cproudlock
d5398bdd74 imaging: LAPS-password-to-QR generator per bay card
Per-bay <details> section with:
 - Input field for LAPS password (paste from Intune portal manually,
   since deep-link to LAPS blade needs AAD objectId we can't obtain)
 - Make QR button generates a client-side QR from the input
 - QR displayed below at 280px with 4-cell quiet zone
 - Auto-clears input + QR after 60s with live countdown
 - Manual Clear button
 - Enter key on the input also triggers QR generation

Password never POSTs to server, never logged, never persists past the
60s window. Generated using the same qrcode-generator lib already
loaded for the device-id QR. Scan with a USB barcode scanner plugged
into the bay (HID keyboard mode) -> password types into bay login
field. Faster than reading off the Intune portal letter-by-letter.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-14 19:48:43 -04:00
cproudlock
cdb6655e4a imaging: drop LAPS deep-link, keep only category
LAPS retrieval blade is keyed on AAD object id, not aadDeviceId /
mdmDeviceId. We capture aadDeviceId from dsregcmd; resolving to
objectId would require a Graph API call with Device.Read.All which
we don't have at WJ. Removed the LAPS button - operator goes to
Intune portal manually for LAPS as before.

set-category button stays - aadDeviceId works for that blade.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-14 19:47:46 -04:00
cproudlock
74ba3d1339 imaging: deep-link buttons for Set Category + LAPS per bay
Two buttons next to the Intune device id on each bay card:
 - "set category" -> portal.azure.us Intune device blade properties
   via aadDeviceId/{deviceId}
 - "LAPS" -> intune.microsoft.us encryptionKeys blade via
   mdmDeviceId/{deviceId}

Both use the dsregcmd DeviceId we already capture - no Graph API
lookup or objectId resolution needed. One click from the dashboard
takes the tech to the right page for category assignment or LAPS
retrieval.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-14 19:20:10 -04:00
cproudlock
ce604adcda Renumber PXE LAN from 10.9.100.0/24 to 172.16.9.0/24
Single-site bay-stuck issue at WJ: GE Intune Report IP script filters
Get-NetIPAddress on StartsWith("10.") and posts everything matching
to the GE Tines webhook. Bays at WJ get the PXE LAN 10.9.100.x IP
captured and reported -> GE backend tags bays as on a non-corp 10.x
subnet -> dynamic group eligibility for SFLD policy never matches.
Other GE sites work because their PXE LANs aren't on 10.x at all.

Renumber PXE LAN to RFC1918 172.16.9.0/24 so the GE filter naturally
skips wired PXE addresses without any disable-NIC dance.

Server-side already in flight (netplan dual-bound, dnsmasq scope +
boot URL repointed, blancco preferences + grub.cfg + iPXE GetPxeScript
all sed'd to 172.16.9.1). This commit is the playbook / scripts /
docs side: 109 hits across 35 files sed'd in one shot.

After this lands + boot.wim is rebuilt + bays renumber off DHCP,
the 10.9.100.1 binding will be dropped from netplan as the final
cleanup step.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-14 16:30:32 -04:00
cproudlock
0eb52c6a9e imaging: copy button HTTP fallback (execCommand)
navigator.clipboard.writeText is gated on isSecureContext - HTTPS
or localhost only. PXE dashboard is served over plain HTTP
(10.9.100.1:9009) so the API was undefined and the chain threw
before .catch fired - user saw nothing. Wrap clipboard write in
copyText() that prefers the modern API and falls back to the
classic invisible-textarea + document.execCommand('copy') path
which works on HTTP. Visual flash logic moved into flashCopied()
for reuse.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-13 18:30:16 -04:00
cproudlock
6275a6a2b3 imaging: add visual feedback to device-id copy button
Click effect: button flashes green with "copied!" text and 1.15x
scale pulse, reverts after 1.2s. Failure case (clipboard API blocked
or HTTP context) shows red "failed" for 1.5s. Handler moved out of
inline onclick into a single delegated click listener at the doc
level so future copy buttons just need the .copy-btn class +
data-copy-text attribute.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-13 18:29:00 -04:00
cproudlock
59dbd64e37 Fix Report IP glob (.LOG not .txt) + add device-id copy button
Field bay surfaced two bugs in one diag dump (mdm-diag-F907T5X3 -
6PPSF24):

1. GE Proactive Remediation Report IP actually writes
   GE_Report_IP_Address_2_5.LOG (uppercase .LOG), not the .txt I
   assumed. Globs in two places had .txt filter -> never matched ->
   Phase 1 stuck IN PROGRESS forever even after the file landed and
   wired-NIC re-enable never fired. Drop extension from both globs
   in Monitor-IntuneProgress.ps1 (id=7 push gate + p1Done check).

