{ "Version": "1.0", "Site": "West Jefferson", "Applications": [ { "Name": "Oracle Client 10.2.0.3", "Installer": "Oracle 10.2.0.3.msi", "Type": "MSI", "InstallArgs": "/qn /norestart", "DetectionMethod": "Registry", "DetectionPath": "HKLM:\\SOFTWARE\\WOW6432Node\\ORACLE\\KEY_OraClientInfra10_2_0", "DetectionName": "ORACLE_HOME_NAME", "DetectionValue": "OraClientInfra10_2_0", "PCTypes": ["Standard", "CMM", "Genspect", "Keyence", "WaxAndTrace", "Display"] }, { "_comment": "VC++ 2008 SP1 x86 - the bootstrapper (vcredist2008_x86.exe) ignores /norestart and triggers an immediate Windows reboot when files are in use (per Aaron Stebner's MSDN docs). Fix: install the extracted vc_red.msi directly with REBOOT=ReallySuppress, which IS hard-honored by Windows Installer. msiexec may return 3010 (would-have-rebooted-but-suppressed) but won't actually reboot. cab name 'vc_red.cab' is hardcoded in the MSI's Media table - do not rename.", "Name": "VC++ Redistributable 2008 x86", "Installer": "vcredist/2008/installer.msi", "Type": "MSI", "InstallArgs": "/qn /norestart REBOOT=ReallySuppress NOVSUI=1 USING_EXUIH_SILENT=1", "DetectionMethod": "Registry", "DetectionPath": "HKLM:\\SOFTWARE\\WOW6432Node\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\{9BE518E6-ECC6-35A9-88E4-87755C07200F}", "PCTypes": ["*"] }, { "_comment": "VC++ 2010 x86 - same fix as 2008. Bootstrapper ignores /norestart; extracted MSI with REBOOT=ReallySuppress does not.", "Name": "VC++ Redistributable 2010 x86", "Installer": "vcredist/2010/installer.msi", "Type": "MSI", "InstallArgs": "/qn /norestart REBOOT=ReallySuppress NOVSUI=1 USING_EXUIH_SILENT=1", "DetectionMethod": "Registry", "DetectionPath": "HKLM:\\SOFTWARE\\WOW6432Node\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\{F0C3E5D1-1ADE-321E-8167-68EF0DE699A5}", "PCTypes": ["*"] }, { "_comment": "VC++ 2012 x86 Minimum Runtime - extracted from vcredist2012_x86.exe Burn bundle. Same REBOOT=ReallySuppress fix.", "Name": "VC++ Redistributable 2012 x86 (Minimum)", "Installer": "vcredist/2012-min/installer.msi", "Type": "MSI", "InstallArgs": "/qn /norestart REBOOT=ReallySuppress NOVSUI=1 USING_EXUIH_SILENT=1", "DetectionMethod": "Registry", "DetectionPath": "HKLM:\\SOFTWARE\\WOW6432Node\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\{BD95A8CD-1D9F-35AD-981A-3E7925026EBB}", "PCTypes": ["*"] }, { "Name": "VC++ Redistributable 2012 x86 (Additional)", "Installer": "vcredist/2012-add/installer.msi", "Type": "MSI", "InstallArgs": "/qn /norestart REBOOT=ReallySuppress NOVSUI=1 USING_EXUIH_SILENT=1", "DetectionMethod": "Registry", "DetectionPath": "HKLM:\\SOFTWARE\\WOW6432Node\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\{B175520C-86A2-35A7-8619-86DC379688B9}", "PCTypes": ["*"] }, { "_comment": "VC++ 2013 x86 Minimum Runtime - extracted from vcredist2013_x86.exe Burn bundle.", "Name": "VC++ Redistributable 2013 x86 (Minimum)", "Installer": "vcredist/2013-min/installer.msi", "Type": "MSI", "InstallArgs": "/qn /norestart REBOOT=ReallySuppress NOVSUI=1 USING_EXUIH_SILENT=1", "DetectionMethod": "Registry", "DetectionPath": "HKLM:\\SOFTWARE\\WOW6432Node\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\{13A4EE12-23EA-3371-91EE-EFB36DDFFF3E}", "PCTypes": ["*"] }, { "Name": "VC++ Redistributable 2013 x86 (Additional)", "Installer": "vcredist/2013-add/installer.msi", "Type": "MSI", "InstallArgs": "/qn /norestart REBOOT=ReallySuppress NOVSUI=1 