WinPE now reports each machine's WMI model, manufacturer, Dell system
SKU and BIOS version to /hardware/seen (winpe-status-push.ps1, best
effort, wmic only). The webapp records every model seen and checks it
against what the server has:
- each image's Deploy/Control/HardwareDriver.json, matched exactly as
PESetup's GetDriverByModel does (as reimplemented in
lint-driver-catalogue.py), plus whether the pack's zip is on disk;
- the WinPE BIOS manifest (substring match like check-bios.cmd).
/hardware lists every model with per-image driver status and BIOS
status. A model missing a Win11 pack or a BIOS entry becomes item 5 on
the Technician To-Do (and the banner count) until the pack/BIOS is added
or it is dismissed. Virtual machines are ignored.
Also deploys the repo winpe-status-push.ps1 over the live copy, which
predated the -CurrentStage/-StageIndex parameters startnet.cmd passes
for the BIOS-flash stage, so that status post was failing.
Automates the Blancco parts of the onsite-support CMMC playbook:
- ENT-056/158 evidence pack: /reports/evidence?month=YYYY-MM returns
ENT-056_<Site>_<YYYY-MM>.zip (summary.csv, README, each report's XML
and PDF). pxe-blancco-evidence.timer saves last month's pack to the
reports share's evidence/ folder on the 1st (Persistent).
- ENT-045/159 ServiceNow tick list: /reports/servicenow lists recent
reports as "Wiped" or "Blancco Wipe failed" with a pre-written
destruction note, copy buttons and Done (CSRF-protected).
- Cloud upload: blancco-progress.py posts each report's upload result
("Sending report document id" -> "Report sent to MC") to
/reports/cloud-status (CSRF-exempt like /imaging/status); the Reports
page and the CSVs show it, so a wipe missing from BMP is visible.
- CSV gains failure_reason (exception messages, failed steps, error
counts), business_location and cloud_upload.
- Preferences: business_location "West Jefferson" (config.BLANCCO_SITE)
and pdf+xml reports; the report copier now copies the PDF too, named
after its XML. .part and hidden files are not listed as reports.
State (cloud confirmations, ServiceNow ticks) is a JSON file at
/var/lib/pxe-webapp/blancco-state.json, off the report share.
Adds end-to-end progress tracking for PXE imaging sessions and surfaces
each Blancco report's BIOS serial in the report list.
webapp:
* services/imaging_status.py - JSON-per-serial state store under
IMAGING_DIR (default /var/log/pxe-imaging). Atomic write via
tempfile + rename. log_tail capped at 50 lines. Merges partial
updates so clients can post just the current_stage tick.
* config.py - new IMAGING_DIR env-overridable path.
* services/csrf.py - explicit exempt list for machine-to-machine
endpoints; /imaging/status is the first entry. Air-gapped LAN;
trust-by-network for client posts.
* app.py - four new routes:
GET /imaging dashboard (renders all sessions)
POST /imaging/status client status push (JSON body)
GET /imaging/<serial>.json raw session JSON for ad-hoc polling
POST /imaging/delete/<s> clear a session from the dashboard
Also parses each Blancco XML in the /reports list to surface
system.serial + system.model columns.
* templates/imaging.html - Bootstrap dashboard with per-session
cards (state badge, progress bar, stage idx/total, mac, elapsed,
log tail). meta http-equiv refresh=5 for auto-tick.
* templates/base.html - new "Imaging Progress" nav entry.
* templates/reports.html - Serial + Model columns added.
playbook:
* shopfloor-setup/Shopfloor/lib/Send-PxeStatus.ps1 - new helper.
Dot-source this then call Send-PxeStatus -Stage X -StageIndex N
-StageTotal M from any stage script. BIOS serial via CIM, MAC via
Get-NetAdapter, pctype + machinenumber from C:\Enrollment.
Failures are swallowed to a local log so a network blip doesn't
block imaging.
* shopfloor-setup/Run-ShopfloorSetup.ps1 - dot-sources helper +
posts at three coarse milestones (start, PPKG enrollment,
handoff to Monitor-IntuneProgress).
* shopfloor-setup/gea-shopfloor-keyence/09-Setup-Keyence.ps1 -
posts at session start + after Install-FromManifest with
succeeded/failed status derived from $rc. Other 09-Setup-*.ps1
scripts can follow the same pattern.
ID is BIOS serial (stable across WinPE -> Windows transition and
across reboots, unlike hostname which is random pre-PPKG). Operator
already knows the serial of the bay they imaged.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>