Commit Graph

6 Commits

Author SHA1 Message Date
cproudlock
bc123c1066 Machine number input at PXE menu for Standard PCs
Adds a machine number prompt to startnet.cmd after the Standard sub-type
selection. Tech enters the number during the PXE boot process. Defaults
to 9999 if Enter is pressed (existing placeholder behavior).

Written to C:\Enrollment\machine-number.txt alongside pc-type.txt.

Consumers:
  00-PreInstall-MachineApps.ps1 - replaces 9999 in UDC InstallArgs with
    the entered number, so UDC installs with the correct machine number
    from the start (no post-setup Set-MachineNumber needed).
  01-eDNC.ps1 - writes the machine number to the DNC\General\MachineNo
    registry value during eDNC install.
  Configure-PC.ps1 - existing $needsMachineNumber check already skips
    the prompt when UDC/eDNC aren't at 9999, so no change needed.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-11 08:50:02 -04:00
cproudlock
6c76719a47 Logging, PCTypes, edge profiles for all types
Three final optimization batches:

1. Start-Transcript added to 4 scripts that lacked standalone logging:
   04-NetworkAndWinRM.ps1, 05-OfficeShortcuts.ps1, 01-eDNC.ps1,
   02-MachineNumberACLs.ps1. Each writes to C:\Logs\SFLD\<name>.log
   with append mode. Stop-Transcript added before exit points.

2. preinstall.json: Oracle Client PCTypes changed from ["*"] to
   ["Standard", "CMM", "Genspect", "Keyence", "WaxAndTrace", "Display"].
   Lab Workstations don't need Oracle Client (shopfloor data app
   dependency). VC++ redists stay at ["*"] (harmless shared deps).

3. Edge profiles added to all remaining PC types in site-config.json:
   CMM, Genspect, Keyence, WaxAndTrace, Standard-Timeclock all get the
   standard 3-tab setup (Plant Apps + Homepage + Dashboard) with
   homepage = tsgwp00524. Display-Lobby and Display-Dashboard get
   Shopfloor Dashboard as both homepage and single tab.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-10 11:57:22 -04:00
cproudlock
0aaf049942 Extract site-specific values to site-config.json
New site-config.json file at C:\Enrollment\ (staged by startnet.cmd from
the enrollment share) contains all West Jefferson-specific values that were
previously hardcoded across 7 scripts. To deploy at a different GE site,
clone site-config.json and change the values - scripts need zero changes.

Config schema (v1.0):
  siteName / siteNameCompact  - UDC/eDNC site args
  urls{}                      - Edge startup tab fallback URLs
  edgeStartupTabs[]           - ordered tab list with .url file basenames
  opentext{}                  - excluded .hep profiles and .lnk shortcuts
  startupItems[]              - Configure-PC toggle list (exe/existing/url)
  taskbarPins[]               - 07-TaskbarLayout pin order with lnk paths
  desktopApps[]               - 06-OrganizeDesktop Phase 2 app list

Every script uses the same inline Get-SiteConfig helper that reads the
JSON and returns $null if missing/corrupt. All consumers fall back to the
current hardcoded West Jefferson defaults when $siteConfig is null, so
PXE servers without a site-config.json continue working identically.

Scripts updated:
  06-OrganizeDesktop.ps1   - desktopApps array from config
  07-TaskbarLayout.ps1     - pinSpec array from config
  08-EdgeDefaultBrowser.ps1 - startup tab loop from config
  Configure-PC.ps1         - startup items + site name from config
  Check-MachineNumber.ps1  - site name from config
  Set-MachineNumber.ps1    - site name from config
  01-eDNC.ps1              - siteName + siteNameCompact from config
  startnet.cmd             - copies site-config.json from enrollment share

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-10 11:11:35 -04:00
cproudlock
ded0a7184b Shopfloor scripts: em-dash to hyphen, add positional Level param
Replace em-dash characters with plain hyphens across the 5 shopfloor
setup scripts (avoids cp1252 mojibake in .bat files and keeps the
PowerShell sources consistent). Also adds [Parameter(Position=1)] to
Write-PreInstallLog so the Level argument can be passed positionally.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-08 14:24:37 -04:00
cproudlock
9c54307b1b Shopfloor cleanups: drop OpenText CSF + MarkZebra, gitignore eMxInfo
- Delete 02-OpenTextCSF.ps1 (CSF profile delivery moved to Intune YAML's
  CopyFiles section in main/device-config.yaml — no longer needed at the
  PXE/baseline layer)
- Strip MarkZebra install + post-config from 01-eDNC.ps1 (no longer
  needed; only eDNC core install + Dnc x86→x64 mirror + Site reg + eMxInfo
  deployment remain). Section numbering tightened.
- Add SITESELECTED="West Jefferson" to eDNC msiexec args so the MSI's
  site-specific Components (NtLarsWjfRegComp — FTP/FMS/PPDCS hosts +
  credentials) actually install. Without it, only the bare Site value was
  being set and all the connection details were unconfigured.
- gitignore: blanket-block any **/eMxInfo*.txt from being committed —
  the file contains obfuscated eDNC site credentials and must never go
  in git. Canonical source lives at /home/camp/pxe-images/main/eMxInfo.txt
  outside the repo.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-08 14:05:52 -04:00
cproudlock
76165495ff Shopfloor PC type system, webapp enhancements, slim Blancco GRUB
- Shopfloor PC type menu (CMM, WaxAndTrace, Keyence, Genspect, Display, Standard)
- Baseline scripts: OpenText CSF, Start Menu shortcuts, network/WinRM, power/display
- Standard type: eDNC + MarkZebra with 64-bit path mirroring
- CMM type: Hexagon CLM Tools, PC-DMIS 2016/2019 R2
- Display sub-type: Lobby vs Dashboard
- Webapp: enrollment management, image config editor, UI refresh
- Upload-Image.ps1: robocopy MCL cache to PXE server
- Download-Drivers.ps1: Dell driver download pipeline
- Slim Blancco GRUB EFI (10MB -> 660KB) for old hardware compat
- Shopfloor display imaging guide docs

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-03-26 11:25:07 -04:00