New tools:
Configure-PC.bat/.ps1 - Interactive desktop tool for SupportUser to
configure a shopfloor PC after imaging. Two sections:
1. Machine number: if UDC/eDNC are still at placeholder 9999, prompt
to set the real number right now (updates UDC JSON + eDNC registry,
restarts UDC.exe with new args).
2. Auto-startup toggle: pick which apps start at user logon from a
numbered list (UDC, eDNC, Defect Tracker, WJ Shopfloor, Plant Apps).
Creates/removes .lnk files in AllUsers Startup folder. Toggle UI
shows [ON]/[ ] state, safe to re-run anytime. Plant Apps URL
resolved from .url file at runtime with hardcoded fallback to
https://mes-wjefferson.apps.lr.geaerospace.net/run/...
3. Item 6 in the toggle list: register/unregister a "Check Machine
Number" logon task for standard (non-admin) users. When enabled,
the task fires at every logon, checks for 9999, pops an InputBox
if found, updates both apps, then unregisters itself on success.
Check-MachineNumber.ps1 - The logon task script. Runs as the logged-in
user (needs GUI for InputBox), not SYSTEM. Writing to ProgramData + HKLM
is possible because 02-MachineNumberACLs.ps1 pre-grants BUILTIN\Users
write access on the two specific targets during imaging.
02-MachineNumberACLs.ps1 - Standard type-specific script (runs after
01-eDNC.ps1). Opens C:\ProgramData\UDC\udc_settings.json for Users:Modify
and HKLM:\...\GE Aircraft Engines\DNC\General for Users:SetValue. Narrow
scope, not blanket admin.
Execution order fixes in Run-ShopfloorSetup.ps1:
The dispatcher now has two lists: $skipInBaseline (scripts NOT run in the
alphabetical baseline loop) and $runAfterTypeSpecific (scripts run
explicitly after type-specific scripts complete). This fixes the bug where
06/07 ran before 01-eDNC.ps1 installed DnC, so eDNC/NTLARS shortcuts were
silently skipped.
New execution order:
Baseline: 00-PreInstall, 04-NetworkAndWinRM (skipping 05-08 + tools)
Type-specific: 01-eDNC, 02-MachineNumberACLs
Finalization: 06-OrganizeDesktop, 07-TaskbarLayout
06 internally calls 05 (Office shortcuts, Phase 0) and 08 (Edge config,
Phase 4) as sub-phases, so they also benefit from running late. Office
isn't installed until after the first reboot (ppkg streams C2R), so 05
no-ops at imaging time but succeeds when 06's SYSTEM logon task re-runs
it on the second boot. 08 resolves startup-tab URLs from .url files
delivered by DSC (even later); same self-heal via the logon task.
Other fixes in this commit:
- OpenText Setup-OpenText.ps1 Step 4: exclude WJ_Office.lnk, IBM_qks.lnk,
mmcs.lnk desktop shortcuts (matching the Step 3 .hep profile exclusion
from the previous commit). Removes stale copies from prior installs.
- 05-OfficeShortcuts.ps1: widened Office detection to 6 path variants
covering C2R + MSI + Office15/16, with diagnostic output on miss.
- 06-OrganizeDesktop.ps1: removed Phase 3 (desktop-root pin copies for
eDNC/NTLARS) so shortcuts live in Shopfloor Tools only, not duplicated
at root. Emptied $keepAtRoot. Added Phase 0 (call 05) and Phase 4
(call 08). Lazy folder creation + empty-folder cleanup. Scheduled task
now runs as SYSTEM (was BUILTIN\Users with Limited which failed the
admin check). Added NTLARS to 07's taskbar pin list.
- 08-EdgeDefaultBrowser.ps1: Plant Apps URL fallback hardcoded from
device-config.yaml.
- All new scripts have Start-Transcript logging to C:\Logs\SFLD\ with
timestamps and running-as identity.
- Run-ShopfloorSetup.ps1: Start-Transcript + Stop-Transcript wrapping
entire dispatcher run, writes to C:\Logs\SFLD\shopfloor-setup.log.
