diagnoses.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-17 08:08:00 -04:00
cproudlock
d441abd20f CMM: goCMM restore - canonicalize the SHARE segment case, not just the host
goCMM showed an empty parts list after restore though the bay reached the share.
Decompiled goCMM: PartGroupViewModel matches the registry Selected Part Group
against ApplicationSettings.xml <PartGroup FullName> with a CASE-SENSITIVE compare,
then enumerates that FullName for the parts. The host-canon rewrite fixed only the
hostname, leaving xml '\shared' (lowercase) vs registry '\SHARED' (uppercase) ->
Find null -> SelectedPartGroup null -> empty list. Fix spans the share segment too,
pinning both to \tsgwp00525.wjs.geaerospace.net\SHARED. Verified in PowerShell
(-ceq True). Runs at imaging in Restore-CMM, so all captured backups are fixed on
restore with no re-backup.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-14 13:12:07 -04:00
cproudlock
e97e5bd049 shopfloor: CMM PC-DMIS version gate, ShopDB reporter fixes, staging self-heal
- lib Install-FromManifest 2.5->2.6: add _CmmVersion per-entry filter (reads
  C:\Enrollment\cmm\version.txt). Lifted the version gate out of 09-Setup-CMM
  into the shared lib so imaging and GE-Enforce apply it identically and cannot
  drift (root cause of PC-DMIS 2016 installing on every CMM).
- Install-goCMMSettings: canonicalize the part-group share host to the FQDN in
  both the registry and ApplicationSettings.xml. Handles bare \\tsgwp00525\ and
  the legacy rd.ds.ge.com domain; idempotent. VM-tested.
- Report-AssetToShopDB: resolve the machine number eDNC registry first, then fall
  back to C:\Enrollment\machine-number.txt (matches the lib resolution order) so
  a freshly imaged PC still reports its number for the PC-machine relationship.
- Add Update-CMMEnforcer.ps1/.bat: update one CMM's local lib to the gated
  version and self-heal its PC-DMIS version.
- Add Debug-ShopDBReporting.ps1/.bat: one-shot reporter triage (preconditions,
  client log, live test POST, verdict).
- Add Verify-And-Heal-Staging.ps1/.bat: post-boot check that every imaging
  payload arrived and re-pull anything missing from the share, including the CMM
  bundle and the selected bay's backup (the payload that times out in WinPE).

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-14 09:14:54 -04:00
cproudlock
c2538a05c5 CMM: wire per-bay settings restore into the imaging flow
Restore-CMM.ps1 (new) restores a CMM's PC-DMIS + goCMM settings at imaging from
its staged backup. Self-gating: reads C:\Enrollment\cmm\{cmmid,version,doda,
partgroup}.txt, skips DODA bays and bays with no staged backup, and restores
ONLY the config-version PC-DMIS zip via the existing Install-*Settings scripts.
Same-bay restore (cmmid match) so the backed-up controller CommPort is this
bay's own value - no cross-bay clobber.

Version selection matches the VERSION FIELD of the zip name, anchored on the
trailing timestamp, so version=2026 does not false-match a 2019/2016 zip whose
backup timestamp (20260612...) merely contains "2026".

09-Setup-CMM.ps1: new Step 2.8 calls Restore-CMM after app install + first-run
init (so a restored config is not clobbered by PC-DMIS defaults) and before the
C:\CMM-Install cleanup (the backup set lives under <stagingRoot>\backups\<cmmid>).
Best-effort: Restore-CMM always exits 0, imaging never fails on a restore.

startnet.cmd: stage ONLY the picked bay's backup into C:\CMM-Install\backups\
%CMMID% (the bulk robocopy now /XD-excludes the backups tree, which holds every
bay's backup - some 240 MB each - to avoid copying GBs to every imaged CMM).
Also bump the PPKG to v4.16 (the live boot.wim was already v4.16; the repo had
drifted to v4.14).

sync-cmm-backups.sh: source the backups from pxe-images/cmm/backups (where
Backup-CMM writes via the pulled-down copies), not the old cmm-bk path.

Smoke tested on the win11 VM against CMM3's real backup: version=2019 restored
the 2019 R2 zip (not 2016.0), imported HKLM+HKCU reg, converted the part-group
S:\ path to the tsgwp00525 UNC, created C:\geaofi, exit 0; version=2026 correctly
found no matching zip (anchor works).