2. The "GE Re-enable Wired NICs" SYSTEM task registered by
   Run-ShopfloorSetup was polling Autologon_Remediation.log for
   "Autologon set for ShopFloor" - a lockdown-time signal. Re-enable
   needs to fire at Report-IP time (well before lockdown) so that
   Monitor can push idx=7 with the QR before the Intune-triggered
   LAPS-prompt reboot. Repoint the SYSTEM task's poll to
   C:\Logs\GE_Report_IP_Address* (any extension).

Plus minor UX: copy button next to the Intune device ID on
/imaging dashboard so techs can grab the GUID without having to
double-click-select the <code>.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-13 18:27:26 -04:00
cproudlock
a8d38f6117 imaging: load Send-PxeStatus at script scope + bump QR size to 160px
Monitor-IntuneProgress.ps1: the previous Ensure-SendPxeStatus function
ran '. $lib' from inside the function body. PowerShell's dot-source-
inside-function semantics put the imported Send-PxeStatus into the
function's LOCAL scope, not the script scope. By the time Get-Phase1
called Get-Command Send-PxeStatus, the function had already returned
and Send-PxeStatus was out of scope - silently never invoked, no log
entry at all (success or failure). Diagnostic confirmed: bay had
DeviceId in dsregcmd, manual Send-PxeStatus from operator prompt
fired idx=7 cleanly with QR rendered, but Monitor's automatic call
never showed up in C:\Logs\send-pxe-status.log.

Fix: dot-source at script top-level (outside any function). Then
Send-PxeStatus is in script scope where every function in the file
can call it. Keep Ensure-SendPxeStatus as a no-op stub for any caller
still invoking it.

imaging.html: bump QR data-qr-size from 56 to 160 px. A 36-char UUID
at ECC M needs ~29x29 modules; at 56px each module was ~1.5px which
is too tight for a phone camera to lock onto from typical distance.
160 px gives ~5 px/module which scans cleanly.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-13 15:41:52 -04:00
cproudlock
9122b28c31 webapp: imaging progress dashboard + serial column on reports list
Adds end-to-end progress tracking for PXE imaging sessions and surfaces
each Blancco report's BIOS serial in the report list.

webapp:
  * services/imaging_status.py - JSON-per-serial state store under
    IMAGING_DIR (default /var/log/pxe-imaging). Atomic write via
    tempfile + rename. log_tail capped at 50 lines. Merges partial
    updates so clients can post just the current_stage tick.
  * config.py - new IMAGING_DIR env-overridable path.
  * services/csrf.py - explicit exempt list for machine-to-machine
    endpoints; /imaging/status is the first entry. Air-gapped LAN;
    trust-by-network for client posts.
  * app.py - four new routes:
      GET  /imaging               dashboard (renders all sessions)
      POST /imaging/status        client status push (JSON body)
      GET  /imaging/<serial>.json raw session JSON for ad-hoc polling
      POST /imaging/delete/<s>    clear a session from the dashboard
    Also parses each Blancco XML in the /reports list to surface
    system.serial + system.model columns.
  * templates/imaging.html - Bootstrap dashboard with per-session
    cards (state badge, progress bar, stage idx/total, mac, elapsed,
    log tail). meta http-equiv refresh=5 for auto-tick.
  * templates/base.html - new "Imaging Progress" nav entry.
  * templates/reports.html - Serial + Model columns added.

playbook:
  * shopfloor-setup/Shopfloor/lib/Send-PxeStatus.ps1 - new helper.
    Dot-source this then call Send-PxeStatus -Stage X -StageIndex N
    -StageTotal M from any stage script. BIOS serial via CIM, MAC via
    Get-NetAdapter, pctype + machinenumber from C:\Enrollment.
    Failures are swallowed to a local log so a network blip doesn't
    block imaging.
  * shopfloor-setup/Run-ShopfloorSetup.ps1 - dot-sources helper +
    posts at three coarse milestones (start, PPKG enrollment,
    handoff to Monitor-IntuneProgress).
  * shopfloor-setup/gea-shopfloor-keyence/09-Setup-Keyence.ps1 -
    posts at session start + after Install-FromManifest with
    succeeded/failed status derived from $rc. Other 09-Setup-*.ps1
    scripts can follow the same pattern.

ID is BIOS serial (stable across WinPE -> Windows transition and
across reboots, unlike hostname which is random pre-PPKG). Operator
already knows the serial of the bay they imaged.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-13 10:07:18 -04:00