goCMM (.NET x86) stores its program-source path in HKLM\SOFTWARE\
WOW6432Node\General Electric\goCMM value 'Shared Data Directory'. Being
HKLM, a non-admin shopfloor user cannot set it via goCMM's UI (nor save a
Selected Part Group switch). 09-Setup-CMM Step 2.7 now seeds the per-bay
path (admin context at imaging) and grants BUILTIN\Users write on the key,
mirroring the existing Step 2.5 install-dir ACL grant.
- cmm-bay-config.csv: add shared_data_dir column (per-bay paths, CMM1-12).
- resolve-cmm-bay-config.ps1: write C:\Enrollment\cmm\shareddatadir.txt
(space-safe; e.g. CMM8 'Venture CMM8').
- 09-Setup-CMM.ps1: Step 2.7 reg seed + Users ACL on the goCMM key.
Not yet deployed to the live server (held).
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Add bay picker (same arrow-key pattern as waxtrace) that maps CMM1-12
to a PC-DMIS version (2016/2019/2026) and DODA flag via cmm-bay-config.csv.
startnet.cmd: replace Standard/DODA submenu with bay picker. Writes
CMMID (e.g. CMM4) to machine-number.txt so the existing
TargetMachineNumbers filter on the SFLD share manifest gates per-bay
entries with no lib changes.
09-Setup-CMM: reads resolved version.txt and filters cmm-manifest.json
by _CmmVersion tag at imaging time so only the matched PC-DMIS version
installs.
cmm-manifest.json: add PC-DMIS 2026.1 entry (patched MSI, product code
{81BACE1B-FB08-4DCF-8100-79911AD3EC1E}) and DODA entry (flat zip extract
to C:\Apps\DODA\). Existing 2016/2019 entries tagged with _CmmVersion.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>