Configure-PC.bat added to SupportUser desktop copy list.
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
Replace em-dash characters with plain hyphens across the 5 shopfloor
setup scripts (avoids cp1252 mojibake in .bat files and keeps the
PowerShell sources consistent). Also adds [Parameter(Position=1)] to
Write-PreInstallLog so the Level argument can be passed positionally.
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
Adds a local-install pipeline so Standard shopfloor PCs get Oracle, the
VC++ redists (2008-2022), and UDC installed during PXE imaging via Samba
instead of pulling ~215 MB per device from Azure blob over the corporate
WAN. Intune DSC then verifies (already-installed apps are skipped) and
the only Azure traffic on the happy path is ~11 KB of CustomScripts
wrapper polling.
New files:
- playbook/preinstall/preinstall.json — curated app list with PCTypes
filter and per-app detection rules. Install order puts VC++ 2008
LAST so its (formerly) reboot-triggering bootstrapper doesn't kill
the runner mid-loop. (2008 itself now uses extracted vc_red.msi with
REBOOT=ReallySuppress; the reorder is defense in depth.)
- playbook/shopfloor-setup/Shopfloor/00-PreInstall-MachineApps.ps1 —
the runner. Numbered 00- so it runs first in the baseline sequence.
Reads preinstall.json, filters by PCTYPE, polls for completion via
detection check (handles UDC's hung WPF process by killing it once
detection passes), uses synchronous WriteThrough logging that
survives hard reboots, preserves log history across runs.
- playbook/shopfloor-setup/Standard/Set-MachineNumber.{ps1,bat} — desktop
helper for SupportUser. Reads current UDC + eDNC machine numbers,
prompts via VB InputBox, validates digits-only, kills running UDC,
edits both C:\ProgramData\UDC\udc_settings.json and HKLM\…\GE Aircraft
Engines\DNC\General\MachineNo, relaunches UDC. Lets a tech assign a
real machine number to a mass-produced PC without admin/LAPS.
- playbook/sync-preinstall.sh — workstation helper to push installer
binaries from /home/camp/pxe-images/main/ to the live PXE Samba.
Changes:
- playbook/startnet.cmd + startnet-template.cmd — add xcopy to stage
preinstall bundle from Y:\preinstall\ to W:\PreInstall\ during the
WinPE imaging phase, gated on PCTYPE being set.
- playbook/pxe_server_setup.yml — create /srv/samba/enrollment/preinstall
+ installers/ directories and deploy preinstall.json there.
- playbook/shopfloor-setup/Run-ShopfloorSetup.ps1 — bump AutoLogonCount
to 99 at start (defense against any installer triggering an immediate
reboot mid-dispatcher; final line still resets to 2 on successful
completion). Copy Set-MachineNumber.{ps1,bat} to SupportUser desktop
on Standard PCs.
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
- AutoLogonCount reduced from 2 to 1 in Run-ShopfloorSetup.ps1
- Remove default pinned Start Menu tiles and set blank layout for future users
- Add sync_intune.bat: triggers MDM sync and polls for SFLD group policies
- Update README.md and SETUP.md with current project state (boot chain, new
scripts, samba shares, webapp pages, commit history)
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
- Fix check-bios.cmd: replace parenthesized if blocks with goto labels
(cmd.exe fails silently with if/else on network-mapped drives)
- Move BIOS check files to winpeapps/_shared/BIOS for reliable SMB access
- Add network wait loop before BIOS check in startnet.cmd
- Show firmware status in WinPE menu header (BIOS_STATUS variable)
- Add BypassNRO registry key to skip OOBE network requirement
- Refactor download-drivers.py with --parallel N flag (ThreadPoolExecutor)
- Set SupportUser AutoLogonCount to 3 in shopfloor unattend
- Add shutdown -a at start + shutdown /r /t 10 at end of Run-ShopfloorSetup.ps1
- Switch download-drivers.py from wget to curl for reliable stall detection
Co-Authored-By: Claude Opus 4.6 <noreply@anthropic.com>