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-12 15:34:10 -04:00
cproudlock
59deaea714 CMM: Backup-CMM defaults to S: record-retention path + prompts for CMM#
Default output is now S:\2 WJ Scans Record Retention\backup\cmm\<CmmId>\ instead
of C:\Logs. If S: is not mapped/reachable it falls back to C:\Logs\CMM\cmm-backup
so the backup still runs. When -CmmId is not passed the script prompts for it
(loops until non-empty) since it names the per-bay folder.

Smoke tested on the win11 VM: S: fallback path + the Read-Host prompt (fed via
redirected stdin) both produce the correctly-named per-CMM folder.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-12 15:34:10 -04:00
cproudlock
1d65103cc0 CMM: add PC-DMIS + combined CMM backup/restore + diagnostic scripts
Adds the PC-DMIS settings/probe backup-restore set alongside the existing
goCMM scripts, plus a single combined CMM backup and the diagnostics built
while debugging the live bays:

- Backup-PCDMISSettings / Install-PCDMISSettings: capture+restore PC-DMIS
  registry + data/probe/cal files per installed version (2016/2019/2026).
  Hardened from real-bay failures: detect install dir via Program Files
  fallback; capture compens.dat (not just comp.dat) + interfac.dll; identify
  the controller by hash-matching interfac.dll to its source DLL AND reading
  the PE OriginalFilename (covers rename-without-copy); EXCLUDE the whole
  Homepage state (Recent/Favorites/DetailsView) which null-refs PC-DMIS on
  launch via stale routine paths; restore routes HKCU into the target user's
  hive (-TargetUser ShopFloor), fails loud on a non-backup path, and applies
  the legacy->new FQDN rewrite across reg + data files incl .bas.
- Backup-CMM: one wrapper running goCMM + PC-DMIS (all versions) into one
  per-CMM folder + index, for staging on PXE and restore-by-machine-number.
- Clear-PCDMISRecent: fixes the Homepage recent-list NullReferenceException
  crash on an already-broken bay.
- pcdmis-probe-debug / Export-PCDMISCrashEvents: diagnostics for the
  custom-probe-not-showing and crash investigations.
- Modify-PCDMISRights / Grant-FullControl: grant the operator the registry +
  filesystem access PC-DMIS needs under lockdown.
- Install-goCMMSettings: add .bas to the FQDN-rewrite include list.

Not yet wired into 09-Setup-CMM auto-restore - staging + the gated restore
block come next.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-12 08:42:32 -04:00
cproudlock
bfe17fe123 CMM: add goCMM settings backup/restore + debug scripts
goCMM settings live in two places: 3 pointer values at
HKLM\SOFTWARE\WOW6432Node\General Electric\goCMM, and the real content of all
7 Settings tabs (PC-DMIS, Quindos, Modus, Machine Definition, User Input,
Notifications, Part Groups) in C:\geaofi\ApplicationSettings.xml. Capture-replay
pair, mirroring the Wax/Trace Backup/Install scripts:

- Backup-goCMMSettings.ps1/.bat: on a live legacy bay (admin), zips the registry
  key + the C:\geaofi tree (minus transient LocalProgramCopies/logs) to
  gocmm_backup_<PC>_<ts>.zip.
- Install-goCMMSettings.ps1/.bat: restore at imaging (admin). Imports the key +
  lays down C:\geaofi, then grants BUILTIN\Users WriteKey on the reg key and
  Modify on C:\geaofi - goCMM's RegistrySettings.GetRegistryString opens the key
  with writable:true even to READ, so a locked-down operator throws a
  SecurityException without the grant (the post-lockdown 'registry access not
  allowed' error). Applies a built-in legacy->new FQDN rewrite
  (rd.ds.ge.com -> wjs.geaerospace.net) automatically across the registry values
  and ApplicationSettings.xml (incl PartGroup FullName); -NoDefaultRewrite skips
  it, /replace adds an extra pair, -SelectedPartGroup overrides per bay.
- gocmm-debug.ps1/.bat: run as the operator to reproduce the SecurityException
  and dump the goCMM key ACL (confirms whether lockdown stripped the grant).

All round-trip + FQDN-rewrite verified on the win11 VM. NOTE: covers goCMM only;
PC-DMIS probe calibrations / custom tip angles / machine comp are owned by
PC-DMIS (Hexagon) and not captured here. Not yet wired into 09-Setup-CMM
auto-discovery.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-11 08:27:30 -04:00