Three fixes from the 579C144 diagnostics, all the same shape: a Display kiosk
being treated as a machine-tool bay.
desktopApps: configuring "none" produced "everything"
"Display-Dashboard": { "desktopApps": [] }
06-OrganizeDesktop.ps1 tested $null -ne $cfgApps -AND .Count -gt 0, so an
explicitly empty list fell through to the hardcoded fallback and the kiosk was
given UDC, eDNC, NTLARS, WJ Shopfloor and Defect_Tracker shortcuts.
Get-ProfileValue returns $null only when the key is ABSENT from both the profile
and site-config, so $null is the real "not configured" signal and an empty array
means what it says. startupItems carried the same test - harmless today because
its else branch has no fallback list, but commented so the two cannot drift.
Machine-number prompt on a machine with no machine number
Register-CheckMachineNumberTask.ps1 armed 'Prompt Machine Number' (AtLogOn,
BUILTIN\Users) whenever the number was the 9999 placeholder - which is always
true on a Display, because startnet only collects a real number for machine-tool
types. A logon dialog on a kiosk with no keyboard. Now skips PC types that have
no machine number by design, and clears any stale task.
S: mapper on a share-less PC
Displays are Entra-joined with local accounts and no SFLD credentials, so mapping
S: can only fail, once per logon, forever. Run-ShopfloorSetup already gated the
CALL on $noEnforceTypes, but the bay registered it anyway at 15:07:55 with no
"Skipping" line in the log - so something in the finalization phase reaches the
registrar past that gate. Rather than chase the caller, the registrar now gates
itself and removes a stale Run entry. The call-site gate stays; this makes the
outcome correct regardless of who invokes it.
That bypass is worth understanding separately - the same pattern would defeat any
call-site gate in the finalization phase.
All three parse clean and are deployed byte-identical to the share.
180 lines
8.3 KiB
PowerShell
180 lines
8.3 KiB
PowerShell
# Register-CheckMachineNumberTask.ps1 - Register the two-task machine
|
|
# number flow at imaging time:
|
|
#
|
|
# 1. "Prompt Machine Number" - AtLogOn, BUILTIN\Users, Limited.
|
|
# Shows InputBox + writes new number to a request file, then triggers
|
|
# the SYSTEM task via schtasks /run.
|
|
#
|
|
# 2. "Apply Machine Number" - on-demand only (no trigger), SYSTEM,
|
|
# RunLevel Highest. Reads the request file, calls Update-MachineNumber
|
|
# with full HKLM + ProgramData access, writes a result JSON, removes
|
|
# the request file. No GUI - the Prompt task polls the result file
|
|
# and displays the dialog.
|
|
#
|
|
# Replaces the old single-task design that ran as the logged-in user with
|
|
# pre-granted BUILTIN\Users HKLM ACLs (02-MachineNumberACLs.ps1). That
|
|
# approach was fragile (timing race with eDNC install, silent ACL skip)
|
|
# and a security hole (any user could write to the machine-identity reg
|
|
# key). With SYSTEM doing the actual writes, no ACL grants needed.
|
|
#
|
|
# Idempotent: safe to re-run. Existing tasks are overwritten.
|
|
#
|
|
# File kept named Register-CheckMachineNumberTask.ps1 (rather than
|
|
# Register-MachineNumberTasks.ps1) so Run-ShopfloorSetup's existing
|
|
# discovery doesn't need editing.
|
|
|
|
$ErrorActionPreference = 'Continue'
|
|
|
|
$logDir = 'C:\Logs\SFLD'
|
|
if (-not (Test-Path $logDir)) { New-Item -Path $logDir -ItemType Directory -Force | Out-Null }
|
|
$logFile = Join-Path $logDir 'register-checkmn.log'
|
|
|
|
function Write-RegLog {
|
|
param([string]$Message)
|
|
$line = '[{0}] [INFO] {1}' -f (Get-Date -Format 'yyyy-MM-dd HH:mm:ss'), $Message
|
|
Add-Content -Path $logFile -Value $line -ErrorAction SilentlyContinue
|
|
Write-Host $line
|
|
}
|
|
|
|
Write-RegLog '=== Register-CheckMachineNumberTask start ==='
|
|
|
|
$promptTaskName = 'Prompt Machine Number'
|
|
$applyTaskName = 'Apply Machine Number'