USING_EXUIH_SILENT=1", "DetectionMethod": "Registry", "DetectionPath": "HKLM:\\SOFTWARE\\WOW6432Node\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\{F8CFEB22-A2E7-3971-9EDA-4B11EDEFC185}", "PCTypes": ["*"] }, { "_comment": "VC++ 2010 x64 - required by PC-DMIS 2016/2019 R2 on CMM PCs. PCDLRN.exe links against msvcr100.dll and the VS 2010 MFC DLLs which are only provided by this redistributable. Extracted from the PC-DMIS 2016 bundle's attached container (a1 payload). Silent install: /q /norestart. Detection: Uninstall key under the native x64 hive with fixed product GUID.", "Name": "VC++ Redistributable 2010 x64", "Installer": "vcredist/2010-x64/vcredist_x64.exe", "Type": "EXE", "InstallArgs": "/q /norestart", "DetectionMethod": "Registry", "DetectionPath": "HKLM:\\SOFTWARE\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\{1D8E6291-B0D5-35EC-8441-6616F567A0F7}", "DetectionName": "DisplayVersion", "DetectionValue": "10.0.40219", "PCTypes": ["*"] }, { "_comment": "VC++ 2012 x64 - required by PC-DMIS 2016/2019 R2. Same rationale as 2010 x64; PC-DMIS links against msvcr110.dll / MFC110. Extracted from the PC-DMIS 2016 bundle's attached container (a2 payload). Detection on the Minimum Runtime GUID (the main redist wrapper installs both Minimum and Additional sub-packages).", "Name": "VC++ Redistributable 2012 x64", "Installer": "vcredist/2012-x64/vcredist_x64.exe", "Type": "EXE", "InstallArgs": "/q /norestart", "DetectionMethod": "Registry", "DetectionPath": "HKLM:\\SOFTWARE\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\{5AF4E09F-5C9B-3AAF-B731-544D3DC821DD}", "DetectionName": "DisplayVersion", "DetectionValue": "11.0.51106", "PCTypes": ["*"] }, { "_comment": "VC++ 2015-2022 x86 - extracted from vcredist2015_2017_2019_2022_x86.exe Burn bundle. The bundle contains 2022 14.44.35211 plus 8 chained KB updates for older 2015/2017/2019 releases. We install only the 2022 Min+Add MSIs - the CRT v140 ABI is shared across 2015/2017/2019/2022, so the latest pair covers all four versions on Windows 10/11.", "Name": "VC++ Redistributable 2022 x86 (Minimum)", "Installer": "vcredist/2022-min/installer.msi", "Type": "MSI", "InstallArgs": "/qn /norestart REBOOT=ReallySuppress NOVSUI=1 USING_EXUIH_SILENT=1", "DetectionMethod": "Registry", "DetectionPath": "HKLM:\\SOFTWARE\\WOW6432Node\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\{922480B5-CAEB-4B1B-AAA4-9716EFDCE26B}", "PCTypes": ["*"] }, { "Name": "VC++ Redistributable 2022 x86 (Additional)", "Installer": "vcredist/2022-add/installer.msi", "Type": "MSI", "InstallArgs": "/qn /norestart REBOOT=ReallySuppress NOVSUI=1 USING_EXUIH_SILENT=1", "DetectionMethod": "Registry", "DetectionPath": "HKLM:\\SOFTWARE\\WOW6432Node\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\{C18FB403-1E88-43C8-AD8A-CED50F23DE8B}", "PCTypes": ["*"] }, { "_comment": "Adobe Acrobat Reader DC - same version as GEA-Engineering image. Two-step install via Install-AcroReader.cmd wrapper: base MSI with enterprise transform (AcroRead.mst) then DC update patch (AcroRdrDCUpd2500120531.msp). Source files on PXE server at /srv/samba/winpeapps/gea-engineer/Deploy/Applications/extra/adobe/ - copy to /srv/samba/enrollment/preinstall/installers/adobe/.", "Name": "Adobe Acrobat Reader DC", "Installer": "adobe\\Install-AcroReader.cmd", "Type": "EXE", "InstallArgs": "", "DetectionMethod": "File", "DetectionPath": "C:\\Program Files (x86)\\Adobe\\Acrobat Reader DC\\Reader\\AcroRd32.exe", "PCTypes": ["*"] }, { "_comment": "OpenText HostExplorer 15 SP1 