pxe-server/webapp/templates
cproudlock 454e30ff6f Floor shows a staged BIOS update from the start of WinPE; NIC speed past 4.29 Gb/s
- winpe-status-push.ps1: check-bios.cmd stages the firmware update before
  the imaging menu, but startnet's 'BIOS firmware update' push only comes
  at the end of WinPE, so builds showed a plain 'Applying image' for the
  whole apply. The first push now reports the staged update when
  X:\bios-fired.flag exists, and the floor shows 'Applying image - BIOS
  update staged' (do not power off during the next reboot). Also: CIM
  fallback for the serial where wmic is missing, and standard/engineer
  always report 5 steps.
- Network pill: cdc_ncm (e.g. the WisdPI RTL8157 5G adapter) keeps link
  speed in a 32-bit bits/s field, so 5 Gb/s reads 705 Mb/s; show the real
  speed with a note.

Tested in the win11 VM (with and without the BIOS flag, and the late
startnet push).
2026-10-14 16:56:46 -04:00
..