|
|
$oldTaskName = 'Check Machine Number' # legacy, removed below
|
|
|
|
# Clean up the legacy single-task name from prior imaging cycles.
|
|
try {
|
|
if (Get-ScheduledTask -TaskName $oldTaskName -ErrorAction SilentlyContinue) {
|
|
Unregister-ScheduledTask -TaskName $oldTaskName -Confirm:$false -ErrorAction Stop
|
|
Write-RegLog "Unregistered legacy task '$oldTaskName'"
|
|
}
|
|
} catch { Write-RegLog "Could not unregister legacy '$oldTaskName': $_" }
|
|
|
|
# PC types that have no machine number by design. Arming the prompt on these
|
|
# guarantees a dialog nobody can answer: startnet only collects a machine number
|
|
# for the machine-tool types, so everything else is left on the 9999 placeholder
|
|
# and the check below would otherwise fire on every one of them.
|
|
#
|
|
# Observed on 579C144 (a Display) 2026-08-06: PreInstall logged
|
|
# "Machine number: 9999 (default placeholder)" and the logon prompt armed itself
|
|
# on a kiosk with no keyboard.
|
|
$noMachineNumberTypes = @(
|
|
'gea-shopfloor-display'
|
|
)
|
|
$pcTypeFile = 'C:\Enrollment\pc-type.txt'
|
|
$pcType = ''
|
|
if (Test-Path -LiteralPath $pcTypeFile) {
|
|
$pcType = (Get-Content -LiteralPath $pcTypeFile -First 1 -ErrorAction SilentlyContinue)
|
|
if ($pcType) { $pcType = $pcType.Trim() }
|
|
}
|
|
if ($pcType -and ($noMachineNumberTypes -contains $pcType)) {
|
|
Write-RegLog "PC type '$pcType' has no machine number by design. Not registering the prompt."
|
|
foreach ($t in @($promptTaskName, $applyTaskName)) {
|
|
try {
|
|
if (Get-ScheduledTask -TaskName $t -ErrorAction SilentlyContinue) {
|
|
Unregister-ScheduledTask -TaskName $t -Confirm:$false -ErrorAction Stop
|
|
Write-RegLog "Unregistered stale task '$t'"
|
|
}
|
|
} catch {}
|
|
}
|
|
return
|
|
}
|
|
|
|
# Only arm the tasks if the bay was imaged with the 9999 placeholder. If
|
|
# the tech entered a real machine number during PXE imaging it's already
|
|
# in C:\Enrollment\machine-number.txt; no prompt needed on first logon.
|
|
$mnFile = 'C:\Enrollment\machine-number.txt'
|
|
$mnAtImaging = '9999'
|
|
if (Test-Path -LiteralPath $mnFile) {
|
|
$raw = (Get-Content -LiteralPath $mnFile -First 1 -ErrorAction SilentlyContinue)
|
|
if ($raw) { $mnAtImaging = $raw.Trim() }
|
|
}
|
|
Write-RegLog "Imaging-time machine-number.txt = '$mnAtImaging'"
|
|
if ($mnAtImaging -ne '9999') {
|
|
Write-RegLog "Machine number is real ('$mnAtImaging' != 9999). Not registering tasks."
|
|
foreach ($t in @($promptTaskName, $applyTaskName)) {
|
|
try {
|
|
if (Get-ScheduledTask -TaskName $t -ErrorAction SilentlyContinue) {
|
|
Unregister-ScheduledTask -TaskName $t -Confirm:$false -ErrorAction Stop
|
|
Write-RegLog "Unregistered stale task '$t'"
|
|
}
|
|
} catch {}
|
|
}
|
|
Write-RegLog '=== Register-CheckMachineNumberTask end (no-op) ==='