ShopFloor - replaced the WJDT-built OpenText.exe Inno wrapper with our own Setup-OpenText.ps1 that does the same install steps (msiexec base + ShopFloor.mst transform + SP1 .msp patch) PLUS fans the per-user profile/keymap/menu/macro content out to Default User and every existing user profile. The Inno wrapper deployed per-user content to {userappdata} which resolves to whichever user is running the installer (SYSTEM under DSC, single user under PreInstall) so Azure-AD users never saw the profiles. Setup-OpenText.cmd is a tiny launcher that hands off to Setup-OpenText.ps1 because the runner only handles MSI/EXE types. All bundled files live in vcredist-style subtree at dependencies/opentext/ and get xcopied through WinPE staging. NO DetectionMethod here on purpose - Setup-OpenText.ps1 owns its own version check by reading version.txt next to itself and comparing to HKLM:\\SOFTWARE\\GE\\OpenText\\Installed; the runner always invokes the wrapper (cost: ~1s of PowerShell launch when up-to-date) so the version constant lives in exactly one place: dependencies/opentext/version.txt.", "Name": "OpenText HostExplorer ShopFloor", "Installer": "opentext\\Setup-OpenText.cmd", "Type": "EXE", "InstallArgs": "", "LogFile": "C:\\Logs\\PreInstall\\Setup-OpenText.log", "PCTypes": ["Standard", "CMM", "Keyence", "Genspect", "WaxAndTrace", "Lab"] }, { "_comment": "UDC_Setup.exe spawns a hidden WPF window (UDC.exe) after install and never exits, so the runner needs KillAfterDetection: true to terminate UDC_Setup.exe + UDC.exe once the registry detection passes. This is an OPT-IN flag - normal installers should NOT set it because killing msiexec mid-install leaves msiserver holding the install mutex and the next msiexec call returns 1618 (Oracle hit this exact bug).", "Name": "UDC", "Installer": "UDC_Setup.exe", "Type": "EXE", "InstallArgs": "\"West Jefferson\" -9999", "KillAfterDetection": true, "DetectionMethod": "Registry", "DetectionPath": "HKLM:\\SOFTWARE\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\UDC", "PCTypes": ["Standard-Machine"] }, { "_comment": "Display kiosk app (Lobby Display or Dashboard). Install-KioskApp.cmd wrapper reads C:\\Enrollment\\display-type.txt to determine which installer to run. Both GEAerospaceLobbyDisplaySetup.exe and GEAerospaceDashboardSetup.exe must be staged in the display\\ subtree alongside the wrapper. Inno Setup /VERYSILENT is idempotent so no detection needed.", "Name": "Display Kiosk App", "Installer": "display\\Install-KioskApp.cmd", "Type": "EXE", "InstallArgs": "", "LogFile": "C:\\Logs\\PreInstall\\Dashboard-install.log", "PCTypes": ["Display"] }, { "_comment": "Shopfloor Standard serial-port drivers: StarTech PCIe serial adapter (MosChip-based) + Prolific PL2303 USB-to-serial. Install-Drivers.cmd runs pnputil /add-driver with /subdirs /install so every bundled INF under drivers/ lands in the Windows driver store and auto-binds to matching hardware present now or plugged in later. Scoped to Standard PCs (both Machine + Timeclock) because the PCTypes filter is type-level only; installing a serial driver on a Timeclock without the hardware is harmless - it just sits in the driver store.", "Name": "Shopfloor Serial Drivers", "Installer": "drivers\\Install-Drivers.cmd", "Type": "EXE", "InstallArgs": "", "LogFile": "C:\\Logs\\PreInstall\\Install-Drivers.log", "DetectionMethod": "File", "DetectionPath": "C:\\ProgramData\\PXEDrivers\\drivers-installed.marker", "PCTypes": ["Standard"] } ] }