Files
pxe-server/playbook/shopfloor-setup/gea-shopfloor-keyence/keyence-manifest.json
cproudlock 6dcf96e40a Phase 3+4 rename reorg: repo dir renames + startnet.cmd menu
Pairs with Phase 1+2 from earlier (alias maps in Install-FromManifest,
GE-Enforce, Get-PCProfile, verify-state). See project-shopfloor-rename-reorg
memory for the plan.

Phase 3 (repo + paths):
- git mv per-PC-type dirs to gea-shopfloor-* names:
    Standard      -> gea-shopfloor-collections
    CMM           -> gea-shopfloor-cmm
    Keyence       -> gea-shopfloor-keyence
    Genspect      -> gea-shopfloor-genspect
    WaxAndTrace   -> gea-shopfloor-waxtrace
    Display       -> gea-shopfloor-display
    Lab           -> gea-shopfloor-common (folded; Timeclock+Lab merge)
- New gea-shopfloor-nocollections/ (clone of collections sans UDC scripts).
- New gea-shopfloor-heattreat/ (placeholder, README only).
- Move Standard/ntlars-backups/ -> _ntlars-backups/ (per-MN, not per-type).
- Run-ShopfloorSetup.ps1: Resolve-PCTypeDir helper walks alias group when
  the on-disk dir for the current pcType is missing. Set-MachineNumber
  helper-copy gated on collections|nocollections|legacy Standard-Machine.
- Update-MachineNumber.ps1: pcProfiles lookups try gea-shopfloor-collections
  first, fall back to legacy Standard-Machine. PowerShell 5.1 compatible
  (no null-coalesce).

Phase 4 (startnet.cmd menu):
- Choice 3 "GEA Shopfloor" now drills into a 9-item sub-menu instead of
  going straight to enrollment. Sub-cats:
    1. Machine with Collections        -> gea-shopfloor-collections
    2. Machine without Collections     -> gea-shopfloor-nocollections
    3. Common (Timeclock, Lab)         -> gea-shopfloor-common
    4. Keyence                         -> gea-shopfloor-keyence
    5. CMM                             -> gea-shopfloor-cmm
    6. Genspect                        -> gea-shopfloor-genspect
    7. Heattreat                       -> gea-shopfloor-heattreat
    8. Wax and Trace                   -> gea-shopfloor-waxtrace
    9. Display                         -> gea-shopfloor-display
- Office menu (existing 6-option) follows for every sub-cat.
- Machine number prompt only for collections + nocollections.
- pc-subtype.txt + display-type.txt no longer written. PCTYPE is a
  single full string (gea-shopfloor-*); subtype-aware code paths fall
  back to empty and resolve via the alias map.
- CMM bootstrap stage gate switched from "%PCTYPE%"=="CMM" to
  "%PCTYPE%"=="gea-shopfloor-cmm".

Test harness:
- B-enforce/run.sh PCSUBTYPE default changed from "Machine" to "" so
  single-arg invocation matches the new single-string scheme. Two-arg
  legacy form ("Standard Machine") still works via aliasing.
- B-enforce/tamper.ps1 alias-aware Test-MatrixEntryMatches mirroring
  verify-state.ps1.

Smoke-tested on win11 VM as SYSTEM via qga: B-enforce harness 5-phase
cycle (stage / baseline / tamper / heal / idempotent) passes 10/10
with PCType=gea-shopfloor-collections AND with legacy "Standard Machine"
two-arg form.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-04 08:09:16 -04:00

26 lines
2.2 KiB
JSON

{
"Version": "1.0",
"_comment": "Keyence machine-app manifest, imaging-time only. Consumed by 09-Setup-Keyence.ps1, reading from the in-repo shopfloor-setup/Keyence/ dir xcopied by startnet.cmd. Ongoing enforcement is handled separately by GE-Enforce reading keyence/manifest.json from the tsgwp00525 share. Each entry has an InstallerRoot-relative 'Installer' path plus standard detection. The 'Type' field is MSI, EXE, or INF: INF invokes pnputil /add-driver /install. When releasing a new VR-6000 version, update the Installer path + DetectionValue here AND on the share manifest.",
"Applications": [
{
"_comment": "VR-6000 Series Software - main Keyence microscope/profilometer control app. Extracted from Keyence6000.exe (Inno Setup wrapper around an InstallShield 2019 MSI). Silent install works fine with /qn + REBOOT=ReallySuppress as long as you bypass the Inno wrapper - the wrapper's [Run] entry calls the bundled InstallShield Setup.exe without silent flags which hangs in session 0.",
"Name": "VR-6000 Series Software",
"Installer": "installers\\VR-6000 Series Software.msi",
"Type": "MSI",
"InstallArgs": "/qn /norestart ALLUSERS=1 REBOOT=ReallySuppress",
"DetectionMethod": "Registry",
"DetectionPath": "HKLM:\\SOFTWARE\\Microsoft\\Windows\\CurrentVersion\\Uninstall\\{058E7194-BDF8-4FA2-9D69-978BB0F25214}",
"DetectionName": "DisplayVersion",
"DetectionValue": "4.3.7"
},
{
"_comment": "KEYENCE VR Series USB driver (WinUSB-based). Pulled from DriverStore after a full interactive install because dpinst.exe in the Inno wrapper needs GUI confirmation. pnputil /add-driver /install stages the INF + cat + co-installer DLLs to the Windows DriverStore; if a physical VR device is plugged in, Windows binds it immediately. Detection checks 'pnputil /enum-drivers' output for the INF filename - this matches regardless of driver version so updates (new INF with same basename) won't false-skip.",
"Name": "KEYENCE VR Series USB Driver",
"Installer": "drivers\\keyence_vr_series.inf",
"Type": "INF",
"DetectionMethod": "pnputil",
"DetectionPattern": "keyence_vr_series\\.inf"
}
]
}