# MTConnect follow-up runbook Written 2026-08-11. Everything here needs a machine this box cannot reach - the SFLD share, the middle-man PC, or a shopfloor bay - so it is yours to run. Work in the order given. Part 1 changes what future installs get; parts 2 and 3 fix bays that are already wrong; parts 4 and 5 are questions to answer before any more code is written. ### Identify every bay by machine number The machine number is the only identifier that stays put. A PC gets replaced or re-imaged and its name changes; the machine it sits at does not. Both machine-to-PC sources used to build this document are point-in-time snapshots and will already have drifted. Every PC name below came from `mtconnect-hostname-machine-map.csv` (12 June), the `Shop Floor PC Name` column of `West Jefferson_Machines.csv`, or the variant captures. Treat them as "this is where the fault was last seen" - useful for finding the bay, never for deciding what to write into it. **The bay knows its own number.** In order of authority: ```powershell # 1. eDNC registry - what GE-Enforce trusts post-imaging (Get-ItemProperty 'HKLM:\SOFTWARE\WOW6432Node\GE Aircraft Engines\DNC\General' -Name MachineNo).MachineNo # 2. the enrollment file imaging writes Get-Content C:\Enrollment\machine-number.txt # 3. UDC (Get-Content C:\ProgramData\UDC\udc_settings.json -Raw | ConvertFrom-Json).GeneralSettings.MachineNumber ``` Or dot-source the lib and ask for both at once: ```powershell . C:\GE Aerospace\lib\Update-MachineNumber.ps1 Get-CurrentMachineNumber # @{ Udc = ...; Ednc = ... } ``` **ShopDB is the live PC-to-machine record**, maintained by the collector rather than by hand, so it beats any CSV: ``` https://tsgwp00525.wjs.geaerospace.net/shopdb/api/computers/by-hostname/ ``` If those disagree with each other, or with the machine plate, stop and resolve that first - a rename applied to the wrong number is worse than the mismatch you started with. --- ## Part 1. Push the Fanuc adapter 3.25.3 to the SFLD share The staged bundle here is already on 3.25.3.0 (`sha256` starts `6e46dcd51affa9e0`). The live share is not. Until this is copied, new installs still get 3.23.0.0. **1.1** From the middle-man PC, with `Z:` on the dev share: ``` Z:\mtconnect-bundles\fanuc\Adapter\ ``` should contain `FanucCppAdapterWinX64.exe` at **3,369,984 bytes**. Confirm before copying: ```powershell (Get-Item Z:\mtconnect-bundles\fanuc\Adapter\FanucCppAdapterWinX64.exe).Length (Get-FileHash Z:\mtconnect-bundles\fanuc\Adapter\FanucCppAdapterWinX64.exe -Algorithm SHA256).Hash.Substring(0,16) # expect 3369984 and 6E46DCD51AFFA9E0 ``` **1.2** Back up what is on the share now, then copy the three files: ```powershell $share = '\\tsgwp00525.wjs.geaerospace.net\shared\dt\shopfloor\main\machineapps\mtconnect-bundles\fanuc\Adapter' Copy-Item $share\FanucCppAdapterWinX64.exe "$share\..\FanucCppAdapterWinX64-3.23.0-replaced-$(Get-Date -f yyyyMMdd).exe" Copy-Item Z:\mtconnect-bundles\fanuc\Adapter\FanucCppAdapterWinX64.exe $share -Force Copy-Item Z:\mtconnect-bundles\fanuc\Adapter\Fwlib64.dll $share -Force Copy-Item Z:\mtconnect-bundles\fanuc\Adapter\fwlibe64.dll $share -Force ``` **1.3** Verify on the share: ```powershell (Get-FileHash $share\FanucCppAdapterWinX64.exe -Algorithm SHA256).Hash.Substring(0,16) # 6E46DCD51AFFA9E0 ``` `adapter.xml` is deliberately NOT copied. The config vocabulary is identical between 3.23 and 3.25.3, and the share's copy carries site settings. **Rollback:** copy the `-3.23.0-replaced-` file back over `FanucCppAdapterWinX64.exe`. --- ## Part 2. Fix the two Makino bays Both have the agent on the machine number and the other three files still on `MAKINO-1`. The fixed `Update-MachineNumber.ps1` converges them. | machine | PC when captured | confirm at the bay | |---|---|---| | **7502** | `G5W5V7V3ESF` | eDNC reg / enrollment file / plate | | **7506** | `G4H8KF33ESF` | eDNC reg / enrollment file / plate | Find the current PC for a machine number in ShopDB rather than trusting the name above; if the PC was replaced, the new one may never have had the bad rename applied, in which case check its four files before doing anything. **2.1** On the bay, elevated PowerShell: ```powershell . C:\GE Aerospace\lib\Update-MachineNumber.ps1 # or wherever the lib landed $r = Update-MTConnectVariantName -NewNumber '7502' ` -Root 'C:\Makino-MTConnect' ` -Targets @( @{ Path='Agent\Devices.xml'; Kind='attr' }, @{ Path='Agent\Devices.EDM.xml'; Kind='attr' }, @{ Path='Data\AdapterDataFile.xml'; Kind='name' }, @{ Path='Agent\Agent.cfg'; Kind='cfg' } ) ` -Services @('Makino Adapter Manager','Makino MTConnect Agent') $r.Updated; $r.Errors ``` Use the bay's own number - do not paste 7502 onto 7506. **2.2** Verify all four agree, and nothing still says MAKINO: ```powershell Select-String -Path C:\Makino-MTConnect\Agent\Devices.xml,` C:\Makino-MTConnect\Agent\Devices.EDM.xml,` C:\Makino-MTConnect\Data\AdapterDataFile.xml,` C:\Makino-MTConnect\Agent\Agent.cfg ` -Pattern 'MAKINO-\d+|7502' ``` **2.3** Confirm it is serving: ```powershell (Invoke-WebRequest http://localhost:5000/current -UseBasicParsing).Content -match '[^<]+' ``` All should read the same number. Then the HTTP probe as in 2.3 (port 5000). --- ## Part 4. Four Fanuc bays with no agent device name | machine (per map) | adapter says | PC when captured | |---|---|---| | **2013** | 4007 | `GJBJC724ESF` | | **7606** | 3126 | `G7QLY5X3ESF` | | **4002** | 4002 | `G6JLMSZ2ESF` | | **2001** | 3115 | `GB07T5X3ESF` | These are not a rename problem - the agent's `devices.xml` has no `` at all, so the agent has nothing to serve. Do NOT run Part 3 on them. On each, collect and send back: ```powershell Get-Service 'MTConnect*' | Select-Object Name,Status,StartType Get-Content C:\MTConnect\Agent\devices.xml -TotalCount 20 Test-Path C:\MTConnect\Agent\devices.xml (Invoke-WebRequest http://localhost:5000/current -UseBasicParsing -TimeoutSec 5).StatusCode Get-Content C:\MTConnect\Agent\agent.log -Tail 30 ``` Note three of the four also disagree with the hostname map on the number (4007 vs 2013, 3126 vs 7606, 3115 vs 2001), so these bays may have been re-purposed without a full reconfigure. --- ## Part 5. Two questions to settle **5.1 DMG Mori - do they need a bundle at all?** Five machines, all flagged `1,2,3` in the machine list, no bundle among the five we ship, and no captured variant. Their controllers are `DMG Mori F31i A5/B5` - Fanuc 31i underneath - so the Fanuc adapter may already serve them. | machine | PC per the machine list | |---|---| | WJ-7401 | `G1KDN7X2ESF` | | WJ-7402 | `G1KCR7X2ESF` | | WJ-7403 | `G1HYK7X2ESF` | | WJ-7404 | `G1HGQ7X2ESF` | | WJ-7405 | `G1KLM7X2ESF` | Those names come from the `Shop Floor PC Name` column of the OneDrive machine list and are subject to the same staleness - look the machine up in ShopDB for the PC that is actually on it today. On any one of them: ```powershell Get-Service | Where-Object { $_.Name -match 'MTConnect|Makino|Coordinator' } | Select-Object Name,Status,StartType Get-ChildItem C:\ -Directory | Where-Object Name -match 'MTConnect|DMG|Coordinator' (Invoke-WebRequest http://localhost:5000/current -UseBasicParsing -TimeoutSec 5).StatusCode ``` If they run the Fanuc bundle already, no new variant is needed and the DMG Coordinator MSI in the OneDrive zip can be ignored. If they collect some other way, or not at all, that is the answer to whether a sixth bundle is worth building. **5.2 Does the live v2 manifest carry the MTConnect entries?** You are on v2. The concern is that the MTConnect entries were left behind in the dead v1 manifest, in which case v2 bays are not getting MTConnect from the manifest engine at all. ```powershell $m = Get-Content '\\tsgwp00525.wjs.geaerospace.net\shared\dt\shopfloor\main\machineapps\machineapps-manifest.json' -Raw | ConvertFrom-Json $m.Applications.Count $m.Applications | ForEach-Object { $_.Name } ``` Expect 8 applications, five of them MTConnect (fanuc, okuma, edncStandard, edncDualSpindle, makino). Anything less and the missing ones never made it to v2. --- ## A note on the CSVs Neither machine-to-PC list will age well: `mtconnect-hostname-machine-map.csv` (12 June) and the `Shop Floor PC Name` column in `West Jefferson_Machines.csv` are both hand-built snapshots, and every PC swap silently invalidates a row. ShopDB now maintains the PC-to-machine link from collector reports, so it corrects itself as bays are re-imaged. Anything that needs to go from a machine number to "which PC is on it today" should ask ShopDB; if a CSV is still wanted for offline use, generate it from ShopDB rather than editing it by hand. ## What I still owe you - Auto-detection of controller and variant for a new machine. The inputs exist (`mtconnect-bay-config.csv` has controller IP and FOCAS port per machine, the machine list has the controller model, the collector already knows the machine number at imaging time) - design pending. - The code fix is committed and pushed as `0d9c4fd` on `pxe-webapp-redesign`. It changes future renames only; it does not reach out and fix these bays.