Commit Graph

3 Commits

Author SHA1 Message Date
cproudlock
f73f999938 Unified Common-Enforce for cross-type apps, add WJF Defect Tracker
Replaces the Acrobat-only enforcer with a generic Common-Enforce that
handles all cross-PC-type apps from one manifest + one scheduled task
on the SFLD share at \\tsgwp00525\shared\dt\shopfloor\common\apps\.

Renames:
  Acrobat-Enforce.ps1        -> Common-Enforce.ps1
  Register-AcrobatEnforce    -> Register-CommonEnforce
  acrobat-manifest.json      -> common-apps-manifest.json
  common.acrobatSharePath    -> common.commonAppsSharePath
  'GE Acrobat Enforce' task  -> 'GE Common Apps Enforce' task
  C:\Program Files\GE\Acrobat -> C:\Program Files\GE\CommonApps

Register-CommonEnforce cleans up the legacy 'GE Acrobat Enforce' task
if present from a prior image.

WJF Defect Tracker (replaces ClickOnce):
  - Added to preinstall.json (PCTypes=*, fleet-wide imaging-time install)
  - MSI staged on PXE at pre-install/installers/
  - Added to common-apps-manifest with FileVersion detection on
    C:\Program Files\WJF_Defect_Tracker\Defect_Tracker.exe
  - site-config + 06-OrganizeDesktop: shortcut changed from ClickOnce
    'existing' to exe-path pointing at the MSI-installed binary
  - Update workflow: drop new MSI on share, bump DetectionValue

CMM 09-Setup-CMM: added goCMM + DODA to the ACL grant list.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-16 11:13:05 -04:00
cproudlock
1a5feefb01 CMM: grant Users Modify on PC-DMIS install dirs for non-admin launch
PC-DMIS writes settings, probe configs, and measurement data to its own
Program Files install directory at runtime. Without Modify permission
for BUILTIN\Users, non-admin accounts (ShopFloor) get a UAC elevation
prompt on every launch. The "run as admin once" workaround can't be
automated because PC-DMIS shows a license dialog on first run that
blocks silently.

Fix: grant BUILTIN\Users Modify with inheritance on:
  - C:\Program Files\Hexagon\PC-DMIS 2016.0 64-bit
  - C:\Program Files\Hexagon\PC-DMIS 2019 R2 64-bit
  - C:\ProgramData\Hexagon

Runs as Step 2.5 in 09-Setup-CMM.ps1 after Install-FromManifest
completes. If the exe also has an embedded requireAdministrator manifest
(separate from the file-permission issue), that will need an additional
fix after testing.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-16 10:38:24 -04:00
cproudlock
f3211dfd29 CMM test iteration: desktop shortcuts, rename to 09-Setup-*, defer NIC re-enable
Rolls up everything from the CMM imaging test iteration tonight. No
single concern - several small, related polish items on the option-3
patched-MSI pipeline and the shopfloor-setup / sync_intune handoff.

- Rename all type-specific "01-Setup-<Type>.ps1" scripts to
  "09-Setup-<Type>.ps1" across CMM, Display, Genspect, Keyence, Lab,
  and WaxAndTrace. The "01-" prefix implied the script runs first in
  the overall sequence when it actually runs between baseline (00, 04)
  and finalization (06, 07). Logs now read "Running CMM setup:
  09-Setup-CMM.ps1" which matches the real position. Standard/
  01-eDNC.ps1 + 02-MachineNumberACLs.ps1 left alone - those digits
  represent real within-type ordering.
- playbook/shopfloor-setup/site-config.json CMM profile updates:
  - startupItems = [] (empty). Previously had WJ Shopfloor auto-launch
    which the user does not want on CMM workstations. Now relies on
    the Get-ProfileValue empty-array fix to not fall through to site
    defaults.
  - desktopApps + taskbarPins gain entries for PC-DMIS 2016, PC-DMIS
    2019 R2, CLM Admin, and goCMM so 06-OrganizeDesktop Phase 2
    materializes them into C:\\Users\\Public\\Desktop\\Shopfloor Tools\\
    and 07-TaskbarLayout pins them. goCMM is under C:\\Program Files
    (x86)\\General Electric\\goCMM\\ (GE product, not Hexagon).
- playbook/shopfloor-setup/Run-ShopfloorSetup.ps1: remove the blocking
  "UNPLUG ethernet cable, press any key" prompt + the interactive
  wired-NIC re-enable. The whole prompt block was a hard blocker on
  the imaging chain that required a human to walk to each PC.
- playbook/shopfloor-setup/Shopfloor/lib/Monitor-IntuneProgress.ps1:
  re-enable wired NICs unconditionally at the top of the transcript.
  This is the new home for the re-enable that used to live behind the
  prompt in Run-ShopfloorSetup. By the time sync_intune fires (after
  PPKG reboot + auto-login + Stage-Dispatcher), the tech has had
  minutes of wall-clock time to physically rewire from PXE to
  production without us blocking on a keypress. Tower case is a
  no-op because migrate-to-wifi.ps1 already left wired enabled.
- Internal comment updates in 09-Setup-CMM.ps1, cmm-manifest.json,
  Install-FromManifest.ps1, and startnet.cmd (+ startnet-template)
  to reflect the new filename.

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-04-11 21:03:09 -04:00