|
|
exit 0
|
|
}
|
|
|
|
# Resolve script paths. Prefer the staged shopfloor-setup tree on C:
|
|
# (where Run-ShopfloorSetup ran from); fall back to the same dir as this
|
|
# Register script if invoked standalone.
|
|
function Resolve-Script {
|
|
param([string]$LeafName)
|
|
$p = Join-Path $PSScriptRoot $LeafName
|
|
if (Test-Path -LiteralPath $p) { return $p }
|
|
$p = "C:\Enrollment\shopfloor-setup\Shopfloor\$LeafName"
|
|
if (Test-Path -LiteralPath $p) { return $p }
|
|
return $null
|
|
}
|
|
|
|
$promptScript = Resolve-Script 'Prompt-MachineNumber.ps1'
|
|
$applyScript = Resolve-Script 'Apply-MachineNumber.ps1'
|
|
if (-not $promptScript) { Write-RegLog "Prompt-MachineNumber.ps1 not found - cannot register"; exit 1 }
|
|
if (-not $applyScript) { Write-RegLog "Apply-MachineNumber.ps1 not found - cannot register"; exit 1 }
|
|
Write-RegLog "Prompt script: $promptScript"
|
|
Write-RegLog "Apply script: $applyScript"
|
|
|
|
# --- Prompt task (user-context, GUI) ---
|
|
try {
|
|
$action = New-ScheduledTaskAction `
|
|
-Execute 'powershell.exe' `
|
|
-Argument "-NoProfile -ExecutionPolicy Bypass -WindowStyle Normal -File `"$promptScript`""
|
|
$trigger = New-ScheduledTaskTrigger -AtLogOn
|
|
# Group SID S-1-5-32-545 = BUILTIN\Users (catches ShopFloor + support/admin
|
|
# users that log in interactively). RunLevel Limited - no elevation; the
|
|
# actual writes happen in the SYSTEM Apply task below.
|
|
$principal = New-ScheduledTaskPrincipal -GroupId 'S-1-5-32-545' -RunLevel Limited
|
|
$settings = New-ScheduledTaskSettingsSet -AllowStartIfOnBatteries -DontStopIfGoingOnBatteries -StartWhenAvailable -ExecutionTimeLimit (New-TimeSpan -Minutes 5)
|
|
Register-ScheduledTask -TaskName $promptTaskName -Action $action -Trigger $trigger -Principal $principal -Settings $settings -Force -ErrorAction Stop | Out-Null
|
|
Write-RegLog "Registered scheduled task '$promptTaskName' (AtLogOn, BUILTIN\Users, Limited)"
|
|
} catch {
|
|
Write-RegLog "FAILED to register '$promptTaskName': $_"
|
|
exit 1
|
|
}
|
|
|
|
# --- Apply task (SYSTEM, on-demand) ---
|
|
try {
|
|
$action = New-ScheduledTaskAction `
|
|
-Execute 'powershell.exe' `
|
|
-Argument "-NoProfile -ExecutionPolicy Bypass -WindowStyle Hidden -File `"$applyScript`""
|
|
# No trigger - the Prompt task starts this via schtasks /run /tn.
|
|
$principal = New-ScheduledTaskPrincipal -UserId 'SYSTEM' -LogonType ServiceAccount -RunLevel Highest
|
|
$settings = New-ScheduledTaskSettingsSet -AllowStartIfOnBatteries -DontStopIfGoingOnBatteries -StartWhenAvailable -ExecutionTimeLimit (New-TimeSpan -Minutes 10)
|
|
Register-ScheduledTask -TaskName $applyTaskName -Action $action -Principal $principal -Settings $settings -Force -ErrorAction Stop | Out-Null
|
|
Write-RegLog "Registered scheduled task '$applyTaskName' (on-demand, SYSTEM, Highest)"
|
|
|
|
# Default SDDL on a SYSTEM-owned task only grants Admins + SYSTEM
|
|
# FullAccess - BUILTIN\Users can't see or run it via schtasks /run.
|
|
# Add an ACE granting BUILTIN\Users GenericRead + GenericExecute so the
|
|
# user-context Prompt task can trigger this Apply task on demand. They
|
|
# still can't modify/delete it - only read+execute.
|
|
try {
|
|
$svc = New-Object -ComObject Schedule.Service
|
|
$svc.Connect()
|
|
$taskObj = $svc.GetFolder('\').GetTask($applyTaskName)
|
|
# GenericRead = 0x80000000 (GR), GenericExecute = 0x20000000 (GX)
|
|
# BU = BUILTIN\Users
|
|
$newSd = 'O:BAG:BAD:(A;;FA;;;BA)(A;;FA;;;SY)(A;;GRGX;;;BU)'
|
|
# SetSecurityDescriptor flag 0 = default, persists DACL change.
|
|
$taskObj.SetSecurityDescriptor($newSd, 0)
|
|
Write-RegLog "Granted BUILTIN\Users GR+GX on '$applyTaskName' (so Limited users can schtasks /run)"
|
|
} catch {
|
|
Write-RegLog "FAILED to set task SDDL on '$applyTaskName': $_ (Limited users may not be able to trigger Apply)"
|
|
}
|
|
} catch {
|
|
Write-RegLog "FAILED to register '$applyTaskName': $_"
|
|
exit 1
|
|
}
|
|
|
|
Write-RegLog '=== Register-CheckMachineNumberTask end ==='
|
|